Literature DB >> 17514393

Exploring new technologies to facilitate laparoscopic surgery: creating intestinal anastomoses without sutures or staples, using a radio-frequency-energy-driven bipolar fusion device.

J F Smulders1, I H J T de Hingh, J Stavast, J J Jackimowicz.   

Abstract

INTRODUCTION: Intestinal anastomotic healing requires apposition of the collagen containing submucosal layers of the opposing intestinal walls, which is traditionally achieved by staples or sutures. Recently, a feedback-controlled bipolar sealing system (LigaSure) has been successfully introduced to seal and transect vessels. Since this technology depends on fusion of collagen fibres which are abundantly present in the intestinal wall, the possibility to create intestinal anastomoses using this technology was investigated in the present study.
MATERIALS AND METHODS: For this purpose a new-generation radiofrequency (RF) generator and a prototype of the Ligasure Anastomotic Device (LAD) have been developed. The generator incorporates a closed loop control system which monitors tissue fusion, compares it with a mathematical model of ideal fusion based on the density and compliance of intestinal tissue and adjusts energy output accordingly. In total 8 anastomoses were created in a porcine model (4 pigs, 2 anastomoses each) and healing was assessed by macroscopic and histological examination.
RESULTS: All seals were macroscopic intact both immediate after creation and at sacrifice at the 7th postoperative day. Between operations, pigs appeared healthy and had normal intestinal passage. Histological examination of the anastomoses revealed undisturbed healing with granulation tissue, newly synthesised collagen in the submucosa and re-epithelialization at the borders of the seals.
CONCLUSION: These results confirm the feasibility to create experimental intestinal anastomoses using LigaSure technology. This may be an important step towards the development of new laparoscopic equipment combining dissecting and reconstructive properties within one single instrument.

Entities:  

Mesh:

Year:  2007        PMID: 17514393     DOI: 10.1007/s00464-007-9330-9

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  20 in total

1.  Comparison of thermal spread after ureteral ligation with the Laparo-Sonic ultrasonic shears and the Ligasure system.

Authors:  Sharon L Goldstein; Kristi L Harold; Alan Lentzner; Brent D Matthews; Kent W Kercher; Ronald F Sing; Broc Pratt; Edward H Lipford; B Todd Heniford
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2002-02       Impact factor: 1.878

2.  A novel technique for parenchymal division during hepatectomy.

Authors:  P G Horgan
Journal:  Am J Surg       Date:  2001-03       Impact factor: 2.565

3.  Randomized clinical trial of stapled hemorrhoidectomy vs open with Ligasure for prolapsed piles.

Authors:  G Basdanis; V N Papadopoulos; A Michalopoulos; S Apostolidis; N Harlaftis
Journal:  Surg Endosc       Date:  2004-12-02       Impact factor: 4.584

4.  Hepatic surgery using the Ligasure vessel sealing system.

Authors:  Fabrizio Romano; Claudio Franciosi; Roberto Caprotti; Fabio Uggeri; Franco Uggeri
Journal:  World J Surg       Date:  2005-01       Impact factor: 3.352

5.  Use of an electrothermal bipolar tissue sealing system in lung surgery.

Authors:  Mario Santini; Giovanni Vicidomini; Alfonso Baldi; Giuseppe Gallo; Paolo Laperuta; Luigi Busiello; Maria Pia Di Marino; Vincenzo Pastore
Journal:  Eur J Cardiothorac Surg       Date:  2006-01-11       Impact factor: 4.191

6.  Energy sources for laparoscopic colectomy: a prospective randomized comparison of conventional electrosurgery, bipolar computer-controlled electrosurgery and ultrasonic dissection. Operative outcome and costs analysis.

Authors:  Eduardo Ma Targarona; Carmen Balague; Juan Marin; Rene Berindoague Neto; Carmen Martinez; Jordi Garriga; Manuel Trias
Journal:  Surg Innov       Date:  2005-12       Impact factor: 2.058

7.  Changes of the extracellular matrix as a risk factor for anastomotic leakage after large bowel surgery.

Authors:  Michael Stumpf; Uwe Klinge; Arnulf Wilms; Robert Zabrocki; Rafael Rosch; Karsten Junge; Carsten Krones; Volker Schumpelick
Journal:  Surgery       Date:  2005-02       Impact factor: 3.982

8.  Comparative study of electrothermal bipolar vessel sealer and ultrasonic coagulating shears in laparoscopic colectomy.

Authors:  M Takada; T Ichihara; Y Kuroda
Journal:  Surg Endosc       Date:  2004-12-02       Impact factor: 4.584

9.  Laparoscopic appendectomy using the LigaSure Vessel Sealing System.

Authors:  Horng-Ren Yang; Yu-Chun Wang; Ping-Kuei Chung; Long-Bin Jeng; Ray-Jade Chen
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2005-08       Impact factor: 1.878

10.  A new tissue-sealing technique using the Ligasure system for nonanatomical pulmonary resection: preliminary results of sutureless and stapleless thoracoscopic surgery.

Authors:  Norihisa Shigemura; Akinori Akashi; Tomoyuki Nakagiri; Mitsunori Ohta; Hikaru Matsuda
Journal:  Ann Thorac Surg       Date:  2004-04       Impact factor: 4.330

View more
  18 in total

Review 1.  Surgical Efficacy Among Laparoscopic Ultrasonic Dissectors: Are We Advancing Safely? A Review of Literature.

Authors:  Rajesh Devassy; Sreelatha Gopalakrishnan; Rudy Leon De Wilde
Journal:  J Obstet Gynaecol India       Date:  2015-09-14

2.  Thermal spread and heat absorbance differences between open and laparoscopic surgeries during energized dissections by electrosurgical instruments.

Authors:  C Song; B Tang; P A Campbell; A Cuschieri
Journal:  Surg Endosc       Date:  2009-03-19       Impact factor: 4.584

3.  Use of the LigaSure device and the Stapler for closure of the small bowel: a comparative ex vivo study.

Authors:  Mario Santini; Alfonso Fiorelli; Gaetana Messina; Paolo Laperuta; Antonio Mazzella; Marina Accardo
Journal:  Surg Today       Date:  2012-09-15       Impact factor: 2.549

4.  Colorectal anastomosis facilitated by the use of the LigaSure(®) sealing device: comparative study in an animal model.

Authors:  Francisco Sánchez-De Pedro; Carlos Moreno-Sanz; Antonio Morandeira-Rivas; Jose María Tenías-Burillo; Cristina Alhambra-Rodríguez De Guzmán
Journal:  Surg Endosc       Date:  2013-09-20       Impact factor: 4.584

5.  Use of a bipolar sealing device to seal partial cystectomy with and without augmentation with a single-layer simple continuous suture pattern in an ex vivo canine model.

Authors:  Valery F Scharf; Milan Milovancev; Katy L Townsend; Jennifer A Luff
Journal:  Vet Surg       Date:  2020-05-09       Impact factor: 1.495

6.  LigaSure compared with ligatures and endoclips in experimental appendectomy: how safe is it?

Authors:  Levent Elemen; Yusufhan Yazir; Melih Tugay; Alper Akay; Seval Aydin; Karolin Yanar; Süreyya Ceylan
Journal:  Pediatr Surg Int       Date:  2010-02-07       Impact factor: 1.827

7.  LAPAROSCOPICALLY ASSISTED ANORECTOPLASTY AND THE USE OF THE BIPOLAR DEVICE TO SEAL THE RECTAL URINARY FISTULA.

Authors:  Robson Azevedo Dutra; Adriana Cartafina Perez Boscollo
Journal:  Arq Bras Cir Dig       Date:  2016 Jul-Sep

Review 8.  Common uses and cited complications of energy in surgery.

Authors:  Ganesh Sankaranarayanan; Rajeswara R Resapu; Daniel B Jones; Steven Schwaitzberg; Suvranu De
Journal:  Surg Endosc       Date:  2013-04-23       Impact factor: 4.584

9.  Evaluation of the LigaSure(™) Vessel Sealing System for bowel transection and intestinal anastomosis-an experimental study in a porcine model.

Authors:  Tobias Gehrig; A T Billeter; A L Wekerle; M Shevchenko; K Brand; B P Müller-Stich
Journal:  Langenbecks Arch Surg       Date:  2016-03-23       Impact factor: 3.445

10.  Radiofrequency-induced small bowel thermofusion: an ex vivo study of intestinal seal adequacy using mechanical and imaging modalities.

Authors:  Shobhit Arya; Nancy Hadjievangelou; Su Lei; Hiromi Kudo; Robert D Goldin; Ara W Darzi; Daniel S Elson; George B Hanna
Journal:  Surg Endosc       Date:  2013-04-10       Impact factor: 4.584

View more