Literature DB >> 22844033

Assessment of paediatric CT dose indicators for the purpose of optimisation.

Z Brady1, F Ramanauskas, T M Cain, P N Johnston.   

Abstract

OBJECTIVES: To establish local diagnostic reference levels (LDRLs) at the Royal Children's Hospital (RCH) Melbourne, Parkville, Australia, for typical paediatric CT examinations and compare these with international diagnostic reference levels (DRLs) to benchmark local practice. In addition, the aim was to develop a method of analysing local scan parameters to enable identification of areas for optimisation.
METHODS: A retrospective audit of patient records for paediatric CT brain, chest and abdomen/pelvis examinations was undertaken. Demographic information, examination parameters and dose indicators--volumetric CT dose index (CTDI(vol)) and dose-length product (DLP)--were collected for 220 patients. LDRLs were derived from mean survey values and the effective dose was estimated from DLP values. The normalised CTDI(vol) values, mAs values and scan length were analysed to better identify parameters that could be optimised.
RESULTS: The LDRLs across all age categories were 18-45 mGy (CTDI(vol)) and 250-700 mGy cm (DLP) for brain examinations; 3-23 mGy (CTDI(vol)) and 100-800 mGy cm (DLP) for chest examinations; and 4-15 mGy (CTDI(vol)) and 150-750 mGy cm (DLP) for abdomen/pelvis examinations. Effective dose estimates were 1.0-1.6 mSv, 1.8-13.0 mSv and 2.5-10.0 mSv for brain, chest and abdomen/pelvis examinations, respectively.
CONCLUSION: The RCH mean CTDI(vol) and DLP values are similar to or lower than international DRLs. Use of low-kilovoltage protocols for body imaging in younger patients reduced the dose considerably. There exists potential for optimisation in reducing body scan lengths and justifying the selection of reference mAs values. The assessment method used here proved useful for identifying specific parameters for optimisation. Advances in knowledge Assessment of individual CT parameters in addition to comparison with DRLs enables identification of specific areas for CT optimisation.

Entities:  

Mesh:

Year:  2012        PMID: 22844033      PMCID: PMC3500792          DOI: 10.1259/bjr/28015185

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  32 in total

1.  Diagnostic reference levels in medical imaging: review and additional advice.

Authors: 
Journal:  Ann ICRP       Date:  2001

2.  Dose reduction in pediatric CT: a rational approach.

Authors:  John M Boone; Estella M Geraghty; J Anthony Seibert; Sandra L Wootton-Gorges
Journal:  Radiology       Date:  2003-08       Impact factor: 11.105

3.  1990 Recommendations of the International Commission on Radiological Protection.

Authors: 
Journal:  Ann ICRP       Date:  1991

4.  Patient dose reduction in CT.

Authors:  M A Lewis; S Edyvean
Journal:  Br J Radiol       Date:  2005-10       Impact factor: 3.039

5.  Radiological protection and safety in medicine. A report of the International Commission on Radiological Protection.

Authors: 
Journal:  Ann ICRP       Date:  1996

6.  Estimation of effective doses to adult and pediatric patients from multislice computed tomography: A method based on energy imparted.

Authors:  Nicholas Theocharopoulos; John Damilakis; Kostas Perisinakis; Antonis Tzedakis; Apostolos Karantanas; Nicholas Gourtsoyiannis
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

7.  Patient doses in multi-slice CT and the importance of optimisation.

Authors:  J C P Heggie
Journal:  Australas Phys Eng Sci Med       Date:  2005-06       Impact factor: 1.430

8.  Paediatric and adult computed tomography practice and patient dose in Australia.

Authors:  M Moss; D McLean
Journal:  Australas Radiol       Date:  2006-02

9.  CT doses in children: a multicentre study.

Authors:  J Pages; N Buls; M Osteaux
Journal:  Br J Radiol       Date:  2003-11       Impact factor: 3.039

10.  CT scanning: a major source of radiation exposure.

Authors:  Philip W Wiest; Julie A Locken; Philip H Heintz; Fred A Mettler
Journal:  Semin Ultrasound CT MR       Date:  2002-10       Impact factor: 1.875

View more
  11 in total

1.  Pediatric imaging in DICER1 syndrome.

Authors:  Marta Tijerin Bueno; Claudia Martínez-Ríos; Alejandro De la Puente Gregorio; Rayan A Ahyad; Anita Villani; Harriet Druker; Kalene van Engelen; Bailey Gallinger; Laura Aronoff; Ronald Grant; David Malkin; Mary-Louise C Greer
Journal:  Pediatr Radiol       Date:  2017-05-04

2.  Patient doses from CT examinations in Turkey.

Authors:  Gökçe Kaan Ataç; Aydın Parmaksız; Tolga İnal; Emine Bulur; Figen Bulgurlu; Tolga Öncü; Sadi Gündoğdu
Journal:  Diagn Interv Radiol       Date:  2015 Sep-Oct       Impact factor: 2.630

3.  An Australian local diagnostic reference level for paediatric whole-body 18F-FDG PET/CT.

Authors:  Essam Mohammed Alkhybari; Mark F McEntee; Kathy P Willowson; Patrick C Brennan; Theo Kitsos; Peter L Kench
Journal:  Br J Radiol       Date:  2019-03-05       Impact factor: 3.039

4.  Paediatric doses during some common X-ray procedures at selected referral hospitals in Tanzania.

Authors:  W Muhogora; W Ngoye; E Byorushengo; F Lwakatare; C Kalambo
Journal:  Radiat Prot Dosimetry       Date:  2015-03-19       Impact factor: 0.972

Review 5.  Whole-body magnetic resonance imaging: techniques and non-oncologic indications.

Authors:  Mary-Louise C Greer
Journal:  Pediatr Radiol       Date:  2018-08-04

6.  Comparison of effective dose and lifetime risk of cancer incidence of CT attenuation correction acquisitions and radiopharmaceutical administration for myocardial perfusion imaging.

Authors:  A K Tootell; K Szczepura; P Hogg
Journal:  Br J Radiol       Date:  2014-07-07       Impact factor: 3.039

7.  Effective radiation doses of CT examinations in Japan: a nationwide questionnaire-based study.

Authors:  Yuta Matsunaga; Ai Kawaguchi; Kenichi Kobayashi; Masanao Kobayashi; Yasuki Asada; Kazuyuki Minami; Shoichi Suzuki; Koichi Chida
Journal:  Br J Radiol       Date:  2015-12-09       Impact factor: 3.039

8.  Dose monitoring in pediatric and young adult head and cervical spine CT studies at two emergency duty departments.

Authors:  Hannele Niiniviita; Timo Kiljunen; Minna Huuskonen; Simo Teperi; Jarmo Kulmala
Journal:  Emerg Radiol       Date:  2017-12-16

Review 9.  Whole-body magnetic resonance imaging of pediatric cancer predisposition syndromes: special considerations, challenges and perspective.

Authors:  Sandra Saade-Lemus; Andrew J Degnan; Michael R Acord; Abhay S Srinivasan; Janet R Reid; Sabah E Servaes; Lisa J States; Sudha A Anupindi
Journal:  Pediatr Radiol       Date:  2019-10-16

10.  Assessment and comparison of radiation dose and image quality in multi-detector CT scanners in non-contrast head and neck examinations.

Authors:  Daryoush Khoramian; Soroush Sistani; Razzagh Abedi Firouzjah
Journal:  Pol J Radiol       Date:  2019-01-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.