Literature DB >> 14623782

CT doses in children: a multicentre study.

J Pages1, N Buls, M Osteaux.   

Abstract

We evaluated examination protocols used for common CT procedures of paediatric patients at different hospitals in Belgium in order to determine whether adjustments related to patient size are made in scanning parameters, and to compare patient doses with proposed reference levels. Three paediatric hospitals and one non-paediatric hospital participated in the study. Weighted CT dose-index (CTDI(w)), dose-length product (DLP) and effective dose (E) were evaluated for three patient ages (1 year, 5 years and 10 years) and three common procedures (brain, thorax and abdomen). CTDI(w) and DLP values higher than the reference levels were found for all types of evaluated examination. E ranged from 0.4 mSv to 2.3 mSv, 1.1 mSv to 6.6 mSv, and 2.3 mSv to 19.9 mSv for brain, thorax and abdomen examinations, respectively. All centres but one adapted their protocols as a function of patient size. However, no common trend in the selection of protocols was observed. Some centres divided the whole range of patient size into only two/three groups by age, while others classified the patients into six groups by weight. It was also observed that some centres used the same mAs for the total range of patient sizes and decreased the pitch factor for small children, which resulted in higher doses. This indicates the importance of careful selection of technical scan parameters. If CT parameters used for paediatric patients are not adjusted on the basis of examination type, age and/or size of the child, then some patients will be exposed to an unnecessarily high radiation dose during CT examinations.

Entities:  

Mesh:

Year:  2003        PMID: 14623782     DOI: 10.1259/bjr/92706933

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  22 in total

1.  Is PET/CT necessary in paediatric oncology? For.

Authors:  Christiane Franzius; Kai Uwe Juergens; Otmar Schober
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-08       Impact factor: 9.236

2.  Rapid, low-cost MR imaging protocol to document central nervous system and sinus abnormalities prior to pediatric hematopoietic stem cell transplantation.

Authors:  Eliane D Leite; Adriana Seber; Felipe G de Barbosa; Valeria C Ginani; Fabianne C Carlesse; Roseane V Gouvea; Victor G Zecchin; Cinthya R Carvalho; Gilberto Szarf; Henrique M Lederman
Journal:  Pediatr Radiol       Date:  2011-02-02

Review 3.  Computed tomographies and cancer risk in children: a literature overview of CT practices, risk estimations and an epidemiologic cohort study proposal.

Authors:  Lucian Krille; Hajo Zeeb; Andreas Jahnen; Peter Mildenberger; Michael Seidenbusch; Karl Schneider; Gerald Weisser; Gael Hammer; Peter Scholz; Maria Blettner
Journal:  Radiat Environ Biophys       Date:  2012-02-05       Impact factor: 1.925

Review 4.  PET/CT in paediatric oncology: indications and pitfalls.

Authors:  Christiane Franzius; Kai Uwe Juergens
Journal:  Pediatr Radiol       Date:  2009-06

5.  Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose.

Authors:  Kwang Nam Jin; Eun-Ah Park; Cheong-Il Shin; Whal Lee; Jin Wook Chung; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2010-01-01       Impact factor: 2.357

6.  Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method.

Authors:  Karen E Thomas; Bo Wang
Journal:  Pediatr Radiol       Date:  2008-04-08

Review 7.  CT utilization--trends and developments beyond the United States' borders.

Authors:  Karen E Thomas
Journal:  Pediatr Radiol       Date:  2011-08-17

8.  CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland.

Authors:  Francis R Verdun; Daniel Gutierrez; John Paul Vader; Abbas Aroua; Leonor Trinidad Alamo-Maestre; François Bochud; François Gudinchet
Journal:  Eur Radiol       Date:  2008-04-04       Impact factor: 5.315

9.  Assessment of paediatric CT dose indicators for the purpose of optimisation.

Authors:  Z Brady; F Ramanauskas; T M Cain; P N Johnston
Journal:  Br J Radiol       Date:  2012-07-27       Impact factor: 3.039

10.  Breast cancer risk 55+ years after irradiation for an enlarged thymus and its implications for early childhood medical irradiation today.

Authors:  M Jacob Adams; Ann Dozier; Roy E Shore; Steven E Lipshultz; Ronald G Schwartz; Louis S Constine; Thomas A Pearson; Marilyn Stovall; Paul Winters; Susan G Fisher
Journal:  Cancer Epidemiol Biomarkers Prev       Date:  2010-01       Impact factor: 4.254

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.