Measurement of the presampling modulation transfer function of film digitizers using a curve fitting technique.

F F Yin1, M L Giger, K Doi.   

Abstract

A curve fitting technique combined with an angulated slit image has been developed for the measurement of the presampling modulation transfer function (MTF) of film digitizers. The noisy line spread functions (LSFs) acquired from an angulated slit image are fitted using a combination of two functions by means of a nonlinear least-square fitting technique. The parameters in the model function for each LSF are obtained by minimizing the residual root mean square (RMS), and then averaged over all the LSF fittings. The resulting analytical function is representative of the continuous presampled LSF. We have found that a combination of Gaussian and exponential functions provides a good fit to the LSFs obtained with film digitizers. The corresponding analytical Fourier transformation of the model function yields the presampling MTF, without Nyquist frequency limitation. Measurements of spatial resolution properties using this method were performed for two laser scanners and an optical drum scanner.

Mesh:

Year:  1990        PMID: 2280739     DOI: 10.1118/1.596463

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Experimental evaluation of computerised tomography point spread function variability within the field of view: parametric models.

Authors:  S Doré; R E Kearney
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

2.  Applications of direct detection device in transmission electron microscopy.

Authors:  Liang Jin; Anna-Clare Milazzo; Stuart Kleinfelder; Shengdong Li; Philippe Leblanc; Fred Duttweiler; James C Bouwer; Steven T Peltier; Mark H Ellisman; Nguyen-Huu Xuong
Journal:  J Struct Biol       Date:  2007-10-26       Impact factor: 2.867

3.  Singular value description of a digital radiographic detector: theory and measurements.

Authors:  Iacovos S Kyprianou; Aldo Badano; Brandon D Gallas; Kyle J Myers
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

4.  The modulation transfer function and signal-to-noise ratio of different digital filters: a technical approach.

Authors:  D D Brüllmann; B d'Hoedt
Journal:  Dentomaxillofac Radiol       Date:  2011-05       Impact factor: 2.419

5.  Accurate MTF measurement in digital radiography using noise response.

Authors:  Andrew Kuhls-Gilcrist; Amit Jain; Daniel R Bednarek; Kenneth R Hoffmann; Stephen Rudin
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

6.  Application of a variable filter for presampled modulation transfer function analysis with the edge method.

Authors:  Ryo Higashide; Katsuhiro Ichikawa; Hiroshi Kunitomo; Kazuya Ohashi
Journal:  Radiol Phys Technol       Date:  2015-06-19

7.  Impact of flat panel-imager veiling glare on scatter-estimation accuracy and image quality of a commercial on-board cone-beam CT imaging system.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

8.  The effects of x-ray beam hardening on detective quantum efficiency and radiation dose.

Authors:  Molly Donovan Wong; Xizeng Wu; Hong Liu
Journal:  J Xray Sci Technol       Date:  2011       Impact factor: 1.535

9.  An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: Impact of field of view on spatial resolution of CT images.

Authors:  Choirul Anam; Toshioh Fujibuchi; Wahyu Setia Budi; Freddy Haryanto; Geoff Dougherty
Journal:  J Appl Clin Med Phys       Date:  2018-10-19       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.