Experimental evaluation of computerised tomography point spread function variability within the field of view: parametric models.

S Doré1, R E Kearney.   

Abstract

The objective of the paper was to validate non-linear parametric models of computerised tomography point spread function (PSF), to investigate the role of model parameters and to verify the effect of different imaging conditions on estimated parameters. These models were then to be used experimentally to estimate the variation of PSF shape within the field of view of a scanner. Two parametric models of the PSF are presented. The Gaussian model is appropriate when PSF values are positive, and the damped cosine model can account for negative values. These models are non-linear and fully two-dimensional and do not assume radial symmetry. The models were fitted to images of a point source. The models accounted for over 99% of the variance in the PSF signal. Errors in modulation transfer function were limited to 5% when the appropriate model was selected. The difference in the blurring characteristics of three image reconstruction filters was well quantified by shape parameters, and position parameters located the PSF with subpixel accuracy. With a point source located 50mm directly above the centre of the field of view, the PSF was found to be anisotropic.

Mesh:

Year:  2004        PMID: 15503958     DOI: 10.1007/bf02347539

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  17 in total

1.  Determination of the presampled MTF in computed tomography.

Authors:  J M Boone
Journal:  Med Phys       Date:  2001-03       Impact factor: 4.071

2.  Image restoration in computed tomography: restoration of experimental CT images.

Authors:  S Rathee; Z J Koles; T R Overton
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

3.  Experimental correlation-based identification of X-ray CT point spread function. Part 2: Simulation and design of input signal.

Authors:  S Doré; R E Kearney; J A De Guise
Journal:  Med Biol Eng Comput       Date:  1997-01       Impact factor: 2.602

4.  High resolution orbital computed tomography.

Authors:  C M Citrin
Journal:  J Comput Assist Tomogr       Date:  1986 Sep-Oct       Impact factor: 1.826

5.  Modulation transfer function of the EMI CT head scanner.

Authors:  C J Bischof; J C Ehrhardt
Journal:  Med Phys       Date:  1977 Mar-Apr       Impact factor: 4.071

6.  The line spread function and modulation transfer function of a computed tomographic scanner.

Authors:  P F Judy
Journal:  Med Phys       Date:  1976 Jul-Aug       Impact factor: 4.071

7.  A simplified approach for modulation transfer function determinations in computed tomography.

Authors:  E L Nickoloff; R Riley
Journal:  Med Phys       Date:  1985 Jul-Aug       Impact factor: 4.071

8.  Theoretical resolution of computed tomography systems.

Authors:  G H Glover; R L Eisner
Journal:  J Comput Assist Tomogr       Date:  1979-02       Impact factor: 1.826

9.  X-ray computed tomography in the presence of arbitrary symmetrical focal spot intensity distributions.

Authors:  J G Verly
Journal:  Med Phys       Date:  1980 Jan-Feb       Impact factor: 4.071

10.  Correction for collimator width (restoration) in reconstructive X-ray tomography.

Authors:  R N Bracewell
Journal:  J Comput Assist Tomogr       Date:  1977-01       Impact factor: 1.826

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.