[Optimization of the powder application in the Cerec method with environment-friendly propellant systems].

B J Meyer1, W H Mörmann, F Lutz.   

Abstract

This study compared the thickness of powder layers sprayed on Cerec inlay cavity preparations before taking the "optical impression". 6 different powder propellant methods were evaluated. 60 MOD inlay cavities were prepared in vitro in extracted human molars and mounted in phantom-head jaws. 10 clinicians powdered 1 cavity each for each of the 6 methods. The powdered teeth were embedded in acrylic and the preparations sectioned parallel to the cavity floor, mesio-distally and bucco-lingually. The powder layer thickness on the proximo-lateral walls (PLW), cavity floors (CF) and occlusal margins (OM) were measured using a light microscope. The means and SD are: [Table; see text] This study showed that propane-butane propellants were as effective as the fluoridated hydrocarbons. A wet system (5) was good despite the transient surface cooling (-43 degrees C) effect. However, the air-flow system (6) produced acceptable powder layers as well, avoiding any chemical contamination of the room air.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2277979

Source DB:  PubMed          Journal:  Schweiz Monatsschr Zahnmed        ISSN: 0256-2855


  5 in total

1.  Influence of material surface on the scanning error of a powder-free 3D measuring system.

Authors:  Michael Kurz; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2015-03-07       Impact factor: 3.573

2.  Measurement accuracy of alveolar soft tissue contour using a laboratory laser scanner.

Authors:  Daisuke Ueno; Mariko Kobayashi; Kenko Tanaka; Tsuneaki Watanabe; Tetsuro Nakamura; Kazuhiko Ueda; Takatoshi Nagano
Journal:  Odontology       Date:  2017-08-02       Impact factor: 2.634

3.  Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis.

Authors:  Jin-Young Park; So-Yeon Bae; Jae-Jun Lee; Ji-Hwan Kim; Hae-Young Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

4.  Influence of Applied Liquid-Type Scanning-Aid Material on the Accuracy of the Scanned Image: An In Vitro Experiment.

Authors:  Hyun-Su Oh; Young-Jun Lim; Bongju Kim; Won Hyeon Kim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  Materials (Basel)       Date:  2020-04-27       Impact factor: 3.623

5.  Accuracy of digital dental models and three-dimensional printed dental models in linear measurements and Bolton analysis.

Authors:  William Suryajaya; Maria Purbiati; Nada Ismah
Journal:  F1000Res       Date:  2021-03-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.