Literature DB >> 28770415

Measurement accuracy of alveolar soft tissue contour using a laboratory laser scanner.

Daisuke Ueno1, Mariko Kobayashi2, Kenko Tanaka3, Tsuneaki Watanabe2, Tetsuro Nakamura2, Kazuhiko Ueda4, Takatoshi Nagano5.   

Abstract

Steric analysis of morphological changes is important for evaluation of surgical techniques. This study was performed to assess the measurement accuracy of alveolar soft tissue contour with a laboratory laser scanner. The width of the maxillary alveolar soft tissue contour was evaluated in 20 volunteers. Measurement sites were established in the alveolar soft tissue contour of the maxillary incisor and canine areas. Each site was evaluated by direct measurement with a microcaliper for each subject (DMM) and image measurement using a laboratory laser scanner (IMS). The accuracy of measurement methods was evaluated. Additionally, two plaster models obtained from the same subjects were scanned and superimposed, and the nonoverlapping areas were measured. Each measurement method exhibited a strong correlation (r = 0.89). The interclass correlation coefficient (single measure) between examiners was also high for each measurement method (PMM 0.978; IMS 0.997). In the superimposed images of the two plaster models, the distance of the nonoverlapping region was only 0.06 ± 0.08 mm in the labial aspect and 0.07 ± 0.09 mm in the palatal aspect. The image measurement of the scanning data shows high accuracy in evaluation of the alveolar soft tissue contour. This technique is useful for evaluation of chronological changes in the alveolar contour after soft and hard tissue augmentation.

Entities:  

Keywords:  Dimensional measurement accuracy; Laboratory scanner; Laser scanner

Mesh:

Year:  2017        PMID: 28770415     DOI: 10.1007/s10266-017-0315-4

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  21 in total

1.  Thickness of masticatory mucosa.

Authors:  H P Müller; N Schaller; T Eger; A Heinecke
Journal:  J Clin Periodontol       Date:  2000-06       Impact factor: 8.728

2.  Factors affecting the accuracy of elastometric impression materials.

Authors:  S Y Chen; W M Liang; F N Chen
Journal:  J Dent       Date:  2004-11       Impact factor: 4.379

3.  Accuracy of oral mucosal thickness measurements using spiral computed tomography.

Authors:  Daisuke Ueno; Junichi Sato; Chinami Igarashi; Shohei Ikeda; Masayuki Morita; Shinji Shimoda; Takaaki Udagawa; Kazunari Shiozaki; Mariko Kobayashi; Kaoru Kobayashi
Journal:  J Periodontol       Date:  2010-11-12       Impact factor: 6.993

4.  Current status and perspectives of mucogingival soft tissue measurement methods.

Authors:  Valerie Ronay; Philipp Sahrmann; Andreas Bindl; Thomas Attin; Patrick R Schmidlin
Journal:  J Esthet Restor Dent       Date:  2011-05-09       Impact factor: 2.843

5.  An evaluation of a noninvasive method of assessing alveolar bone levels in an experimental model of cleft lip and palate.

Authors:  R B Lawson; M L Jones
Journal:  Cleft Palate Craniofac J       Date:  1998-01

6.  Single implants and buccal bone grafts in the anterior maxilla: measurements of buccal crestal contours in a 6-year prospective clinical study.

Authors:  Torsten Jemt; Ulf Lekholm
Journal:  Clin Implant Dent Relat Res       Date:  2005       Impact factor: 3.932

7.  A new method to assess and measure palatal masticatory mucosa by cone-beam computerized tomography.

Authors:  Maurício Barriviera; Wagner Rodrigues Duarte; Alessandro Lourenço Januário; Jorge Faber; Ana Cristina Barreto Bezerra
Journal:  J Clin Periodontol       Date:  2009-07       Impact factor: 8.728

8.  A new optical method to evaluate three-dimensional volume changes of alveolar contours: a methodological in vitro study.

Authors:  Simone I Windisch; Ronald E Jung; Irena Sailer; Stephan P Studer; Andreas Ender; Christoph H F Hämmerle
Journal:  Clin Oral Implants Res       Date:  2007-06-21       Impact factor: 5.977

9.  In vivo validation of a three-dimensional optical method to document volumetric soft tissue changes of the interdental papilla.

Authors:  Jan Strebel; Andreas Ender; Frank Paqué; Michael Krähenmann; Thomas Attin; Patrick R Schmidlin
Journal:  J Periodontol       Date:  2009-01       Impact factor: 6.993

10.  Thickness of posterior palatal masticatory mucosa: the use of computerized tomography.

Authors:  Ji-Eun Song; Yoo-Jung Um; Chang-Sung Kim; Seong-Ho Choi; Kyoo-Sung Cho; Chong-Kwan Kim; Jung-Kiu Chai; Ui-Won Jung
Journal:  J Periodontol       Date:  2008-03       Impact factor: 6.993

View more
  1 in total

1.  Design of customized soft-tissue substitutes for posterior single-tooth defects: A proof-of-concept in-vitro study.

Authors:  Yue Sun; Tao Yu; Malin Strasding; Xinran Liu; Felix Burkhardt; Birgit Schäfer; Irena Sailer; Dobrila Nesic
Journal:  Clin Oral Implants Res       Date:  2021-10-16       Impact factor: 5.021

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.