Literature DB >> 25743568

Influence of material surface on the scanning error of a powder-free 3D measuring system.

Michael Kurz1, Thomas Attin2, Albert Mehl2.   

Abstract

OBJECTIVES: This study aims to evaluate the accuracy of a powder-free three-dimensional (3D) measuring system (CEREC Omnicam, Sirona), when scanning the surface of a material at different angles. Additionally, the influence of water was investigated.
MATERIALS AND METHODS: Nine different materials were combined with human tooth surface (enamel) to create n = 27 specimens. These materials were: Controls (InCoris TZI and Cerec Guide Bloc), ceramics (Vitablocs® Mark II and IPS Empress CAD), metals (gold and amalgam) and composites (Tetric Ceram, Filtek Supreme A2B and A2E). The highly polished samples were scanned at different angles with and without water. The 216 scans were then analyzed and descriptive statistics were obtained.
RESULTS: The height difference between the tooth and material surfaces, as measured with the 3D scans, ranged from 0.83 μm (±2.58 μm) to -14.79 μm (±3.45 μm), while the scan noise on the materials was between 3.23 μm (±0.79 μm) and 14.24 μm (±6.79 μm) without considering the control groups. Depending on the thickness of the water film, measurement errors in the order of 300-1,600 μm could be observed.
CONCLUSIONS: The inaccuracies between the tooth and material surfaces, as well as the scan noise for the materials, were within the range of error for measurements used for conventional impressions and are therefore negligible. The presence of water, however, greatly affects the scan. CLINICAL RELEVANCE: The tested powder-free 3D measuring system can safely be used to scan different material surfaces without the prior application of a powder, although drying of the surface prior to scanning is highly advisable.

Entities:  

Keywords:  Accuracy; CAD/CAM; Digital workflow; Impression technique; Intraoral scanning

Mesh:

Substances:

Year:  2015        PMID: 25743568     DOI: 10.1007/s00784-015-1440-5

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  32 in total

1.  Influences of composite-composite join on light transmission characteristics of layered resin composites.

Authors:  Kanako Horie; Masatoshi Nakajima; Keiichi Hosaka; Kimisuke Kainose; Azusa Tanaka; Richard M Foxton; Junji Tagami
Journal:  Dent Mater       Date:  2011-11-05       Impact factor: 5.304

2.  Two- and three-dimensional accuracy of dental impression materials: effects of storage time and moisture contamination.

Authors:  Deepa T Chandran; Daryll C Jagger; Robert G Jagger; Michele E Barbour
Journal:  Biomed Mater Eng       Date:  2010       Impact factor: 1.300

3.  Measurement of translucency of tooth enamel and dentin.

Authors:  Bin Yu; Jin-Soo Ahn; Yong-Keun Lee
Journal:  Acta Odontol Scand       Date:  2009       Impact factor: 2.331

4.  Accuracy of impressions obtained with dual-arch trays.

Authors:  Bernd Wöstmann; Peter Rehmann; Markus Balkenhol
Journal:  Int J Prosthodont       Date:  2009 Mar-Apr       Impact factor: 1.681

5.  Digital impression taking with reproducibly high precision.

Authors:  M Ziegler
Journal:  Int J Comput Dent       Date:  2009       Impact factor: 1.883

6.  Differences in color, translucency and fluorescence between flowable and universal resin composites.

Authors:  Bin Yu; Yong-Keun Lee
Journal:  J Dent       Date:  2008-07-14       Impact factor: 4.379

7.  Intraoral optical impression systems--an overview.

Authors:  S Reich; T Vollborn; A Mehl; M Zimmermann
Journal:  Int J Comput Dent       Date:  2013       Impact factor: 1.883

8.  Translucency of varied brand and shade of resin composites.

Authors:  Bin Yu; Yong-Keun Lee
Journal:  Am J Dent       Date:  2008-08       Impact factor: 1.522

9.  Dimensional accuracy and surface detail reproduction of two hydrophilic vinyl polysiloxane impression materials tested under dry, moist, and wet conditions.

Authors:  Cynthia S Petrie; Mary P Walker; Aisling M O'mahony; Paulette Spencer
Journal:  J Prosthet Dent       Date:  2003-10       Impact factor: 3.426

10.  In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions.

Authors:  Andreas Ender; Albert Mehl
Journal:  Quintessence Int       Date:  2015-01       Impact factor: 1.677

View more
  7 in total

1.  Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods.

Authors:  Hai Yen Mai; Hang-Nga Mai; Cheong-Hee Lee; Kyu-Bok Lee; So-Yeun Kim; Jae-Mok Lee; Keun-Woo Lee; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2022-04-27       Impact factor: 1.989

2.  Comparative Evaluation of Marginal Adaptation and Fracture Strength of Different Ceramic Inlays Produced by CEREC Omnicam and Heat-Pressed Technique.

Authors:  F D Oz; S Bolay
Journal:  Int J Dent       Date:  2018-04-26

3.  Influence of Applied Liquid-Type Scanning-Aid Material on the Accuracy of the Scanned Image: An In Vitro Experiment.

Authors:  Hyun-Su Oh; Young-Jun Lim; Bongju Kim; Won Hyeon Kim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  Materials (Basel)       Date:  2020-04-27       Impact factor: 3.623

4.  The Effects of Orthodontic Brackets on the Time and Accuracy of Digital Impression Taking.

Authors:  Hyojin Heo; Minji Kim
Journal:  Int J Environ Res Public Health       Date:  2021-05-16       Impact factor: 3.390

5.  Can Dental Office Lighting Intensity Conditions Influence the Accuracy of Intraoral Scanning?

Authors:  Anca Jivanescu; Andrei-Bogdan Faur; Raul Nicolae Rotar
Journal:  Scanning       Date:  2021-05-27       Impact factor: 1.932

6.  Accuracy of intraoral and extraoral digital data acquisition for dental restorations.

Authors:  Heike Rudolph; Harald Salmen; Matthias Moldan; Katharina Kuhn; Viktor Sichwardt; Bernd Wöstmann; Ralph Gunnar Luthardt
Journal:  J Appl Oral Sci       Date:  2016 Jan-Feb       Impact factor: 2.698

7.  Accuracy on Scanned Images of Full Arch Models with Orthodontic Brackets by Various Intraoral Scanners in the Presence of Artificial Saliva.

Authors:  Jihu Song; Minji Kim
Journal:  Biomed Res Int       Date:  2020-02-27       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.