Literature DB >> 22760930

Specific absorption rate intersubject variability in 7T parallel transmit MRI of the head.

Martijn de Greef1, Ozlem Ipek, Alexander J E Raaijmakers, Johannes Crezee, Cornelis A T van den Berg.   

Abstract

Patient-specific radiofrequency shimming in high-field MRI strengthens the need for online, patient-specific specific absorption rate (SAR) monitoring. Numerical simulation is currently most effective for this purpose but may require a patient-specific dielectric model. To investigate whether a generic model may be combined with a safety factor to account for variation within the population, generic SAR behavior is studied for 7T MRI of the head. For six detailed head models, radiofrequency fields were simulated for an eight-channel parallel transmit array. SAR behavior is studied through comparison of the eigenvalues/eigenvectors of the local Q-matrices. Furthermore, numerical radiofrequency shimming experiments without and with SAR constraints were performed where SAR during optimization was evaluated on a generic model. In both cases, the ability of different generic models to predict actual SAR levels was evaluated. The largest eigenvalue distribution is comparable between models. Radiofrequency shimming without constraints improves the |B +1| homogeneity while the SAR increases substantially. Imposing constraints on SAR during optimization, estimating SAR on a generic model, was effective. A safety factor of 1.4 was found to be sufficient. Generic SAR behavior makes a generic head model a practical alternative to patient-specific models and allows effective |B +1| shimming with SAR constraints.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22760930     DOI: 10.1002/mrm.24378

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

Review 1.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

2.  Numerical and experimental evaluation of RF shimming in the human brain at 9.4 T using a dual-row transmit array.

Authors:  Jens Hoffmann; Gunamony Shajan; Klaus Scheffler; Rolf Pohmann
Journal:  MAGMA       Date:  2013-11-26       Impact factor: 2.310

Review 3.  Implementation of a comprehensive MR safety course for medical students.

Authors:  Steffen Sammet; Christina L Sammet
Journal:  J Magn Reson Imaging       Date:  2015-07-14       Impact factor: 4.813

4.  Complex difference constrained compressed sensing reconstruction for accelerated PRF thermometry with application to MRI-induced RF heating.

Authors:  Zhipeng Cao; Sukhoon Oh; Ricardo Otazo; Christopher T Sica; Mark A Griswold; Christopher M Collins
Journal:  Magn Reson Med       Date:  2014-04-21       Impact factor: 4.668

5.  Parallel transmission RF pulse design with strict temperature constraints.

Authors:  Cem M Deniz; Giuseppe Carluccio; Christopher Collins
Journal:  NMR Biomed       Date:  2017-02-10       Impact factor: 4.044

6.  Measurement of SAR-induced temperature increase in a phantom and in vivo with comparison to numerical simulation.

Authors:  Sukhoon Oh; Yeun-Chul Ryu; Giuseppe Carluccio; Christopher T Sica; Christopher M Collins
Journal:  Magn Reson Med       Date:  2013-06-26       Impact factor: 4.668

Review 7.  Imaging at ultrahigh magnetic fields: History, challenges, and solutions.

Authors:  Kamil Uğurbil
Journal:  Neuroimage       Date:  2017-07-08       Impact factor: 6.556

8.  Statistical simulation of SAR variability with geometric and tissue property changes by using the unscented transform.

Authors:  Yu Shao; Peng Zeng; Shumin Wang
Journal:  Magn Reson Med       Date:  2014-07-15       Impact factor: 4.668

9.  Improved detection of fMRI activation in the cerebellum at 7T with dielectric pads extending the imaging region of a commercial head coil.

Authors:  Manushka V Vaidya; Mariana Lazar; Cem M Deniz; Gillian G Haemer; Gang Chen; Mary Bruno; Daniel K Sodickson; Riccardo Lattanzi; Christopher M Collins
Journal:  J Magn Reson Imaging       Date:  2018-01-21       Impact factor: 4.813

Review 10.  Magnetic resonance safety.

Authors:  Steffen Sammet
Journal:  Abdom Radiol (NY)       Date:  2016-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.