Metal artifact reduction strategies for improved attenuation correction in hybrid PET/CT imaging.

Mehrsima Abdoli1, Rudi A J O Dierckx, Habib Zaidi.   

Abstract

Metallic implants are known to generate bright and dark streaking artifacts in x-ray computed tomography (CT) images, which in turn propagate to corresponding functional positron emission tomography (PET) images during the CT-based attenuation correction procedure commonly used on hybrid clinical PET/CT scanners. Therefore, visual artifacts and overestimation and/or underestimation of the tracer uptake in regions adjacent to metallic implants are likely to occur and as such, inaccurate quantification of the tracer uptake and potential erroneous clinical interpretation of PET images is expected. Accurate quantification of PET data requires metal artifact reduction (MAR) of the CT images prior to the application of the CT-based attenuation correction procedure. In this review, the origins of metallic artifacts and their impact on clinical PET/CT imaging are discussed. Moreover, a brief overview of proposed MAR methods and their advantages and drawbacks is presented. Although most of the presented MAR methods are mainly developed for diagnostic CT imaging, their potential application in PET/CT imaging is highlighted. The challenges associated with comparative evaluation of these methods in a clinical environment in the absence of a gold standard are also discussed.
© 2012 American Association of Physicists in Medicine.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22755716     DOI: 10.1118/1.4709599

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  The role of 18F-FDG PET/CT in the detection of osteosarcoma recurrence.

Authors:  Andrea Angelini; Francesco Ceci; Paolo Castellucci; Tiziano Graziani; Giulia Polverari; Giulia Trovarelli; Emanuela Palmerini; Stefano Ferrari; Stefano Fanti; Pietro Ruggieri
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-04-12       Impact factor: 9.236

2.  Evaluation of a commercial orthopaedic metal artefact reduction tool in radiation therapy of patients with head and neck cancer.

Authors:  H Kwon; K S Kim; Y M Chun; H-G Wu; J N K Carlson; J M Park; J-I Kim
Journal:  Br J Radiol       Date:  2015-05-20       Impact factor: 3.039

3.  Improving image quality for digital breast tomosynthesis: an automated detection and diffusion-based method for metal artifact reduction.

Authors:  Yao Lu; Heang-Ping Chan; Jun Wei; Lubomir M Hadjiiski; Ravi K Samala
Journal:  Phys Med Biol       Date:  2017-09-15       Impact factor: 3.609

4.  The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants: a phantom study.

Authors:  Roy Harnish; Sven Prevrhal; Abass Alavi; Habib Zaidi; Thomas F Lang
Journal:  Ann Nucl Med       Date:  2014-04-08       Impact factor: 2.668

5.  DuDoDR-Net: Dual-domain data consistent recurrent network for simultaneous sparse view and metal artifact reduction in computed tomography.

Authors:  Bo Zhou; Xiongchao Chen; S Kevin Zhou; James S Duncan; Chi Liu
Journal:  Med Image Anal       Date:  2021-10-29       Impact factor: 8.545

6.  Correlation of PUV and SUV in the extremities while using PEM as a high-resolution positron emission scanner.

Authors:  Sania Rahim; Osama Mawlawi; Patricia Fox; Shree Taylor; Richelle Millican; Nancy M Swanston; J Elliott Brown; Eric M Rohren
Journal:  Skeletal Radiol       Date:  2014-01-16       Impact factor: 2.199

7.  Diagnostic accuracy of 18F-FDG PET/CT for detecting recurrence in patients with primary skeletal Ewing sarcoma.

Authors:  Punit Sharma; Bangkim Chandra Khangembam; K C Sudhir Suman; Harmandeep Singh; Sishir Rastogi; Shah Alam Khan; Sameer Bakhshi; Sanjay Thulkar; Chandrasekhar Bal; Arun Malhotra; Rakesh Kumar
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-04-05       Impact factor: 9.236

8.  Transmission imaging for integrated PET-MR systems.

Authors:  Spencer L Bowen; Niccolò Fuin; Michael A Levine; Ciprian Catana
Journal:  Phys Med Biol       Date:  2016-07-06       Impact factor: 3.609

9.  Value of CT iterative metal artifact reduction in PET/CT-clinical evaluation in 100 patients.

Authors:  Christian Philipp Reinert; Christian la Fougère; Konstantin Nikolaou; Christina Pfannenberg; Sergios Gatidis
Journal:  Br J Radiol       Date:  2019-01-14       Impact factor: 3.039

Review 10.  Pitfalls on PET/CT Due to Artifacts and Instrumentation.

Authors:  Yu-Jung Tsai; Chi Liu
Journal:  Semin Nucl Med       Date:  2021-07-07       Impact factor: 4.446

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.