Transmission imaging for integrated PET-MR systems.

Spencer L Bowen1, Niccolò Fuin, Michael A Levine, Ciprian Catana.   

Abstract

Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method's performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with (18)F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm(-1) was recorded for an experimental uniform cylinder phantom scan, while a bias of  <2% was measured for the cortical bone equivalent insert of the multi-compartment phantom. Single torus μ-maps of a hip implant phantom showed significantly less artifacts and improved dynamic range, and differed greatly for highly attenuating materials in the case of the patient table, compared to CT results. Use of a fixed torus geometry, in combination with translation of the patient table to perform complete tomographic sampling, generated highly quantitative measured μ-maps and is expected to produce images with significantly higher SNR than competing fixed geometries at matched total acquisition time.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27384608      PMCID: PMC5004490          DOI: 10.1088/0031-9155/61/15/5547

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  42 in total

Review 1.  X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

Authors:  Paul E Kinahan; Bruce H Hasegawa; Thomas Beyer
Journal:  Semin Nucl Med       Date:  2003-07       Impact factor: 4.446

2.  Fast Patch-Based Pseudo-CT Synthesis from T1-Weighted MR Images for PET/MR Attenuation Correction in Brain Studies.

Authors:  Angel Torrado-Carvajal; Joaquin L Herraiz; Eduardo Alcain; Antonio S Montemayor; Lina Garcia-Cañamaque; Juan A Hernandez-Tamames; Yves Rozenholc; Norberto Malpica
Journal:  J Nucl Med       Date:  2015-10-22       Impact factor: 10.057

3.  An analytical scatter correction for singles-mode transmission data in PET.

Authors:  Eric Vandervoort; Vesna Sossi
Journal:  IEEE Trans Med Imaging       Date:  2008-03       Impact factor: 10.048

Review 4.  Transmission scanning in emission tomography.

Authors:  D L Bailey
Journal:  Eur J Nucl Med       Date:  1998-07

5.  MR-Based PET attenuation correction for PET/MR imaging.

Authors:  Ilja Bezrukov; Frédéric Mantlik; Holger Schmidt; Bernhard Schölkopf; Bernd J Pichler
Journal:  Semin Nucl Med       Date:  2013-01       Impact factor: 4.446

6.  Comparison of whole-body PET/CT and PET/MRI in breast cancer patients: lesion detection and quantitation of 18F-deoxyglucose uptake in lesions and in normal organ tissues.

Authors:  Leonardo Pace; Emanuele Nicolai; Angelo Luongo; Marco Aiello; Onofrio A Catalano; Andrea Soricelli; Marco Salvatore
Journal:  Eur J Radiol       Date:  2013-11-23       Impact factor: 3.528

7.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

8.  Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.

Authors:  Ciprian Catana; Andre van der Kouwe; Thomas Benner; Christian J Michel; Michael Hamm; Matthias Fenchel; Bruce Fischl; Bruce Rosen; Matthias Schmand; A Gregory Sorensen
Journal:  J Nucl Med       Date:  2010-09       Impact factor: 10.057

9.  Whole-Body PET/MR Imaging: Quantitative Evaluation of a Novel Model-Based MR Attenuation Correction Method Including Bone.

Authors:  Daniel H Paulus; Harald H Quick; Christian Geppert; Matthias Fenchel; Yiqiang Zhan; Gerardo Hermosillo; David Faul; Fernando Boada; Kent P Friedman; Thomas Koesters
Journal:  J Nucl Med       Date:  2015-05-29       Impact factor: 10.057

10.  PET/CT: comparison of quantitative tracer uptake between germanium and CT transmission attenuation-corrected images.

Authors:  Yuji Nakamoto; Medhat Osman; Christian Cohade; Laura T Marshall; Jonathan M Links; Steve Kohlmyer; Richard L Wahl
Journal:  J Nucl Med       Date:  2002-09       Impact factor: 10.057

View more
  5 in total

1.  PET/MRI in the Presence of Metal Implants: Completion of the Attenuation Map from PET Emission Data.

Authors:  Niccolo Fuin; Stefano Pedemonte; Onofrio A Catalano; David Izquierdo-Garcia; Andrea Soricelli; Marco Salvatore; Keith Heberlein; Jacob M Hooker; Koen Van Leemput; Ciprian Catana
Journal:  J Nucl Med       Date:  2017-01-26       Impact factor: 10.057

2.  Intrascanner Reproducibility of an SPM-based Head MR-based Attenuation Correction Method.

Authors:  David Izquierdo-Garcia; Mark C Eldaief; Mark G Vangel; Ciprian Catana
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-09-06

3.  Technical note: A PET/MR coil with an integrated, orbiting 511 keV transmission source for PET/MR imaging validated in an animal study.

Authors:  Andreas Renner; Ivo Rausch; Jacobo Cal Gonzalez; Elmar Laistler; Ewald Moser; Thies Jochimsen; Tatjana Sattler; Osama Sabri; Thomas Beyer; Michael Figl; Wolfgang Birkfellner; Bernhard Sattler
Journal:  Med Phys       Date:  2022-03-08       Impact factor: 4.506

Review 4.  PET/MRI attenuation estimation in the lung: A review of past, present, and potential techniques.

Authors:  Joseph Lillington; Ludovica Brusaferri; Kerstin Kläser; Karin Shmueli; Radhouene Neji; Brian F Hutton; Francesco Fraioli; Simon Arridge; Manuel Jorge Cardoso; Sebastien Ourselin; Kris Thielemans; David Atkinson
Journal:  Med Phys       Date:  2020-01-01       Impact factor: 4.071

5.  A Path to Qualification of PET/MRI Scanners for Multicenter Brain Imaging Studies: Evaluation of MRI-Based Attenuation Correction Methods Using a Patient Phantom.

Authors:  Ciprian Catana; Richard Laforest; Hongyu An; Fernando Boada; Tuoyu Cao; David Faul; Bjoern Jakoby; Floris P Jansen; Bradley J Kemp; Paul E Kinahan; Peder Larson; Michael A Levine; Piotr Maniawski; Osama Mawlawi; Jonathan E McConathy; Alan B McMillan; Julie C Price; Abhejit Rajagopal; John Sunderland; Patrick Veit-Haibach; Kristen A Wangerin; Chunwei Ying; Thomas A Hope
Journal:  J Nucl Med       Date:  2021-07-22       Impact factor: 11.082

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.