Literature DB >> 19622855

4D CT sorting based on patient internal anatomy.

Ruijiang Li1, John H Lewis, Laura I Cerviño, Steve B Jiang.   

Abstract

Respiratory motion during free-breathing computed tomography (CT) scan may cause significant errors in target definition for tumors in the thorax and upper abdomen. A four-dimensional (4D) CT technique has been widely used for treatment simulation of thoracic and abdominal cancer radiotherapy. The current 4D CT techniques require retrospective sorting of the reconstructed CT slices oversampled at the same couch position. Most sorting methods depend on external surrogates of respiratory motion recorded by extra instruments. However, respiratory signals obtained from these external surrogates may not always accurately represent the internal target motion, especially when irregular breathing patterns occur. We have proposed a new sorting method based on multiple internal anatomical features for multi-slice CT scan acquired in the cine mode. Four features are analyzed in this study, including the air content, lung area, lung density and body area. We use a measure called spatial coherence to select the optimal internal feature at each couch position and to generate the respiratory signals for 4D CT sorting. The proposed method has been evaluated for ten cancer patients (eight with thoracic cancer and two with abdominal cancer). For nine patients, the respiratory signals generated from the combined internal features are well correlated to those from external surrogates recorded by the real-time position management (RPM) system (average correlation: 0.95+/-0.02), which is better than any individual internal measures at 95% confidence level. For these nine patients, the 4D CT images sorted by the combined internal features are almost identical to those sorted by the RPM signal. For one patient with an irregular breathing pattern, the respiratory signals given by the combined internal features do not correlate well with those from RPM (correlation: 0.68+/-0.42). In this case, the 4D CT image sorted by our method presents fewer artifacts than that from the RPM signal. Our 4D CT internal sorting method eliminates the need of externally recorded surrogates of respiratory motion. It is an automatic, accurate, robust, cost efficient and yet simple method and therefore can be readily implemented in clinical settings.

Entities:  

Mesh:

Year:  2009        PMID: 19622855     DOI: 10.1088/0031-9155/54/15/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  31 in total

1.  Reduction of irregular breathing artifacts in respiration-correlated CT images using a respiratory motion model.

Authors:  Agung Hertanto; Qinghui Zhang; Yu-Chi Hu; Oleksandr Dzyubak; Andreas Rimner; Gig S Mageras
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

2.  Reconstruction of four-dimensional computed tomography lung images by applying spatial and temporal anatomical constraints using a Bayesian model.

Authors:  Tiancheng He; Zhong Xue; Bin S Teh; Stephen T Wong
Journal:  J Med Imaging (Bellingham)       Date:  2015-05-13

3.  Adaptation and applications of a realistic digital phantom based on patient lung tumor trajectories.

Authors:  Pankaj Mishra; Sara St James; W Paul Segars; Ross I Berbeco; John H Lewis
Journal:  Phys Med Biol       Date:  2012-06-07       Impact factor: 3.609

4.  Resolution enhancement of lung 4D-CT via group-sparsity.

Authors:  Arnav Bhavsar; Guorong Wu; Jun Lian; Dinggang Shen
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

5.  4D CT lung ventilation images are affected by the 4D CT sorting method.

Authors:  Tokihiro Yamamoto; Sven Kabus; Cristian Lorenz; Eric Johnston; Peter G Maxim; Maximilian Diehn; Neville Eclov; Cristian Barquero; Billy W Loo; Paul J Keall
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

6.  Characterization and identification of spatial artifacts during 4D-CT imaging.

Authors:  Dongfeng Han; John Bayouth; Sudershan Bhatia; Milan Sonka; Xiaodong Wu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

7.  A method for volumetric imaging in radiotherapy using single x-ray projection.

Authors:  Yuan Xu; Hao Yan; Luo Ouyang; Jing Wang; Linghong Zhou; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

8.  Estimating the 4D respiratory lung motion by spatiotemporal registration and super-resolution image reconstruction.

Authors:  Guorong Wu; Qian Wang; Jun Lian; Dinggang Shen
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

9.  Retrospective 4D MR image construction from free-breathing slice Acquisitions: A novel graph-based approach.

Authors:  Yubing Tong; Jayaram K Udupa; Krzysztof C Ciesielski; Caiyun Wu; Joseph M McDonough; David A Mong; Robert M Campbell
Journal:  Med Image Anal       Date:  2016-08-13       Impact factor: 8.545

Review 10.  Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging.

Authors:  Tzu C Lee; Adam M Alessio; Robert M Miyaoka; Paul E Kinahan
Journal:  Q J Nucl Med Mol Imaging       Date:  2015-11-17       Impact factor: 2.346

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.