Literature DB >> 22753678

A receptor-targeted fluorescent radiopharmaceutical for multireporter sentinel lymph node imaging.

Derek K Emerson1, Karl K Limmer, David J Hall, Sung-Ho Han, William C Eckelman, Christopher J Kane, Anne M Wallace, David R Vera.   

Abstract

PURPOSE: To determine the imaging and receptor-binding properties of a multireporter probe designed for sentinel lymph node (SLN) mapping via nuclear and fluorescence detection.
MATERIALS AND METHODS: The animal experiments were approved by the institutional animal care and use committee. A multireporter probe was synthesized by covalently attaching cyanine 7 (Cy7), a near-infrared cyanine dye, to tilmanocept, a radiopharmaceutical that binds to a receptor specific to recticuloendothelial cells. In vitro binding assays of technetium 99m (99mTc)-labeled Cy7 tilmanocept were conducted at 4°C by using receptor-bearing macrophages. Optical SLN imaging after foot pad administration was performed by using two molar doses of Cy7 tilmanocept. Six mice were injected with 0.11 nmol of 99mTc-labeled Cy7 tilmanocept (low-dose group); an additional six mice were injected with 31 nmol of 99mTc-labeled Cy7 tilmanocept (high-dose group) to saturate the receptor sites within the SLN. After 2.5 hours of imaging, the mice were euthanized, and the sentinel and distal lymph nodes were excised and assayed for radioactivity for calculation of SLN percentage of injected dose and extraction. Four mice were used as controls for autofluorescence. Standard optical imaging software was used to plot integrated fluorescence intensity against time for calculation of the SLN uptake rate constant and scaled peak intensity. Significance was calculated by using the Student t test.
RESULTS: In vitro binding assays showed subnanomolar affinity (mean dissociation constant, 0.25 nmol/L±0.10 [standard deviation]). Fluorescence imaging showed a detection sensitivity of 1.6×10(3) counts·sec(-1)·μW(-1) per picomole of Cy7. All four imaging metrics (percentage of injected dose, SLN extraction, SLN uptake rate constant, and expected peak fluorescence intensity) exhibited higher values (P=.005 to P=.042) in the low-dose group than in the high-dose group; this finding was consistent with receptor-mediated image formation.
CONCLUSION: The multireporter probe 99mTc-labeled Cy7 tilmanocept exhibits in vitro and in vivo receptor-binding properties for successful receptor-targeted SLN mapping with nuclear and optical imaging. © RSNA, 2012.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22753678      PMCID: PMC3447170          DOI: 10.1148/radiol.12120638

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  33 in total

Review 1.  Image-guided surgery using invisible near-infrared light: fundamentals of clinical translation.

Authors:  Sylvain Gioux; Hak Soo Choi; John V Frangioni
Journal:  Mol Imaging       Date:  2010-10       Impact factor: 4.488

2.  Cy5.5-DTPA-galactosyl-dextran: a fluorescent probe for in vivo measurement of receptor biochemistry.

Authors:  David R Vera; David J Hall; Carl K Hoh; Pascal Gallant; Laura M McIntosh; Robert F Mattrey
Journal:  Nucl Med Biol       Date:  2005-10       Impact factor: 2.408

3.  Detection rate and operating time required for gamma probe-guided sentinel lymph node resection after injection of technetium-99m nanocolloid into the prostate with and without preoperative imaging.

Authors:  Sebastian H Warncke; Agostino Mattei; Frank G Fuechsel; Sebastian Z'Brun; Thomas Krause; Urs E Studer
Journal:  Eur Urol       Date:  2007-01-22       Impact factor: 20.096

Review 4.  Surgery and sentinel lymph node biopsy.

Authors:  Mark B Faries; Donald L Morton
Journal:  Semin Oncol       Date:  2007-12       Impact factor: 4.929

Review 5.  Lymph node dissection during robot-assisted radical prostatectomy: where do we stand?

Authors:  J L Silberstein; I H Derweesh; C J Kane
Journal:  Prostate Cancer Prostatic Dis       Date:  2009-06-23       Impact factor: 5.554

6.  Lymphoseek: a molecular imaging agent for melanoma sentinel lymph node mapping.

Authors:  Anne M Wallace; Carl K Hoh; Scott J Ellner; Denise D Darrah; Gery Schulteis; David R Vera
Journal:  Ann Surg Oncol       Date:  2006-12-05       Impact factor: 5.344

7.  Histopathologic validation of the sentinel lymph node hypothesis for breast carcinoma.

Authors:  R R Turner; D W Ollila; D L Krasne; A E Giuliano
Journal:  Ann Surg       Date:  1997-09       Impact factor: 12.969

8.  Surgical complications associated with sentinel lymph node dissection (SLND) plus axillary lymph node dissection compared with SLND alone in the American College of Surgeons Oncology Group Trial Z0011.

Authors:  Anthony Lucci; Linda Mackie McCall; Peter D Beitsch; Patrick W Whitworth; Douglas S Reintgen; Peter W Blumencranz; A Marilyn Leitch; Sukumal Saha; Kelly K Hunt; Armando E Giuliano
Journal:  J Clin Oncol       Date:  2007-05-07       Impact factor: 44.544

9.  Sentinel lymph node accumulation of Lymphoseek and Tc-99m-sulfur colloid using a "2-day" protocol.

Authors:  Anne M Wallace; Carl K Hoh; Karl K Limmer; Denise D Darrah; Gery Schulteis; David R Vera
Journal:  Nucl Med Biol       Date:  2009-08       Impact factor: 2.408

10.  The sentinel node in breast cancer--a multicenter validation study.

Authors:  D Krag; D Weaver; T Ashikaga; F Moffat; V S Klimberg; C Shriver; S Feldman; R Kusminsky; M Gadd; J Kuhn; S Harlow; P Beitsch
Journal:  N Engl J Med       Date:  1998-10-01       Impact factor: 91.245

View more
  23 in total

1.  Preoperative sentinel lymph node mapping of the prostate using PET/CT fusion imaging and Ga-68-labeled tilmanocept in an animal model.

Authors:  Sean P Stroup; Christopher J Kane; Salman Farchshchi-Heydari; Claude M James; Christopher H Davis; Anne M Wallace; Carl K Hoh; David R Vera
Journal:  Clin Exp Metastasis       Date:  2012-06-20       Impact factor: 5.150

2.  (68)Ga-labeled superparamagnetic iron oxide nanoparticles (SPIONs) for multi-modality PET/MR/Cherenkov luminescence imaging of sentinel lymph nodes.

Authors:  Renata Madru; Thuy A Tran; Johan Axelsson; Christian Ingvar; Adnan Bibic; Freddy Ståhlberg; Linda Knutsson; Sven-Erik Strand
Journal:  Am J Nucl Med Mol Imaging       Date:  2013-12-15

Review 3.  Image-guided cancer surgery using near-infrared fluorescence.

Authors:  Alexander L Vahrmeijer; Merlijn Hutteman; Joost R van der Vorst; Cornelis J H van de Velde; John V Frangioni
Journal:  Nat Rev Clin Oncol       Date:  2013-07-23       Impact factor: 66.675

4.  Fluorescence-Based Molecular Imaging of Porcine Urinary Bladder Sentinel Lymph Nodes.

Authors:  Hak J Lee; Christopher V Barback; Carl K Hoh; Zhengtao Qin; Kareem Kader; David J Hall; David R Vera; Christopher J Kane
Journal:  J Nucl Med       Date:  2017-02-02       Impact factor: 10.057

5.  Fluorescent-tilmanocept for tumor margin analysis in the mouse model.

Authors:  Ava Hosseini; Jennifer L Baker; Christopher A Tokin; Zhengtao Qin; David J Hall; Dwayne G Stupak; Tomoko Hayashi; Anne M Wallace; David R Vera
Journal:  J Surg Res       Date:  2014-05-10       Impact factor: 2.192

6.  Optimization via specific fluorescence brightness of a receptor-targeted probe for optical imaging and positron emission tomography of sentinel lymph nodes.

Authors:  Zhengtao Qin; David J Hall; Michael A Liss; Carl K Hoh; Christopher J Kane; Anne M Wallace; David R Vera
Journal:  J Biomed Opt       Date:  2013-10       Impact factor: 3.170

7.  Robotic-assisted fluorescence sentinel lymph node mapping using multimodal image guidance in an animal model.

Authors:  Michael A Liss; Sean P Stroup; Zhengtao Qin; Carl K Hoh; David J Hall; David R Vera; Christopher J Kane
Journal:  Urology       Date:  2014-08-16       Impact factor: 2.649

8.  Determination of the surgical margin in laparoscopic liver resections using infrared indocyanine green fluorescence.

Authors:  Takeshi Aoki; Masahiko Murakami; Tomotake Koizumi; Kazuhiro Matsuda; Akira Fujimori; Tomokazu Kusano; Yuta Enami; Satoru Goto; Makoto Watanabe; Koji Otsuka
Journal:  Langenbecks Arch Surg       Date:  2018-06-18       Impact factor: 3.445

9.  68Ga chelating bioorthogonal tetrazine polymers for the multistep labeling of cancer biomarkers.

Authors:  Brandon Nichols; Zhengtao Qin; Jun Yang; David R Vera; Neal K Devaraj
Journal:  Chem Commun (Camb)       Date:  2014-03-04       Impact factor: 6.222

Review 10.  Fluorescence-guided surgery with live molecular navigation--a new cutting edge.

Authors:  Quyen T Nguyen; Roger Y Tsien
Journal:  Nat Rev Cancer       Date:  2013-08-08       Impact factor: 60.716

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.