Literature DB >> 23958947

Optimization via specific fluorescence brightness of a receptor-targeted probe for optical imaging and positron emission tomography of sentinel lymph nodes.

Zhengtao Qin1, David J Hall, Michael A Liss, Carl K Hoh, Christopher J Kane, Anne M Wallace, David R Vera.   

Abstract

The optical properties of a receptor-targeted probe designed for dual-modality mapping of the sentinel lymph node (SLN) was optimized. Specific fluorescence brightness was used as the design criterion, which was defined as the fluorescence brightness per mole of the contrast agent. Adjusting the molar ratio of the coupling reactants, IRDye 800CW-NHS-ester and tilmanocept, enabled us to control the number of fluorescent molecules attached to each tilmanocept, which was quantified by H1 nuclear magnetic resonance spectroscopy. Quantum yields and molar absorptivities were measured for unconjugated IRDye 800CW and IRDye 800CW-tilmanocept (800CW-tilmanocept) preparations at 0.7, 1.5, 2.3, 2.9, and 3.8 dyes per tilmanocept. Specific fluorescence brightness was calculated by multiplication of the quantum yield by the molar absorptivity and the number of dyes per tilmanocept. It predicted that the preparation with 2.3 dyes per tilmanocept would exhibit the brightest signal, which was confirmed by fluorescence intensity measurements using three optical imaging systems. When radiolabeled with Ga68 and injected into the footpads of mice, the probe identified SLNs by both fluorescence and positron emission tomography (PET) while maintaining high percent extraction by the SLN. These studies demonstrated the feasibility of 800CW-tilmanocept for multimodal SLN mapping via fluorescence and PET-computed tomography imaging.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23958947      PMCID: PMC3745642          DOI: 10.1117/1.JBO.18.10.101315

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  30 in total

1.  Interpretation of data obtained in studies with isotope-labeled proteins of biological significance; chemical considerations.

Authors:  J L ONCLEY
Journal:  Fed Proc       Date:  1957-07

2.  Comparing the hybrid fluorescent-radioactive tracer indocyanine green-99mTc-nanocolloid with 99mTc-nanocolloid for sentinel node identification: a validation study using lymphoscintigraphy and SPECT/CT.

Authors:  Oscar R Brouwer; Tessa Buckle; Lenka Vermeeren; W Martin C Klop; Alfons J M Balm; Henk G van der Poel; Bas W van Rhijn; Simon Horenblas; Omgo E Nieweg; Fijs W B van Leeuwen; Renato A Valdés Olmos
Journal:  J Nucl Med       Date:  2012-05-29       Impact factor: 10.057

3.  Cy5.5-DTPA-galactosyl-dextran: a fluorescent probe for in vivo measurement of receptor biochemistry.

Authors:  David R Vera; David J Hall; Carl K Hoh; Pascal Gallant; Laura M McIntosh; Robert F Mattrey
Journal:  Nucl Med Biol       Date:  2005-10       Impact factor: 2.408

Review 4.  True radiotracers: are we approaching theoretical specific activity with Tc-99m and I-123?

Authors:  William C Eckelman; Mauro Bonardi; Wynn A Volkert
Journal:  Nucl Med Biol       Date:  2008-07       Impact factor: 2.408

5.  Kinetic sensitivity of a receptor-binding radiopharmaceutical: technetium-99m galactosyl-neoglycoalbumin.

Authors:  D R Vera; E S Woodle; R C Stadalnik
Journal:  J Nucl Med       Date:  1989-09       Impact factor: 10.057

6.  Quantitative lymphoscintigraphy I: Basic concepts for optimal uptake of radiocolloids in the parasternal lymph nodes of rabbits.

Authors:  S E Strand; B R Persson
Journal:  J Nucl Med       Date:  1979-10       Impact factor: 10.057

7.  Technical details of intraoperative lymphatic mapping for early stage melanoma.

Authors:  D L Morton; D R Wen; J H Wong; J S Economou; L A Cagle; F K Storm; L J Foshag; A J Cochran
Journal:  Arch Surg       Date:  1992-04

8.  Intraoperative laparoscopic fluorescence guidance to the sentinel lymph node in prostate cancer patients: clinical proof of concept of an integrated functional imaging approach using a multimodal tracer.

Authors:  Henk G van der Poel; Tessa Buckle; Oscar R Brouwer; Renato A Valdés Olmos; Fijs W B van Leeuwen
Journal:  Eur Urol       Date:  2011-04-01       Impact factor: 20.096

9.  Intraoperative radio-lympho-scintigraphy improves sentinel lymph node identification for patients with melanoma.

Authors:  J J Albertini; C W Cruse; D Rapaport; K Wells; M Ross; R DeConti; C G Berman; K Jared; J Messina; G Lyman; F Glass; N Fenske; D S Reintgen
Journal:  Ann Surg       Date:  1996-02       Impact factor: 12.969

10.  Lymphoseek: a molecular radiopharmaceutical for sentinel node detection.

Authors:  Anne M Wallace; Carl K Hoh; David R Vera; Denise D Darrah; Gery Schulteis
Journal:  Ann Surg Oncol       Date:  2003-06       Impact factor: 5.344

View more
  9 in total

1.  Fluorescence-Based Molecular Imaging of Porcine Urinary Bladder Sentinel Lymph Nodes.

Authors:  Hak J Lee; Christopher V Barback; Carl K Hoh; Zhengtao Qin; Kareem Kader; David J Hall; David R Vera; Christopher J Kane
Journal:  J Nucl Med       Date:  2017-02-02       Impact factor: 10.057

2.  Preclinical evaluation of robotic-assisted sentinel lymph node fluorescence imaging.

Authors:  Michael A Liss; Salman Farshchi-Heydari; Zhengtao Qin; Sean A Hickey; David J Hall; Christopher J Kane; David R Vera
Journal:  J Nucl Med       Date:  2014-07-14       Impact factor: 10.057

3.  Fluorescent-tilmanocept for tumor margin analysis in the mouse model.

Authors:  Ava Hosseini; Jennifer L Baker; Christopher A Tokin; Zhengtao Qin; David J Hall; Dwayne G Stupak; Tomoko Hayashi; Anne M Wallace; David R Vera
Journal:  J Surg Res       Date:  2014-05-10       Impact factor: 2.192

4.  Robotic-assisted fluorescence sentinel lymph node mapping using multimodal image guidance in an animal model.

Authors:  Michael A Liss; Sean P Stroup; Zhengtao Qin; Carl K Hoh; David J Hall; David R Vera; Christopher J Kane
Journal:  Urology       Date:  2014-08-16       Impact factor: 2.649

Review 5.  Hybrid intraoperative imaging techniques in radioguided surgery: present clinical applications and future outlook.

Authors:  S L Bugby; J E Lees; A C Perkins
Journal:  Clin Transl Imaging       Date:  2017-06-27

6.  Designing a New Molecular Probe: The Potential Role for Tilmanocept (Lymphoseek®) in the Assessment of Patients with Painful Hip and Knee Joint Prostheses.

Authors:  O O Adesanya; C E Hutchinson
Journal:  Open Orthop J       Date:  2017-03-22

7.  Molecular Imaging of the Glomerulus via Mesangial Cell Uptake of Radiolabeled Tilmanocept.

Authors:  Zhengtao Qin; Carl K Hoh; Emilia S Olson; Amin Haghighat Jahromi; David J Hall; Christopher V Barback; Young-Hyun You; Motoko Yanagita; Kumar Sharma; David R Vera
Journal:  J Nucl Med       Date:  2019-02-22       Impact factor: 10.057

8.  Performance of optoacoustic and fluorescence imaging in detecting deep-seated fluorescent agents.

Authors:  Zhenyue Chen; Xosé Luís Deán-Ben; Sven Gottschalk; Daniel Razansky
Journal:  Biomed Opt Express       Date:  2018-04-19       Impact factor: 3.732

9.  Molecular Imaging of endometrial sentinel lymph nodes utilizing fluorescent-labeled Tilmanocept during robotic-assisted surgery in a porcine model.

Authors:  Kristen M Anderson; Christopher V Barback; Zhengtao Qin; David J Hall; Carl K Hoh; David R Vera; Michael T McHale
Journal:  PLoS One       Date:  2018-07-02       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.