Literature DB >> 22752452

Arm circumference: its importance for dialysis patients in the obesity era.

Tekin Akpolat1, Coşkun Kaya, Cengiz Utaş, Turgay Arinsoy, Hülya Taşkapan, Emre Erdem, M Emin Yilmaz, Rezzan Ataman, Semra Bozfakioğlu, Çetin Özener, Ibrahim Karayaylali, Rümeyza Kazancioğlu, Taner Çamsari, Mahmut Yavuz, Fevzi Ersoy, Soner Duman, Kenan Ateş.   

Abstract

PURPOSE: The purposes of this study were to investigate the association between arm circumference and body mass index (BMI) and to discuss problems, mainly arm circumference and cuff size mismatch, that could affect the reliability of home blood pressure monitoring (HBPM) among peritoneal dialysis (PD) and hemodialysis (HD) patients.
METHODS: 525 PD and 502 HD patients from 16 centers were included in the study. A two-part questionnaire was used to gather information from the participants. Arm circumferences were categorized into four groups according to the British Hypertension Society cuff size recommendations.
RESULTS: Mean BMI and arm circumference of all participants were 25.0 kg/m(2) and 27.6 cm, respectively. There was a significant correlation between BMI and arm circumference. The mean BMI and arm circumference values were higher in PD patients than in HD patients. Requirement of a large-sized adult cuff was more common among PD patients compared to HD patients (14 % vs 8 %, p = 0.002).
CONCLUSIONS: Since HBPM is a useful tool for clinicians to improve BP control, nephrologists should be aware of the problems related to HBPM in dialysis patients and take an active role to increase the reliability of HBPM.

Entities:  

Mesh:

Year:  2012        PMID: 22752452     DOI: 10.1007/s11255-012-0219-8

Source DB:  PubMed          Journal:  Int Urol Nephrol        ISSN: 0301-1623            Impact factor:   2.370


  33 in total

Review 1.  State of the market for devices for blood pressure measurement.

Authors:  E O'Brien
Journal:  Blood Press Monit       Date:  2001-12       Impact factor: 1.444

2.  European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults.

Authors:  Eoin O'Brien; Neil Atkins; George Stergiou; Nikos Karpettas; Gianfranco Parati; Roland Asmar; Yutaka Imai; Jiguang Wang; Thomas Mengden; Andrew Shennan
Journal:  Blood Press Monit       Date:  2010-02       Impact factor: 1.444

Review 3.  Out-of-office blood pressure monitoring in chronic kidney disease.

Authors:  Rajiv Agarwal; Aldo J Peixoto; Sergio F F Santos; Carmine Zoccali
Journal:  Blood Press Monit       Date:  2009-02       Impact factor: 1.444

4.  Comparing body composition assessment tests in long-term hemodialysis patients.

Authors:  Rachelle Bross; Gangadarshni Chandramohan; Csaba P Kovesdy; Antigone Oreopoulos; Nazanin Noori; Sarah Golden; Deborah Benner; Joel D Kopple; Kamyar Kalantar-Zadeh
Journal:  Am J Kidney Dis       Date:  2010-03-25       Impact factor: 8.860

Review 5.  European Society of Hypertension practice guidelines for home blood pressure monitoring.

Authors:  G Parati; G S Stergiou; R Asmar; G Bilo; P de Leeuw; Y Imai; K Kario; E Lurbe; A Manolis; T Mengden; E O'Brien; T Ohkubo; P Padfield; P Palatini; T G Pickering; J Redon; M Revera; L M Ruilope; A Shennan; J A Staessen; A Tisler; B Waeber; A Zanchetti; G Mancia
Journal:  J Hum Hypertens       Date:  2010-06-03       Impact factor: 3.012

6.  Validation of the Omron M3 Intellisense (HEM-7051-E) upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010 in a stage 3-5 chronic kidney disease population.

Authors:  Tekin Akpolat; Emre Erdem; Türkan Aydogdu
Journal:  Kidney Blood Press Res       Date:  2011-09-10       Impact factor: 2.687

7.  Validation of the Lloyds pharmacy BP11 oscillometric blood pressure monitor according to the international protocol of the European society of hypertension.

Authors:  Andrew Coleman; Stephen Steel; Annemarie deGreeff; Andrew Shennan
Journal:  Blood Press Monit       Date:  2010-06       Impact factor: 1.444

8.  Use of home sphygmomanometers in Turkey: a nation-wide survey.

Authors:  Tekin Akpolat; Yunus Erdem; Ulver Derici; Sehsuvar Erturk; Sali Caglar; Enver Hasanoglu; Oktay Karatan; Sukru Sindel; Cetin Turgan
Journal:  Hypertens Res       Date:  2011-11-17       Impact factor: 3.872

9.  Determining the accuracy of blood pressure measurement by the Omron HEM-907 before and after hemodialysis.

Authors:  Marek Czarkowski; Monika Staszków; Kacper Kostyra; Zuhier Shebani; Stanisław Niemczyk; Joanna Matuszkiewicz-Rowińska
Journal:  Blood Press Monit       Date:  2009-10       Impact factor: 1.444

10.  Call to action on use and reimbursement for home blood pressure monitoring: a joint scientific statement from the American Heart Association, American Society of Hypertension, and Preventive Cardiovascular Nurses Association.

Authors:  Thomas G Pickering; Nancy Houston Miller; Gbenga Ogedegbe; Lawrence R Krakoff; Nancy T Artinian; David Goff
Journal:  J Cardiovasc Nurs       Date:  2008 Jul-Aug       Impact factor: 2.083

View more
  1 in total

1.  The Effect of Cuff Size on Blood Pressure Measurement in Obese Surgical Patients: A Prospective Crossover Clinical Trial.

Authors:  Serpil Yüksel; Gülay Altun-Uğraş; Nurhan Altınok; Necla Demir
Journal:  Florence Nightingale J Nurs       Date:  2020-07-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.