Literature DB >> 22708979

Risks and benefits of invasive epilepsy surgery workup with implanted subdural and depth electrodes.

Jörg Wellmer1, Ferdinand von der Groeben, Ute Klarmann, Christian Weber, Christian E Elger, Horst Urbach, Hans Clusmann, Marec von Lehe.   

Abstract

PURPOSE: In patients with pharmacoresistant focal-onset seizures, invasive presurgical workup can identify epilepsy surgery options when noninvasive workup has failed. Yet, the potential benefit must be balanced with procedure-related risks. This study examines risks associated with the implantation of subdural strip and grid, and intracerebral depth electrodes. Benefit of invasive monitoring is measured by seizure outcomes. Diagnostic procedures made possible by electrode implantation are described.
METHODS: Retrospective evaluation of invasive workups in 242 epilepsy surgery candidates and additional 18 patients with primary brain tumors implanted for mapping only. Complications are scaled in five grades of severity. A regression analysis identifies risk factors for complications. Outcome is classified according to Engel's classification. KEY
FINDINGS: Complications of any type were documented in 23% of patients, and complications requiring surgical revision in 9%. We did not find permanent morbidity or mortality. Major risk factor for complications was the implantation of grids and the implantation of electrode assemblies comprising strip and grid electrodes. Depth electrodes were significantly correlated with a lower risk. Tumors were not correlated with higher complication rates. Chronic invasive monitoring of 3-40 days allowed seizure detection in 99.2% of patients with epilepsy and additional extensive mapping procedures. Patients with epilepsy with follow-up >24 months (n = 165) had an Engel class 1a outcome in 49.7% if epilepsy surgery was performed, but only 6.3% when surgery was rejected. SIGNIFICANCE: The benefit of chronic invasive workup outweighs its risks, but complexity of implantations should be kept to a minimum. Wiley Periodicals, Inc.
© 2012 International League Against Epilepsy.

Entities:  

Mesh:

Year:  2012        PMID: 22708979     DOI: 10.1111/j.1528-1167.2012.03545.x

Source DB:  PubMed          Journal:  Epilepsia        ISSN: 0013-9580            Impact factor:   5.864


  35 in total

1.  Surgery for epilepsy.

Authors:  Siobhan West; Sarah J Nevitt; Jennifer Cotton; Sacha Gandhi; Jennifer Weston; Ajay Sudan; Roberto Ramirez; Richard Newton
Journal:  Cochrane Database Syst Rev       Date:  2019-06-25

2.  Integrating artificial intelligence with real-time intracranial EEG monitoring to automate interictal identification of seizure onset zones in focal epilepsy.

Authors:  Yogatheesan Varatharajah; Brent Berry; Jan Cimbalnik; Vaclav Kremen; Jamie Van Gompel; Matt Stead; Benjamin Brinkmann; Ravishankar Iyer; Gregory Worrell
Journal:  J Neural Eng       Date:  2018-06-01       Impact factor: 5.379

3.  Hematoma-Related Nonhabitual Seizures during Subdural Electrode Monitoring.

Authors:  Kyoung Jin Hwang; Eun Yeon Joo; Seung Bong Hong; Dae Won Seo
Journal:  J Clin Neurol       Date:  2018-05-31       Impact factor: 3.077

4.  Functional MRI and direct cortical stimulation: Prediction of postoperative language decline.

Authors:  Rachel Rolinski; Alison Austermuehle; Edythe Wiggs; Shubhi Agrawal; Leigh N Sepeta; William D Gaillard; Kareem A Zaghloul; Sara K Inati; William H Theodore
Journal:  Epilepsia       Date:  2019-02-11       Impact factor: 5.864

Review 5.  The Potential for a Speech Brain-Computer Interface Using Chronic Electrocorticography.

Authors:  Qinwan Rabbani; Griffin Milsap; Nathan E Crone
Journal:  Neurotherapeutics       Date:  2019-01       Impact factor: 7.620

6.  Major and minor complications in extraoperative electrocorticography: A review of a national database.

Authors:  John D Rolston; Dario J Englot; Susannah Cornes; Edward F Chang
Journal:  Epilepsy Res       Date:  2016-02-10       Impact factor: 3.045

Review 7.  Brain Tumor-Related Epilepsy: a Current Review of the Etiologic Basis and Diagnostic and Treatment Approaches.

Authors:  Jeffrey M Politsky
Journal:  Curr Neurol Neurosci Rep       Date:  2017-09       Impact factor: 5.081

Review 8.  [Invasive stimulation procedures and EEG diagnostics in epilepsy].

Authors:  A Schulze-Bonhage; H M Hamer; M Hirsch; M Hagge
Journal:  Nervenarzt       Date:  2016-08       Impact factor: 1.214

9.  Outcome after individualized stereoelectroencephalography (sEEG) implantation and navigated resection in patients with lesional and non-lesional focal epilepsy.

Authors:  Jun Thorsteinsdottir; Christian Vollmar; Jörg-Christian Tonn; Friedrich-Wilhelm Kreth; Soheyl Noachtar; Aurelia Peraud
Journal:  J Neurol       Date:  2019-01-30       Impact factor: 4.849

10.  Decision analysis of intracranial monitoring in non-lesional epilepsy.

Authors:  G C Hotan; A F Struck; M T Bianchi; E N Eskandar; A J Cole; M B Westover
Journal:  Seizure       Date:  2016-06-18       Impact factor: 3.184

View more