Cyclic fatigue of nickel-titanium rotary instruments in a double (S-shaped) simulated curvature.

Dina Al-Sudani1, Nicola M Grande, Gianluca Plotino, Giorgio Pompa, Stefano Di Carlo, Luca Testarelli, Gianluca Gambarini.   

Abstract

INTRODUCTION: The goal of the present study was to test the fatigue resistance of nickel-titanium rotary files in a double curvature (S-shaped) artificial root canal and to compare those results with single curvature artificial root canals.
METHODS: Two nickel-titanium endodontic instruments consisting of identical instrument sizes (constant .06 taper and 0.25 tip diameter) were tested, ProFile instruments and Vortex instruments. Both instruments were tested for fatigue inside an artificial canal with a double curvature and inside a curved artificial canal with a single curvature. Ten instruments for each group were tested to fracture in continuous rotary motion at 300 rpm. Number of cycles to failure (NCF) was calculated to the nearest whole number, and the length of the fractured fragment was measured in millimeters. Data were statistically analyzed with a level of significance set at 95% confidence level.
RESULTS: The NCF value was always statistically lower in the double curved artificial canal when compared with the single curve (P < .05) in both the apical and coronal curvatures. Statistically significant differences (P < .05) were noted between instruments of the same size of different brand only in the single curve; ProFile registered a mean of 633.5 ± 75.1 NCF, whereas Vortex registered a mean of 548 ± 48.9 NCF.
CONCLUSIONS: Regardless of the differences between the instruments used in the present study, the results suggest that the more complex is the root canal, the more adverse are the effects on the cyclic fatigue resistance of the instruments.
Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22703666     DOI: 10.1016/j.joen.2012.03.025

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  25 in total

1.  Cyclic fatigue of instruments for endodontic glide path.

Authors:  Gianluca Gambarini; Gianluca Plotino; GianPaolo Sannino; Nicola Maria Grande; Alessio Giansiracusa; Lucila Piasecki; Ulisses Xavier da Silva Neto; Dina Al-Sudani; Luca Testarelli
Journal:  Odontology       Date:  2013-11-07       Impact factor: 2.634

2.  Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence.

Authors:  Gianluca Gambarini; Gianluca Plotino; Lucila Piasecki; Dina Al-Sudani; Luca Testarelli; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2015-05-18

3.  Does the type of endodontic access influence in the cyclic fatigue resistance of reciprocating instruments?

Authors:  Emmanuel João Nogueira Leal Silva; Rafael Santos Attademo; Marcia Cristina Dutra da Silva; Karem Paula Pinto; Henrique Dos Santos Antunes; Victor Talarico Leal Vieira
Journal:  Clin Oral Investig       Date:  2020-11-21       Impact factor: 3.573

4.  Mechanical resistance of carbon and stainless steel hand instruments used in a reciprocating handpiece.

Authors:  Lucila Piasecki; Dina Al-Sudani; Alessio Giansiracusa Rubini; Giampaolo Sannino; Giampaolo Sonnino; Maurizio Bossù; Luca Testarelli; Roberto Di Giorgio; Ulisses Xavier da Silva-Neto; Christian Giampietro Brandão; Gianluca Gambarini
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04

5.  The influence of three different instrumentation techniques on the incidence of postoperative pain after endodontic treatment.

Authors:  Gianluca Gambarini; Luca Testarelli; Massimo De Luca; Valerio Milana; Gianluca Plotino; Nicola Maria Grande; Alessio Giansiracusa Rubini; Dina Al Sudani; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2013-03-20

6.  Effect of canal curvature location on the cyclic fatigue resistance of reciprocating files.

Authors:  Tyler Sobotkiewicz; Xiangya Huang; Markus Haapasalo; Christophe Mobuchon; Ahmed Hieawy; Jinghao Hu; Huimin Zhou; Zhejun Wang; Ya Shen
Journal:  Clin Oral Investig       Date:  2020-06-02       Impact factor: 3.573

7.  A comparative study of mechanical resistance of two reciprocating files.

Authors:  Dario Di Nardo; Massimo Galli; Antonio Morese; Marco Seracchiani; Valerio Ferri; Gabriele Miccoli; Gianluca Gambarini; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-03-01

8.  In vitro resistance to fracture of two nickel-titanium rotary instruments made with different thermal treatments.

Authors:  Gabriele Miccoli; Gianfranco Gaimari; Marco Seracchiani; Antonio Morese; Tatyana Khrenova; Dario Di Nardo
Journal:  Ann Stomatol (Roma)       Date:  2017-11-08

9.  An in vitro cyclic fatigue resistance comparison of conventional and new generation nickel-titanium rotary files.

Authors:  Celia Ruiz-Sánchez; Vicente Faus-Matoses; Teresa Alegre-Domingo; Ignacio Faus-Matoses; Vicente-José Faus-Llácer
Journal:  J Clin Exp Dent       Date:  2018-08-01

10.  Frequency and distribution of early tooth loss and endodontic treatment needs of permanent first molars in a Turkish pediatric population.

Authors:  Sezer Demirbuga; Oznur Tuncay; Kenan Cantekin; Muhammed Cayabatmaz; Asiye Nur Dincer; Halil İbrahim Kilinc; Ahmet Ercan Sekerci
Journal:  Eur J Dent       Date:  2013-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.