Literature DB >> 22702438

Effects of rest temperature, contact activation, and sample technique on canine thrombelastography.

Alan G Ralph1, Benjamin M Brainard, Jennifer R Pittman, Danielle M Babski, Amie Koenig.   

Abstract

OBJECTIVE: To determine the effects of rest temperature, contact activation (CA), and sample collection technique on thrombelastography (TEG) using canine whole blood.
DESIGN: Prospective, experimental study.
SETTING: University-based research facility. ANIMALS: Twelve healthy, adult, mixed-breed dogs.
INTERVENTIONS: Blood was collected by jugular venipuncture. Tubes containing 3.2% sodium citrate, with and without 75 μg/mL corn trypsin inhibitor (CTI), were filled by vacuum. Samples rested for 30 minutes at 3 temperatures: 37°C, room temperature (RT, 20-22°C), or warmed to 37°C 5 minutes prior to analysis (prewarmed). Samples were analyzed at 37°C. CTI-treated samples were analyzed with and without 1:50,000 tissue factor (TF) as activator. Six dogs were also tested similarly using a needle/syringe collection technique. MEASUREMENT AND MAIN
RESULTS: Prewarmed samples exhibited greater MA compared to RT (55.5 ± 7.2 mm vs. 53.5 ± 6.0, P< 0.05), while 37°C samples exhibited a steeper angle (56.7 ± 10.4°C vs. 52.4 ± 8.6°C) and greater MA (55.9 ± 7.5 mm vs. 53.5 ± 6.0 mm) than RT samples (both P< 0.05). CTI-treated samples were hypocoagulable (R time 45 min [7.5-56.8 min], angle 8.2°C [5.1-42.5°C], MA 29.2 ± 9.7 mm, P< 0.001), with TF activation returning all but the angle (42.5 ± 7.6°C) to values similar to citrated samples (angle = 56.7 ± 10.4°C, P = 0.017). Collection using a syringe/needle method revealed a shorter R time for prewarmed samples only (R time 4.7 ± 0.7 min, vs. 5.6 ± 0.8 min for vacuum-collected samples, P = 0.008).
CONCLUSIONS: Even in the absence of exogenous activators, CA has an impact on canine TEG results. The effects of rest temperatures and sample collection technique on TEG appear to be minimal. © Veterinary Emergency and Critical Care Society 2012.

Entities:  

Mesh:

Year:  2012        PMID: 22702438     DOI: 10.1111/j.1476-4431.2012.00730.x

Source DB:  PubMed          Journal:  J Vet Emerg Crit Care (San Antonio)        ISSN: 1476-4431


  7 in total

1.  The effect of analytical temperature on thromboelastography tracings in dogs.

Authors:  Marie T Keith; Nolan V Chalifoux; Yekaterina Buriko
Journal:  J Vet Diagn Invest       Date:  2021-09-13       Impact factor: 1.569

2.  Effect of rest temperature on rotational thromboelastometry in New Zealand White rabbits.

Authors:  Kelsea A Studer; Andrew Hanzlicek; Nicola Di Girolamo; William Womble; Debosree Pathak; Rachel Maranville; Ian Kanda; João Brandão
Journal:  J Vet Diagn Invest       Date:  2020-11-06       Impact factor: 1.279

3.  Evaluation of thromboelastography in two factor XII-deficient cats.

Authors:  Shauna L Blois; Marie K Holowaychuk; R Darren Wood
Journal:  JFMS Open Rep       Date:  2015-06-01

4.  Correlation between thromboelastography and traditional coagulation test parameters in hospitalized dogs.

Authors:  Jean V Rubanick; Medora B Pashmakova; Micah A Bishop; James W Barr
Journal:  Vet Med (Auckl)       Date:  2017-02-08

5.  Impact of general anesthesia on rotational thromboelastometry (ROTEM) parameters and standard plasmatic coagulation tests in healthy Beagle dogs.

Authors:  Andrea Schwarz; Louise F Martin; Francesca Del Chicca; Nadja E Sigrist; Annette Pn Kutter
Journal:  Vet Anim Sci       Date:  2021-12-04

6.  Evaluation of the Effect of Storage Time on ROTEM S® Parameters in Healthy and Ill Dogs.

Authors:  Nicole Weingand; Johanna Vuille-Dit-Bille; Rahel Jud Schefer; Annette P N Kutter; Martina Stirn; Katja-Nicole Adamik; Nadja E Sigrist
Journal:  Animals (Basel)       Date:  2022-08-07       Impact factor: 3.231

7.  Use of Citrated Whole Blood for Point-of-Care Viscoelastic Coagulation Testing in Dogs.

Authors:  Whitney York; M Ryan Smith; Chin-Chi Liu
Journal:  Front Vet Sci       Date:  2022-03-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.