Literature DB >> 22699561

Corneal thickness measurement using Orbscan, Pentacam, Galilei, and ultrasound in normal and post-femtosecond laser in situ keratomileusis eyes.

Se-Hoon Park1, Suk-Kyue Choi, Doh Lee, Eun-Jung Jun, Jin-Hyoung Kim.   

Abstract

PURPOSE: To compare corneal pachymetry assessment using slit scanning imaging (Orbscan), rotating Scheimpflug imaging (Pentacam), dual Scheimpflug system (Galilei), and ultrasound pachymetry in normal and post-femtosecond (FS) laser in situ keratomileusis (LASIK) eyes.
METHODS: Sixty eyes of 60 patients were enrolled for this study, which consisted of 30 unoperated eyes (normal corneas) and 30 eyes after FS-LASIK (post-LASIK corneas). Central corneal thickness was measured sequentially using Orbscan II, Pentacam, Galilei, and ultrasound pachymetry, and the average value of measurements obtained by the 4 different methods were compared in each group.
RESULTS: In normal corneas, corneal thickness measurements were not different by all 4 methods [P = 0.202, 1-way analysis of variance (ANOVA)]. In post-LASIK corneas, the measurement was significantly different among those achieved by 4 methods (P < 0.001, 1-way ANOVA). Orbscan measurement was thinner than those yielded by Galilei, Pentacam, or ultrasound pachymetry with average of 47.7, 38.5, and 34.4 μm, respectively (all P values < 0.001, 1-way ANOVA and the Tukey multiple comparisons test) in post-LASIK corneas. Orbscan, Pentacam, and Galilei measurements showed good agreement with ultrasound pachymetry data in both groups, except Orbscan data in post-LASIK corneas showed a statistically significant difference from ultrasound pachymetry measurements (P value = 0.001, 1-way ANOVA and the Tukey multiple comparisons test).
CONCLUSIONS: Any of central corneal thicknesses obtained by all 4 measurement modalities might be acceptable before refractive surgery. However, in post-FS-LASIK eyes, measurements using Orbscan were thinner than those obtained with other modalities; in contrast, those with Pentacam or Galilei were comparable with ultrasound pachymetry.

Entities:  

Mesh:

Year:  2012        PMID: 22699561     DOI: 10.1097/ICO.0b013e31823d03fc

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  9 in total

1.  Meta-analysis of Pentacam vs. ultrasound pachymetry in central corneal thickness measurement in normal, post-LASIK or PRK, and keratoconic or keratoconus-suspect eyes.

Authors:  Wenjing Wu; Yan Wang; Lulu Xu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-11-12       Impact factor: 3.117

2.  Difference in normal corneal thickness and curvature between Mongolian and Han nationalities.

Authors:  Hai-Xia Zhao; Li Zhang; Wen-Ying Guan
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

3.  Comparison of central corneal thickness measurements with three new optical devices and a standard ultrasonic pachymeter.

Authors:  Hasan Ali Bayhan; Seray Aslan Bayhan; Izzet Can
Journal:  Int J Ophthalmol       Date:  2014-04-18       Impact factor: 1.779

4.  Comparison between Pentacam HR and Orbscan II after Hyperopic Photorefractive Keratectomy.

Authors:  Mahmoud Jabbarvand; Farshad Askarizadeh; Mohamad Reza Sedaghat; Hadi Ghadimi; Bahram Khosravi; Mohammad Aghazadeh Amiri; Foroozan Narooie-Noori
Journal:  J Ophthalmic Vis Res       Date:  2017 Oct-Dec

5.  The distribution of orbscan indices in young population.

Authors:  Hassan Hashemi; Mehdi Khabazkhoob; Negareh Yazdani; Hadi Ostadimoghaddam; Payam Nabovati; Raheleh Moravej; AbbasAli Yekta
Journal:  J Curr Ophthalmol       Date:  2016-08-31

Review 6.  Galilei Corneal Tomography for Screening of Refractive Surgery Candidates: A Review of the Literature, Part II.

Authors:  Majid Moshirfar; Mahsaw N Motlagh; Michael S Murri; Hamed Momeni-Moghaddam; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2019

7.  Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography.

Authors:  Hassan Hashemi; Zahra Heidari; Mehrdad Mohammadpour; Hamed Momeni-Moghaddam; Mehdi Khabazkhoob
Journal:  J Curr Ophthalmol       Date:  2022-07-26

8.  Longitudinal Evaluation of Cornea With Swept-Source Optical Coherence Tomography and Scheimpflug Imaging Before and After Lasik.

Authors:  Tommy C Y Chan; Sayantan Biswas; Marco Yu; Vishal Jhanji
Journal:  Medicine (Baltimore)       Date:  2015-07       Impact factor: 1.889

9.  Comparison of anterior segment changes after femtosecond laser LASIK and SMILE using a dual rotating Scheimpflug analyzer.

Authors:  Bu Ki Kim; Su Joung Mun; Young Hoon Yang; Ji Sun Kim; Jun Hyung Moon; Young Taek Chung
Journal:  BMC Ophthalmol       Date:  2019-12-11       Impact factor: 2.209

  9 in total