| Literature DB >> 22691418 |
Hyung Min Kim1, Byung Hak So, Won Jung Jeong, Se Min Choi, Kyu Nam Park.
Abstract
BACKGROUND: This study was designed to compare the effectiveness of using auscultation, pH measurements of gastric aspirates, and ultrasonography as physical examination methods to verify nasogastric tube(NGT) placement in emergency room patients with low consciousness who require NGT insertion.Entities:
Mesh:
Year: 2012 PMID: 22691418 PMCID: PMC3477076 DOI: 10.1186/1757-7241-20-38
Source DB: PubMed Journal: Scand J Trauma Resusc Emerg Med ISSN: 1757-7241 Impact factor: 2.953
Figure 1 Normal esophagus (A). White arrow indicates the nasogastric tube in the esophagus (B).
Figure 2 Sonographic visualization of a nasogastric tube. The weighted tip appears as a hyperechogenic line with a posterior acoustic shadow.
Figure 3 A mixture of 40 ml normal saline with 10 ml air was injected into the tube to visualize the hyperechogenic "fog" existing at the tip of the tube (white arrows).
Characteristics of patients
| Age (years) | 57.6 ± 17.2* |
| Gender (male/female) | 28(59.6)/19(40.4)† |
| Nasogastric tube indications | |
| Poisoning | 12(25.5) |
| Ileus | 2(4.3) |
| Intubation | 27(57.4) |
| Gastrointestinal bleeding | 6(12.8) |
| GCS** | |
| ≤8 | 33(70.2) |
| 9-14 | 14(29.8) |
*Mean ± SD, SD: standard deviation.
†Number (%).
**Glasgow coma scale.
Comparison of predictive validity
| Ultrasound (+) | 38 | 1 | 86.4 | 66.7 | 97.4 | 25.0 |
| (−) | 6 | 2 | ||||
| Auscultation (+) | 44 | 2 | 100.0 | 33.3 | 95.7 | 100.0 |
| (−) | 0 | 1 | | | | |
| pH (+) | 31 | 1 | 91.2 | 66.7 | 96.9 | 40 |
| measuring* (−) | 3 | 2 | ||||
PPV: positive predictive value.
NPV: negative predictive value.
* pH measuring: The contents were not aspirated in 10 patients.
Number of correct classification and results of Cohen Kappa analysis
| Radiology | 44*(93.6) | 3 (6.4) | | |
| Ultrasound | 39 (83.0) | 8 (17.0) | 0.299 | 0.018 |
| Auscultation | 46 (97.9) | 1 (2.1) | 0.484 | <0.001 |
| pH measuring† | 32 (86.5) | 5 (13.5) | 0.444 | 0.005 |
*Number (%).
† pH measuring: The contents were not aspirated in 10 patients.
The results of ultrasonography
| Neck | 39*(83.0) | |
| Gastric-esophageal | | |
| junction | 8 (17.0) | |
| Stomach | 6 (12.8) | 33 (70.2) |
*Number (%).