Literature DB >> 7665817

Hold that x-ray: aspirate pH and auscultation prove enteral tube placement.

M J Neumann1, C T Meyer, J L Dutton, R Smith.   

Abstract

We report here a prospective study evaluating an alternative to the roentgenographic confirmation of "fine-bore" nasoenteral feeding tubes. Of 78 nasoenteral intubations in 46 patients using a Dobbhoff (Biosearch Medical Products) weighted enteral feeding tube, gastric aspirates were evaluated in 28. Auscultation was performed in all 78. Data was collected at initial placement prior to x-ray confirmation. Observers used color-coded pH paper to analyze gastric aspirate (pH < or = 4) and/or auscultation of the epigastrium to determine feeding tube position prior to x-rays. Auscultation alone was ineffective as a confirmatory test with only 6.3% specificity (p = 0.31). Aspiration to ascertain tube position was very accurate when pH < or = 4.0 (p = 0.0005) and when it was performed. A pH value of > 4 was not very helpful in predicting malposition (37%) especially when pH altering medications were used. Aspiration of contents was successful in 85% of patients. We conclude that when the pH of the nasogastric tube aspirate is < 4.0, x-ray films are not needed to prove the accuracy of tube placement. In other situations, a film is indicated since auscultation is inaccurate.

Entities:  

Mesh:

Year:  1995        PMID: 7665817

Source DB:  PubMed          Journal:  J Clin Gastroenterol        ISSN: 0192-0790            Impact factor:   3.062


  7 in total

1.  Gastric tube placement in young children.

Authors:  Marsha L Cirgin Ellett; Joseph M B Croffie; Mervyn D Cohen; Susan M Perkins
Journal:  Clin Nurs Res       Date:  2005-08       Impact factor: 2.075

Review 2.  Naso-enteric Tube Placement: A Review of Methods to Confirm Tip Location, Global Applicability and Requirements.

Authors:  S A Milsom; J A Sweeting; H Sheahan; E Haemmerle; J A Windsor
Journal:  World J Surg       Date:  2015-09       Impact factor: 3.352

3.  The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center.

Authors:  Hyung Min Kim; Byung Hak So; Won Jung Jeong; Se Min Choi; Kyu Nam Park
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2012-06-12       Impact factor: 2.953

Review 4.  Nasogastric Tube Feeding in Older Patients: A Review of Current Practice and Challenges Faced.

Authors:  Devkishan Chauhan; Surabhi Varma; Melanie Dani; Michael B Fertleman; Louis J Koizia
Journal:  Curr Gerontol Geriatr Res       Date:  2021-01-21

5.  Validation of the RightSpot™ device for determination of gastric pH during nasogastric tube placement.

Authors:  Charles R Lambert; David Varlotta; Marjorie Posey; Jadie L Heberlein; Janice M Shirley
Journal:  Int J Emerg Med       Date:  2013-07-17

6.  Potential risk of malposition of nasogastric tube using nose-ear-xiphoid measurement.

Authors:  Yen-Chun Chen; Lien-Yen Wang; Yu-Jun Chang; Chao-Pin Yang; Tsung-Ju Wu; Fung-Ru Lin; Sen-Yung Liu; Ta-Sen Wei
Journal:  PLoS One       Date:  2014-02-10       Impact factor: 3.240

7.  Selecting pH cut-offs for the safe verification of nasogastric feeding tube placement: a decision analytical modelling approach.

Authors:  Melody Zhifang Ni; Jeremy R Huddy; Oliver H Priest; Sisse Olsen; Lawrence D Phillips; Patrick M M Bossuyt; George B Hanna
Journal:  BMJ Open       Date:  2017-11-04       Impact factor: 2.692

  7 in total