Literature DB >> 12539253

Sonographic detection of a malpositioned feeding tube causing esophageal perforation in a neonate.

Kenichi Maruyama1, Takeshi Shiojima, Takenobu Koizumi.   

Abstract

We report a case of esophageal perforation caused by a malpositioned feeding tube in a neonate of extremely low birth weight, 632 g. The infant had respiratory distress, which increased rapidly when he was 6 days old. Radiography revealed right-sided hydrothorax that had not been evident a day earlier but no sign of a perforated esophagus. We performed sonography, which revealed fluid in the right pleural cavity and extra-esophageal placement of the feeding tube. Analysis of a fluid specimen obtained on thoracocentesis indicated that the fluid was feeding formula. The feeding tube's misplacement was confirmed sonographically by injecting a small amount of sterile distilled water into the tube and visualizing its entry into the pleural cavity. The feeding tube was removed, and antimicrobial agents were administered. When the infant was 15 days old, feeding resumed through another tube, the placement of which was verified radiographically. The infant was discharged when he was 118 days old with no severe complications, although he had mild chronic lung disease. Because radiography did not reveal the tube's misplacement in this case, we believe that the use of sonography can contribute to an early diagnosis of esophageal perforation in such cases. Copyright 2003 Wiley Periodicals, Inc. J Clin Ultrasound 31:108-110, 2003

Entities:  

Mesh:

Year:  2003        PMID: 12539253     DOI: 10.1002/jcu.10133

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  5 in total

1.  Sonography as an alternative to radiography for nasogastric feeding tube location.

Authors:  Cécile Vigneau; Jean-Luc Baudel; Bertrand Guidet; Georges Offenstadt; Eric Maury
Journal:  Intensive Care Med       Date:  2005-09-20       Impact factor: 17.440

2.  4-Point ultrasonography to confirm the correct position of the nasogastric tube in 114 critically ill patients.

Authors:  Marianna Zatelli; Norberto Vezzali
Journal:  J Ultrasound       Date:  2016-10-28

3.  The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center.

Authors:  Hyung Min Kim; Byung Hak So; Won Jung Jeong; Se Min Choi; Kyu Nam Park
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2012-06-12       Impact factor: 2.953

4.  Bedside ultrasonography for the confirmation of gastric tube placement in the neonate.

Authors:  Yunus Oktay Atalay; Ahmet Veysel Polat; Elif Ozyazici Ozkan; Leman Tomak; Canan Aygun; Joseph Drew Tobias
Journal:  Saudi J Anaesth       Date:  2019 Jan-Mar

5.  Bedside Ultrasonography in Evaluating Mediastinum Leakage in an Extremely-Low-Birth-Weight Infant with Esophageal Perforation.

Authors:  Mitsuhiro Haga; Yumiko Sato; Tomo Kakihara; Wakako Sumiya; Masayuki Kanno; Tetsuya Ishimaru; Masaki Shimizu; Hiroshi Kawashima
Journal:  AJP Rep       Date:  2022-02-04
  5 in total