B Kelly Han1, Katharine L R Grant, Ross Garberich, Martin Sedlmair, Jana Lindberg, John R Lesser.   

Abstract

BACKGROUND: Pediatric cardiac patients often undergo repeat diagnostic testing, resulting in relatively high cumulative medical radiation exposure. Low-dose CT scanning techniques used to decrease radiation exposure may result in reduced image quality.
OBJECTIVE: This study evaluates a prototype iterative reconstruction algorithm, sinogram-affirmed iterative reconstruction (SAFIRE), to determine the effect on qualitative and quantitative measures of image quality in pediatric cardiac CT datasets, compared with a standard weighted filtered back projection (wFBP) algorithm.
METHODS: Seventy-four datasets obtained on a 128-slice dual-source CT system were evaluated for image quality using both the wFBP and the prototype iterative reconstruction algorithm. Contrast, noise, contrast-to-noise ratio, signal-to-noise ratio, and qualitative image quality were compared between groups. Data were analyzed as medians and 25th and 75th percentiles, and groups were compared with the use of the Wilcoxon singed-rank test or k sample equality of medians test.
RESULTS: There was a 34% decrease in noise, a 41% increase in contrast-to-noise ratio, and a 56% increase in signal-to-noise ratio in the prototype iterative reconstruction, compared with wFBP. All differences were statistically significant (P < 0.001). Qualitative measures of image noise and noise texture were also improved in the iterative reconstruction group (P < 0.001 for both). Diagnostic confidence was similar between reconstruction techniques. Median scan dose length product was 15.5 mGy · cm.
CONCLUSION: The prototype iterative reconstruction algorithm studied significantly reduces image noise and improves qualitative and quantitative measures of image quality in low-dose pediatric CT datasets, compared with standard wFBP.
Copyright © 2012 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22682262     DOI: 10.1016/j.jcct.2012.04.008

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  20 in total

1.  Evaluation of an iterative model-based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography.

Authors:  Peter B Noël; Thomas Köhler; Alexander A Fingerle; Kevin M Brown; Stanislav Zabic; Daniela Münzel; Bernhard Haller; Thomas Baum; Martin Henninger; Reinhard Meier; Ernst J Rummeny; Martin Dobritz
Journal:  J Med Imaging (Bellingham)       Date:  2014-10-09

2.  Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography.

Authors:  Lin Yang; Jian Zhuang; Meiping Huang; Changhong Liang; Hui Liu
Journal:  Pediatr Radiol       Date:  2016-09-16

3.  Half-dose abdominal CT with sinogram-affirmed iterative reconstruction technique in children - comparison with full-dose CT with filtered back projection.

Authors:  Minwook Lee; Myung-Joon Kim; Kyung Hwa Han; Mi-Jung Lee
Journal:  Pediatr Radiol       Date:  2014-07-17

4.  Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality.

Authors:  Bouchra Habib Geryes; Raphael Calmon; Diala Khraiche; Nathalie Boddaert; Damien Bonnet; Francesca Raimondi
Journal:  Eur Radiol       Date:  2015-10-03       Impact factor: 5.315

Review 5.  The role of advanced reconstruction algorithms in cardiac CT.

Authors:  Sandra S Halliburton; Yuki Tanabe; Sasan Partovi; Prabhakar Rajiah
Journal:  Cardiovasc Diagn Ther       Date:  2017-10

Review 6.  Radiation dose management for pediatric cardiac computed tomography: a report from the Image Gently 'Have-A-Heart' campaign.

Authors:  Cynthia K Rigsby; Sarah E McKenney; Kevin D Hill; Anjali Chelliah; Andrew J Einstein; B Kelly Han; Joshua D Robinson; Christina L Sammet; Timothy C Slesnick; Donald P Frush
Journal:  Pediatr Radiol       Date:  2018-01-01

7.  Estimating detectability index in vivo: development and validation of an automated methodology.

Authors:  Taylor Brunton Smith; Justin Solomon; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2017-12-11

8.  Effect of Radiation Dose Reduction and Reconstruction Algorithm on Image Noise, Contrast, Resolution, and Detectability of Subtle Hypoattenuating Liver Lesions at Multidetector CT: Filtered Back Projection versus a Commercial Model-based Iterative Reconstruction Algorithm.

Authors:  Justin Solomon; Daniele Marin; Kingshuk Roy Choudhury; Bhavik Patel; Ehsan Samei
Journal:  Radiology       Date:  2017-02-07       Impact factor: 11.105

9.  High pitch, low voltage dual source CT pulmonary angiography: assessment of image quality and diagnostic acceptability with hybrid iterative reconstruction.

Authors:  Patrick D McLaughlin; T Liang; M Homiedan; L J Louis; T W O'Connell; Karl Krzymyk; S Nicolaou; J R Mayo
Journal:  Emerg Radiol       Date:  2014-07-04

10.  Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease.

Authors:  Akihiro Tada; Shuhei Sato; Yuichiro Kanie; Takashi Tanaka; Ryota Inai; Noriaki Akagi; Yusuke Morimitsu; Susumu Kanazawa
Journal:  Pediatr Cardiol       Date:  2015-11-12       Impact factor: 1.655

View more