Literature DB >> 26563276

Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease.

Akihiro Tada1, Shuhei Sato2, Yuichiro Kanie2, Takashi Tanaka2, Ryota Inai2, Noriaki Akagi2, Yusuke Morimitsu2, Susumu Kanazawa2.   

Abstract

The objective of this study was to assess factors affecting image quality of 320-row computed tomography angiography (CTA) of coronary arteries in children with congenital heart disease (CHD). We retrospectively reviewed 28 children up to 3 years of age with CHD who underwent prospective electrocardiography (ECG)-gated 320-row CTA with iterative reconstruction. We assessed image quality of proximal coronary artery segments using a five-point scale. Age, body weight, average heart rate, and heart rate variability were recorded and compared between two groups: patients with good diagnostic image quality in all four coronary artery segments and patients with at least one coronary artery segment with nondiagnostic image quality. Altogether, 96 of 112 segments (85.7 %) had diagnostic-quality images. Patients with nondiagnostic segments were significantly younger (10.0 ± 11.6 months) and had lower body weight (5.9 ± 2.9 kg) (each p < 0.05) than patients with diagnostic image quality of all four segments (20.6 ± 13.8 months and 8.4 ± 2.5 kg, respectively; each p < 0.05). Differences in heart rate and heart rate variability between the two imaging groups were not significant. Receiver operating characteristic analyses for predicting patients with nondiagnostic image quality revealed an optimal body weight cutoff of ≤5.6 kg and an optimal age cutoff of ≤12.5 months. Prospective ECG-gated 320-row CTA with iterative reconstruction provided feasible image quality of coronary arteries in children with CHD. Younger age and lower body weight were factors that led to poorer image quality of coronary arteries.

Entities:  

Keywords:  320-row CT; Congenital heart disease; Coronary CT angiography; ECG gated; Prospective

Mesh:

Year:  2015        PMID: 26563276     DOI: 10.1007/s00246-015-1305-3

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  24 in total

Review 1.  Paediatric cardiac computed tomography: a review of imaging techniques and radiation dose consideration.

Authors:  Carolyn Young; Andrew M Taylor; Catherine M Owens
Journal:  Eur Radiol       Date:  2010-12-28       Impact factor: 5.315

2.  Congenital anomalies of coronary arteries in complex congenital heart disease: diagnosis and analysis with dual-source CT.

Authors:  Fang-fang Yu; Bin Lu; Yang Gao; Zhi-hui Hou; U Joseph Schoepf; James V Spearman; Hui-li Cao; Ming-li Sun; Shi-liang Jiang
Journal:  J Cardiovasc Comput Tomogr       Date:  2013-11-08

3.  Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation.

Authors:  Christopher Herzog; Denise M Mulvihill; Shaun A Nguyen; Giancarlo Savino; Bernhard Schmidt; Philip Costello; Thomas J Vogl; U Joseph Schoepf
Journal:  AJR Am J Roentgenol       Date:  2008-05       Impact factor: 3.959

4.  Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method.

Authors:  Karen E Thomas; Bo Wang
Journal:  Pediatr Radiol       Date:  2008-04-08

5.  Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality.

Authors:  Tony DeFrance; Eric Dubois; Dan Gebow; Alex Ramirez; Florian Wolf; Gudrun M Feuchtner
Journal:  Int J Cardiovasc Imaging       Date:  2009-11-07       Impact factor: 2.357

6.  CT angiography of neonates and infants: comparison of radiation dose and image quality of target mode prospectively ECG-gated 320-MDCT and ungated helical 64-MDCT.

Authors:  Siddharth P Jadhav; Farahnaz Golriz; Lamya A Atweh; Wei Zhang; Rajesh Krishnamurthy
Journal:  AJR Am J Roentgenol       Date:  2015-02       Impact factor: 3.959

7.  320-detector row CT coronary angiography: effects of heart rate and heart rate variability on image quality, diagnostic accuracy and radiation exposure.

Authors:  G Sun; M Li; X-S Jiang; L Li; Z-H Peng; G-Y Li; L Xu
Journal:  Br J Radiol       Date:  2012-02-28       Impact factor: 3.039

8.  Prospective electrocardiography-triggered CT angiography of the great thoracic vessels in infants and toddlers with congenital heart disease: feasibility and image quality.

Authors:  Gregor Pache; Jochen Grohmann; Stefan Bulla; Raoul Arnold; Brigitte Stiller; Christian Schlensak; Mathias Langer; Philipp Blanke
Journal:  Eur J Radiol       Date:  2011-02-09       Impact factor: 3.528

9.  Complications associated with pediatric cardiac catheterization.

Authors:  R Vitiello; B W McCrindle; D Nykanen; R M Freedom; L N Benson
Journal:  J Am Coll Cardiol       Date:  1998-11       Impact factor: 24.094

10.  Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings.

Authors:  Hyun Woo Goo; Dong-Man Seo; Tae-Jin Yun; Jeong-Jun Park; In-Sook Park; Jae Kon Ko; Young Hwee Kim
Journal:  Pediatr Radiol       Date:  2009-01-22
View more
  3 in total

1.  Evaluation of coronary artery variations using dual-source coronary computed tomography angiography in neonates with transposition of the great arteries.

Authors:  Yuko Odawara; Nobuko Kawamura; Yuzo Yamasaki; Joji Hashimoto; Shiro Ishikawa; Hiroshi Honda
Journal:  Jpn J Radiol       Date:  2019-01-02       Impact factor: 2.374

2.  Image Quality of Coronary Arteries on Non-electrocardiography-gated High-Pitch Dual-Source Computed Tomography in Children with Congenital Heart Disease.

Authors:  Yuichiro Kanie; Shuhei Sato; Akihiro Tada; Susumu Kanazawa
Journal:  Pediatr Cardiol       Date:  2017-07-08       Impact factor: 1.655

3.  Pediatric 320-row cardiac computed tomography using electrocardiogram-gated model-based full iterative reconstruction.

Authors:  Go Shirota; Eriko Maeda; Yoko Namiki; Razibul Bari; Kenji Ino; Rumiko Torigoe; Osamu Abe
Journal:  Pediatr Radiol       Date:  2017-06-30
  3 in total