Literature DB >> 2266792

Wireless retrospective gating: application to cine cardiac imaging.

T A Spraggins1.   

Abstract

A new "wireless" method of cardiac imaging is introduced, which, unlike ECG triggering, allows imaging the heart at end-diastole, and greatly reduces smearing artifacts in the phase-encoding direction. It is an improvement over ECG-driven retrospective gating, in that patients with poor ECGs can be imaged. This method extends the applicability of cardiac imaging, and since it requires no physiological monitoring hardware, can be implemented easily on any MR imager. The images produced by this method are superior to those from ECG triggering, especially when viewed in a "cine" loop. The technique described herein is, furthermore, extendable to any area where periodic or quasi-periodic motion is a problem.

Entities:  

Mesh:

Year:  1990        PMID: 2266792     DOI: 10.1016/0730-725x(90)90001-i

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  18 in total

1.  Prospective self-gating for swallowing motion: a feasibility study in carotid artery wall MRI using three-dimensional variable-flip-angle turbo spin-echo.

Authors:  Zhaoyang Fan; Sven Zuehlsdorff; Xin Liu; Debiao Li
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

2.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  Self-gated PROPELLER-encoded cine cardiac imaging.

Authors:  Chi-Chung Wang; Teng-Yi Huang
Journal:  Int J Cardiovasc Imaging       Date:  2011-11-01       Impact factor: 2.357

4.  Self-gating MR imaging of the fetal heart: comparison with real cardiac triggering.

Authors:  Jin Yamamura; Michael Frisch; Hannes Ecker; Joachim Graessner; Kurt Hecher; Gerhard Adam; Ulrike Wedegärtner
Journal:  Eur Radiol       Date:  2010-07-30       Impact factor: 5.315

5.  [Idiopathic normal-pressure hydrocephalus. Flow measurement of cerebrospinal fluid using phase contrast MRI and its diagnostics importance].

Authors:  F T Al-Zain; G Rademacher; J Lemcke; J Mutze; U Meier
Journal:  Nervenarzt       Date:  2007-02       Impact factor: 1.214

6.  Prospective cardiac motion self-gating.

Authors:  Fei Han; Stanislas Rapacchi; Peng Hu
Journal:  Quant Imaging Med Surg       Date:  2017-04

7.  Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition.

Authors:  Jing Liu; Pascal Spincemaille; Noel C F Codella; Thanh D Nguyen; Martin R Prince; Yi Wang
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

8.  Longitudinal free-breathing MRI measurement of murine lung physiology in a progressive model of lung fibrosis.

Authors:  Jinbang Guo; William D Hardie; Zackary I Cleveland; Cynthia Davidson; Xuefeng Xu; Satish K Madala; Jason C Woods
Journal:  J Appl Physiol (1985)       Date:  2019-02-07

9.  Self-gated MRI of multiple beat morphologies in the presence of arrhythmias.

Authors:  Francisco Contijoch; Srikant Kamesh Iyer; James J Pilla; Paul Yushkevich; Joseph H Gorman; Robert C Gorman; Harold Litt; Yuchi Han; Walter R T Witschey
Journal:  Magn Reson Med       Date:  2016-08-31       Impact factor: 4.668

10.  Self-gated fat-suppressed cardiac cine MRI.

Authors:  R Reeve Ingle; Juan M Santos; William R Overall; Michael V McConnell; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2014-05-07       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.