Literature DB >> 22624893

Visual simulation through different intraocular lenses using adaptive optics: effect of tilt and decentration.

David Madrid-Costa1, Javier Ruiz-Alcocer, Cari Pérez-Vives, Teresa Ferrer-Blasco, Norberto López-Gil, Robert Montés-Micó.   

Abstract

PURPOSE: To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality.
SETTING: University of Valencia, Valencia, Spain.
DESIGN: Cohort study.
METHODS: The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured.
RESULTS: Ten eyes of 10 patients were evaluated. When the IOLs were centered, there were no differences in visual acuity between the 4 IOLs at any contrast. The aberration-correcting IOLs were more sensitive to tilt and decentration than the spherical IOLs; Tecnis ZA9003 IOL was the most sensitive to decentration and the Acrysof IQ SN60WF IOL was the most sensitive to tilt. Higher residual spherical aberration slightly improved depth of focus and the tolerance to defocus.
CONCLUSIONS: The results in this study suggest that the aspheric aberration-correcting and spherical IOLs provided comparable visual quality when centered in eyes in which the corneal higher-order aberrations are those of the average of the human cornea. Tilt and decentration of the IOLs had an impact on visual quality, with aberration-correcting IOLs having a greater effect than the spherical IOLs.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22624893     DOI: 10.1016/j.jcrs.2012.01.029

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

1.  Measurement of angle Kappa with Orbscan II and Galilei G4: effect of accommodation.

Authors:  Alberto Domínguez-Vicent; Daniel Monsálvez-Romín; Cari Pérez-Vives; Teresa Ferrer-Blasco; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-11-20       Impact factor: 3.117

2.  Optical quality of aspheric toric intraocular lenses at different degrees of decentering.

Authors:  Cari Pérez-Vives; Teresa Ferrer-Blasco; David Madrid-Costa; Santiago García-Lázaro; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-04-22       Impact factor: 3.117

3.  [Pupil centroid shift: Marketing tool or essential clinical parameter?].

Authors:  I Fischinger; T G Seiler; G Schmidinger; T Seiler
Journal:  Ophthalmologe       Date:  2015-08       Impact factor: 1.059

4.  Effect of even and odd-order aberrations on the accommodation response.

Authors:  Aikaterini I Moulakaki; Antonio J Del Águila-Carrasco; José J Esteve-Taboada; Robert Montés-Micó
Journal:  Int J Ophthalmol       Date:  2017-06-18       Impact factor: 1.779

5.  In vitro optical performance of a new aberration-free intraocular lens.

Authors:  D Madrid-Costa; J Ruiz-Alcocer; T Ferrer-Blasco; S García-Lázaro; R Montés-Micó
Journal:  Eye (Lond)       Date:  2014-02-21       Impact factor: 3.775

6.  Predictability of pseudophakic refraction using patient-customized paraxial eye models.

Authors:  Yu-Cherng Chang; Florence Cabot; Bianca Maceo Heilman; Larissa Meza; Marco Ruggeri; Arthur Ho; Sonia H Yoo; Jean-Marie Parel; Fabrice Manns
Journal:  J Cataract Refract Surg       Date:  2022-09-01       Impact factor: 3.528

7.  Comparing the effect of two different intraocular lenses on optical aberrations in bilaterally operated eyes for cataract.

Authors:  Esra Ayhan Tuzcu; Kuddusi Erkilic; Betul Bulut; Nilufer Ilhan
Journal:  Pak J Med Sci       Date:  2013-07       Impact factor: 1.088

8.  Evaluation of Intraocular Lens Tilt and Decentration in Congenital Ectopia Lentis by the Pentacam Scheimpflug System.

Authors:  Huiwen Ye; Zhenzhen Liu; Qianzhong Cao; Zhangkai Lian; Xinyu Zhang; Danying Zheng; Guangming Jin
Journal:  J Ophthalmol       Date:  2022-03-11       Impact factor: 1.909

9.  Effects of capsular tension ring on surgical outcomes of premium intraocular lens in patients with suspected zonular weakness.

Authors:  Teruyuki Miyoshi; Shuhei Fujie; Hironori Yoshida; Hiroshi Iwamoto; Hideki Tsukamoto; Tetsuro Oshika
Journal:  PLoS One       Date:  2020-02-24       Impact factor: 3.240

10.  Decentration and tilt of plate-haptic multifocal intraocular lenses in myopic eyes.

Authors:  Jiaqi Meng; Wenwen He; Xianfang Rong; Ao Miao; Yi Lu; Xiangjia Zhu
Journal:  Eye Vis (Lond)       Date:  2020-04-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.