Literature DB >> 22622666

Magnetically guided irrigated gold-tip catheter ablation of persistent atrial fibrillation--techniques, procedural parameters and outcome.

Bogdan Muntean1, Klaus-Jürgen Gutleben, Johannes Heintze, Jürgen Vogt, Dieter Horstkotte, Georg Nölker.   

Abstract

PURPOSE: Magnetically guided irrigated ablation has been introduced for atrial fibrillation (AF) ablation. However, data on ablation of persistent AF is scarce, and first-generation platinum-iridium catheters were burdened by char formation at the catheter tip. Furthermore, energy transmission of these catheters may be suboptimal. Irrigated gold-tip catheters have been introduced to overcome these problems.
METHODS: Antral pulmonary vein (PV) isolation (PVAI) was performed using a 5-mm irrigated gold-tip magnetic catheter (power setting, 48 °C maximum, 50 W, 15 s lesion duration; flow-rate, 30 mL/min). The catheter tip was guided by a uniform magnetic field and a motor drive. Left atrial maps were created using an impedance-based left atrial reconstruction and fused with a preprocedural CT or an intraprocedural rotational angiography-based scan.
RESULTS: Fifty-seven patients (42 male, 61.9 ± 8.8 years) underwent PVAI for symptomatic, drug-refractory persistent AF. PVAI was performed successfully in all patients confirmed by entrance block. Procedure time (skin-to-skin) was 214 ± 47 min (104-354 min). Fluoroscopy time was 31 ± 21 min. Ablation time was 4,153 ± 1,350 s. No char or thrombus formation was found at the catheter tip. One pericardial tamponade was observed. Freedom from atrial tachyarrhythmias could be achieved in 57.9 % of the patients included in a follow-up of 11.6 ± 4.2 month. There was a trend to a better outcome in patients without previous attempts of AF ablation (n = 48; 60.4 % vs. 44.4 %, p = 0.47).
CONCLUSIONS: Remote magnetic navigation for PVAI seems to be safe and feasible using an irrigated gold-tip catheter. Effectiveness of this novel technique can be confirmed by mid-term outcome.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22622666     DOI: 10.1007/s10840-012-9689-y

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  19 in total

1.  Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation.

Authors:  Riccardo Cappato; Hugh Calkins; Shih-Ann Chen; Wyn Davies; Yoshito Iesaka; Jonathan Kalman; You-Ho Kim; George Klein; Douglas Packer; Allan Skanes
Journal:  Circulation       Date:  2005-02-21       Impact factor: 29.690

2.  Remote-controlled magnetic pulmonary vein isolation using a new irrigated-tip catheter in patients with atrial fibrillation.

Authors:  K R Julian Chun; Erik Wissner; Buelent Koektuerk; Melanie Konstantinidou; Boris Schmidt; Thomas Zerm; Andreas Metzner; Roland Tilz; Sigrid Boczor; Alexander Fuernkranz; Feifan Ouyang; Karl-Heinz Kuck
Journal:  Circ Arrhythm Electrophysiol       Date:  2010-07-07

3.  Catheter ablation of atrial fibrillation using remote magnetic catheter navigation: a case-control study.

Authors:  Arash Arya; Ruzbeh Zaker-Shahrak; Phillip Sommer; Andreas Bollmann; Ulrike Wetzel; Thomas Gaspar; Sergio Richter; Daniela Husser; Christopher Piorkowski; Gerhard Hindricks
Journal:  Europace       Date:  2010-10-06       Impact factor: 5.214

4.  Remote magnetic navigation: human experience in pulmonary vein ablation.

Authors:  Luigi Di Biase; Tamer S Fahmy; Dimpi Patel; Rong Bai; Kenneth Civello; Oussama M Wazni; Mohamed Kanj; Claude S Elayi; Chi Keong Ching; Mohamed Khan; Lucie Popova; Robert A Schweikert; Jennifer E Cummings; J David Burkhardt; David O Martin; Mandeep Bhargava; Thomas Dresing; Walid Saliba; Mauricio Arruda; Andrea Natale
Journal:  J Am Coll Cardiol       Date:  2007-08-13       Impact factor: 24.094

5.  Robotic magnetic navigation for atrial fibrillation ablation.

Authors:  Carlo Pappone; Gabriele Vicedomini; Francesco Manguso; Filippo Gugliotta; Patrizio Mazzone; Simone Gulletta; Nicoleta Sora; Simone Sala; Alessandra Marzi; Giuseppe Augello; Laura Livolsi; Andreina Santagostino; Vincenzo Santinelli
Journal:  J Am Coll Cardiol       Date:  2006-03-15       Impact factor: 24.094

6.  Randomized comparison between open irrigation technology and intracardiac-echo-guided energy delivery for pulmonary vein antrum isolation: procedural parameters, outcomes, and the effect on esophageal injury.

Authors:  Nassir F Marrouche; Jens Guenther; Nathan M Segerson; Marcos Daccarett; Harald Rittger; Harald Marschang; Volker Schibgilla; Martin Schmidt; Guido Ritscher; Georg Noelker; Johannes Brachmann
Journal:  J Cardiovasc Electrophysiol       Date:  2007-05-09

7.  Ablation for longstanding permanent atrial fibrillation: results from a randomized study comparing three different strategies.

Authors:  Claude S Elayi; Atul Verma; Luigi Di Biase; Chi Keong Ching; Dimpi Patel; Conor Barrett; David Martin; Bai Rong; Tamer S Fahmy; Yaariv Khaykin; Richard Hongo; Steven Hao; Gemma Pelargonio; Antonio Dello Russo; Michela Casella; Pietro Santarelli; Domenico Potenza; Raffaele Fanelli; Raimondo Massaro; Mauricio Arruda; Robert A Schweikert; Andrea Natale
Journal:  Heart Rhythm       Date:  2008-09-17       Impact factor: 6.343

8.  Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study.

Authors:  Thomas Neumann; Jürgen Vogt; Burghard Schumacher; Anja Dorszewski; Malte Kuniss; Hans Neuser; Klaus Kurzidim; Alexander Berkowitsch; Marcus Koller; Johannes Heintze; Ursula Scholz; Ulrike Wetzel; Michael A E Schneider; Dieter Horstkotte; Christian W Hamm; Heinz-Friedrich Pitschner
Journal:  J Am Coll Cardiol       Date:  2008-07-22       Impact factor: 24.094

9.  Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation.

Authors:  Sabine Ernst; Feifan Ouyang; Christian Linder; Klaus Hertting; Fabian Stahl; Julian Chun; Hitoshi Hachiya; Dietmar Bänsch; Matthias Antz; Karl-Heinz Kuck
Journal:  Circulation       Date:  2004-03-15       Impact factor: 29.690

10.  A randomized assessment of the incremental role of ablation of complex fractionated atrial electrograms after antral pulmonary vein isolation for long-lasting persistent atrial fibrillation.

Authors:  Hakan Oral; Aman Chugh; Kentaro Yoshida; Jean F Sarrazin; Michael Kuhne; Thomas Crawford; Nagib Chalfoun; Darryl Wells; Warangkna Boonyapisit; Srikar Veerareddy; Sreedhar Billakanty; Wai S Wong; Eric Good; Krit Jongnarangsin; Frank Pelosi; Frank Bogun; Fred Morady
Journal:  J Am Coll Cardiol       Date:  2009-03-03       Impact factor: 24.094

View more
  3 in total

Review 1.  Differences In Tissue Injury and Ablation Outcomes In Atrial Fibrillation Patients - Manual versus Robotic Catheters.

Authors:  Georg Nölker; Dieter Horstkotte; Klaus Jürgen Gutleben
Journal:  J Atr Fibrillation       Date:  2013-08-31

2.  Are the virtual lines created with the EnSite electroanatomical mapping system really continuous?

Authors:  Thais Nascimento; Fernanda Mota; Luis Felipe Neves dos Santos; Sérgio de Araújo; Mieko Okada; Marcello Franco; Angelo A V de Paola; Guilherme Fenelon
Journal:  Arq Bras Cardiol       Date:  2013-06-14       Impact factor: 2.000

3.  Comparison of the Mid-Term Outcomes of Robotic Magnetic Navigation-Guided Radiofrequency Ablation versus Cryoballoon Ablation for Persistent Atrial Fibrillation.

Authors:  Xiang Li; Yangyang Bao; Kangni Jia; Ning Zhang; Changjian Lin; Yue Wei; Yun Xie; Qingzhi Luo; Tianyou Ling; Kang Chen; Wenqi Pan; Liqun Wu; Qi Jin
Journal:  J Cardiovasc Dev Dis       Date:  2022-03-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.