Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation.

Sabine Ernst1, Feifan Ouyang, Christian Linder, Klaus Hertting, Fabian Stahl, Julian Chun, Hitoshi Hachiya, Dietmar Bänsch, Matthias Antz, Karl-Heinz Kuck.   

Abstract

BACKGROUND: Catheters are typically stiff and incorporate a pull-wire mechanism to allow tip deflection. While standing at the patient's side, the operator manually navigates the catheter in the heart using fluoroscopic guidance. METHODS AND
RESULTS: A total of 42 patients (32 female; mean age, 55+/-15 years) underwent ablation of common-type (slow/fast) or uncommon-type (slow/slow) atrioventricular nodal reentrant tachycardia (AVNRT) with the use of the magnetic navigation system Niobe (Stereotaxis, Inc). It consists of 2 computer-controlled permanent magnets located on opposite sides of the patient, which create a steerable external magnetic field (0.08 T). A small magnet embedded in the catheter tip causes the catheter to align and to be steered by the external magnetic field. A motor drive advances or retracts the catheter, enabling complete remote navigation. Radiofrequency current was applied with the use of a remote-controlled 4-mm, solid-tip, magnetic navigation-enabled catheter (55 degrees C, maximum 40 W, 60 seconds) in all patients. The investigators, who were situated in the control room, performed the ablation using a mean of 7.2+/-4.7 radiofrequency current applications (mean fluoroscopy time, 8.9+/-6.2 minutes; procedure duration, 145+/-43 minutes). Slow pathway ablation was achieved in 15 patients, whereas slow pathway modulation was the end point in the remaining patients. There were no complications.
CONCLUSIONS: The Niobe magnetic navigation system is a new platform technology allowing remote-controlled navigation of an ablation catheter. In conjunction with a motor drive unit, this system was used successfully to perform completely remote-controlled mapping and ablation in patients with AVNRT.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15023876     DOI: 10.1161/01.CIR.0000125126.83579.1B

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  58 in total

Review 1.  The art of war: Innate and adaptive immune responses.

Authors:  P W Dempsey; S A Vaidya; G Cheng
Journal:  Cell Mol Life Sci       Date:  2003-12       Impact factor: 9.261

Review 2.  [New therapy possibilities for arrhythmias using catheter ablation].

Authors:  S Ernst; K-H Kuck
Journal:  Internist (Berl)       Date:  2006-10       Impact factor: 0.743

3.  Remote-controlled magnetic ablation of a right anterolateral accessory pathway - the superior caval vein approach.

Authors:  Julian Kyoung-Ryul Chun; Boris Schmidt; Karl-Heinz Kuck; Sabine Ernst
Journal:  J Interv Card Electrophysiol       Date:  2006-10-03       Impact factor: 1.900

4.  Successful ablation of a concealed parahisian accessory pathway using a remote magnetic navigation system following failure by conventional methods.

Authors:  Darryl R Davis; Anthony S Tang; David H Birnie; Michael H Gollob
Journal:  J Interv Card Electrophysiol       Date:  2006-11-16       Impact factor: 1.900

5.  Magnetic versus manual guidewire manipulation in neuroradiology: in vitro results.

Authors:  T Krings; J Finney; P Niggemann; P Reinacher; N Lück; A Drexler; J Lovell; A Meyer; R Sehra; P Schauerte; M Reinges; F J Hans; A Thron
Journal:  Neuroradiology       Date:  2006-04-19       Impact factor: 2.804

6.  Factors affecting error in integration of electroanatomic mapping with CT and MR imaging during catheter ablation of atrial fibrillation.

Authors:  E Kevin Heist; Jianping Chevalier; Godtfred Holmvang; Jagmeet P Singh; Patrick T Ellinor; David J Milan; Andre D'Avila; Theofanie Mela; Jeremy N Ruskin; Moussa Mansour
Journal:  J Interv Card Electrophysiol       Date:  2007-01-25       Impact factor: 1.900

Review 7.  Non-invasive genetic imaging for molecular and cell therapies of cancer.

Authors:  C Belmar; P-W So; G Vassaux; V Moleiro-Sanemeterio; P Martín-Duque
Journal:  Clin Transl Oncol       Date:  2007-11       Impact factor: 3.405

Review 8.  Magnetic and robotic navigation for catheter ablation: "joystick ablation".

Authors:  Sabine Ernst
Journal:  J Interv Card Electrophysiol       Date:  2008-06-07       Impact factor: 1.900

Review 9.  Catheter ablation - new developments in robotics.

Authors:  K R Julian Chun; Boris Schmidt; Bülent Köktürk; Roland Tilz; Alexander Fürnkranz; Melanie Konstantinidou; Erik Wissner; Andreas Metzner; Feifan Ouyang; Karl-Heinz Kuck
Journal:  Herz       Date:  2008-12       Impact factor: 1.443

10.  A streamlined, anchored, anatomical approach to ablation of atrioventricular nodal reentry tachycardia: preliminary report of the first 25 cases.

Authors:  J Rod Gimbel
Journal:  J Interv Card Electrophysiol       Date:  2005-03       Impact factor: 1.900

View more