A megavoltage scatter correction technique for cone-beam CT images acquired during VMAT delivery.

C J Boylan1, T E Marchant, J Stratford, J Malik, A Choudhury, R Shrimali, J Rodgers, C G Rowbottom.   

Abstract

Kilovoltage cone-beam CT (kV CBCT) can be acquired during the delivery of volumetric modulated arc therapy (VMAT), in order to obtain an image of the patient during treatment. However, the quality of such CBCTs is degraded by megavoltage (MV) scatter from the treatment beam onto the imaging panel. The objective of this paper is to introduce a novel MV scatter correction method for simultaneous CBCT during VMAT, and to investigate its effectiveness when compared to other techniques. The correction requires the acquisition of a separate set of images taken during VMAT delivery, while the kV beam is off. These images--which contain only the MV scatter contribution on the imaging panel--are then used to correct the corresponding kV/MV projections. To test this method, CBCTs were taken of an image quality phantom during VMAT delivery and measurements of contrast to noise ratio were made. Additionally, the correction was applied to the datasets of three VMAT prostate patients, who also received simultaneous CBCTs. The clinical image quality was assessed using a validated scoring system, comparing standard CBCTs to the uncorrected simultaneous CBCTs and a variety of correction methods. Results show that the correction is able to recover some of the low and high-contrast signal to noise ratio lost due to MV scatter. From the patient study, the corrected CBCT scored significantly higher than the uncorrected images in terms of the ability to identify the boundary between the prostate and surrounding soft tissue. In summary, a simple MV scatter correction method has been developed and, using both phantom and patient data, is shown to improve the image quality of simultaneous CBCTs taken during VMAT delivery.

Entities:  

Mesh:

Year:  2012        PMID: 22617805     DOI: 10.1088/0031-9155/57/12/3727

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Evaluating the image quality of cone beam CT acquired during rotational delivery.

Authors:  S A Yoganathan; K J Maria Das; K Maria Midunvaleja; D Gowtham Raj; Arpita Agarwal; J Velmurugan; Shaleen Kumar
Journal:  Br J Radiol       Date:  2015-07-30       Impact factor: 3.039

2.  A Bayesian approach for three-dimensional markerless tumor tracking using kV imaging during lung radiotherapy.

Authors:  Chun-Chien Shieh; Vincent Caillet; Michelle Dunbar; Paul J Keall; Jeremy T Booth; Nicholas Hardcastle; Carol Haddad; Thomas Eade; Ilana Feain
Journal:  Phys Med Biol       Date:  2017-03-21       Impact factor: 3.609

3.  A moving blocker-based strategy for simultaneous megavoltage and kilovoltage scatter correction in cone-beam computed tomography image acquired during volumetric modulated arc therapy.

Authors:  Luo Ouyang; Huichen Pam Lee; Jing Wang
Journal:  Radiother Oncol       Date:  2015-05-27       Impact factor: 6.280

4.  Concurrent kilovoltage CBCT imaging and megavoltage beam delivery: suppression of cross-scatter with 2D antiscatter grids and grid-based scatter sampling.

Authors:  Farhang Bayat; Mohamed Elsayed Eldib; Brian Kavanagh; Moyed Miften; Cem Altunbas
Journal:  Phys Med Biol       Date:  2022-08-09       Impact factor: 4.174

5.  Megavoltage cross-scatter rejection and correction using 2D antiscatter grids in kilovoltage CBCT imaging.

Authors:  Farhang Bayat; Mohamed Elsayed Eldib; Cem Altunbas
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

6.  Quantification and correction of the scattered X-rays from a megavoltage photon beam to a linac-mounted kilovoltage imaging subsystem.

Authors:  Hiraku Iramina; Mitsuhiro Nakamura; Yuki Miyabe; Nobutaka Mukumoto; Tomohiro Ono; Hideaki Hirashima; Takashi Mizowaki
Journal:  BJR Open       Date:  2020-12-11

7.  Intrafraction 4D-cone beam CT acquired during volumetric arc radiotherapy delivery: kV parameter optimization and 4D motion accuracy for lung stereotactic body radiotherapy (SBRT) patients.

Authors:  Jian Liang; Danielle Lack; Jun Zhou; Qiang Liu; Inga Grills; Di Yan
Journal:  J Appl Clin Med Phys       Date:  2019-11-01       Impact factor: 2.102

8.  Image quality of 4D in-treatment CBCT acquired during lung SBRT using FFF beam: a phantom study.

Authors:  Jihun Kim; Ki Chang Keum; Ho Lee; Chae-Seon Hong; Kwangwoo Park; Jin Sung Kim
Journal:  Radiat Oncol       Date:  2020-09-25       Impact factor: 3.481

9.  Image quality evaluation of intra-irradiation cone-beam computed tomography acquired during one- and two-arc prostate volumetric-modulated arc therapy delivery: A phantom study.

Authors:  Hiraku Iramina; Ayaka Kitamura; Mitsuhiro Nakamura; Takashi Mizowaki
Journal:  J Appl Clin Med Phys       Date:  2020-11-16       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.