Literature DB >> 22585546

In vivo O-Space imaging with a dedicated 12 cm Z2 insert coil on a human 3T scanner using phase map calibration.

Jason P Stockmann1, Gigi Galiana, Leo Tam, Christoph Juchem, Terence W Nixon, R Todd Constable.   

Abstract

Recently, spatial encoding with nonlinear magnetic fields has drawn attention for its potential to achieve faster gradient switching within safety limits, tailored resolution in regions of interest, and improved parallel imaging using encoding fields that complement the sensitivity profiles of radio frequency receive arrays. Proposed methods can broadly be divided into those that use phase encoding (Cartesian-trajectory PatLoc and COGNAC) and those that acquire nonlinear projections (O-Space, Null space imaging, radial PatLoc, and 4D-RIO). Nonlinear projection data are most often reconstructed with iterative algorithms that backproject data using the full encoding matrix. Just like conventional radial sequences that use linear spatial encoding magnetic fields, nonlinear projection methods are more sensitive than phase encoding methods to imperfect calibration of the encoding fields. In this work, voxel-wise phase evolution is mapped at each acquired point in an O-Space trajectory using a variant of chemical shift imaging, capturing all spin dynamics caused by encoding fields, eddy currents, and pulse timing. Phase map calibration is then applied to data acquired from a high-power, 12 cm, Z2 insert coil with an eight-channel radio frequency transmit-receive array on a 3T human scanner. We show the first experimental proof-of-concept O-Space images on in vivo and phantom samples, paving the way for more in-depth exploration of O-Space and similar imaging methods.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22585546      PMCID: PMC3491108          DOI: 10.1002/mrm.24282

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  33 in total

1.  Adaptive reconstruction of phased array MR imagery.

Authors:  D O Walsh; A F Gmitro; M W Marcellin
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

2.  Localization by nonlinear phase preparation and k-space trajectory design.

Authors:  Walter R T Witschey; Chris A Cocosco; Daniel Gallichan; Gerrit Schultz; Hans Weber; Anna Welz; Jürgen Hennig; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2011-11-29       Impact factor: 4.668

3.  Iterative reconstruction algorithms.

Authors:  G T Herman; A Lent
Journal:  Comput Biol Med       Date:  1976-10       Impact factor: 4.589

4.  Reconstruction of MRI data encoded with arbitrarily shaped, curvilinear, nonbijective magnetic fields.

Authors:  Gerrit Schultz; Peter Ullmann; Heinrich Lehr; Anna M Welz; Jürgen Hennig; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2010-09-16       Impact factor: 4.668

5.  Robust spatially selective excitation using radiofrequency pulses adapted to the effective spatially encoding magnetic fields.

Authors:  Johannes T Schneider; Martin Haas; Wolfgang Ruhm; Jürgen Hennig; Peter Ullmann
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

6.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

7.  Simultaneously driven linear and nonlinear spatial encoding fields in MRI.

Authors:  Daniel Gallichan; Chris A Cocosco; Andrew Dewdney; Gerrit Schultz; Anna Welz; Jürgen Hennig; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

8.  Radial imaging with multipolar magnetic encoding fields.

Authors:  Gerrit Schultz; Hans Weber; Daniel Gallichan; Walter R T Witschey; Anna M Welz; Chris A Cocosco; Jürgen Hennig; Maxim Zaitsev
Journal:  IEEE Trans Med Imaging       Date:  2011-08-12       Impact factor: 10.048

9.  Spin dephasing under nonlinear gradients: implications for imaging and field mapping.

Authors:  Gigi Galiana; Jason P Stockmann; Leo Tam; R Todd Constable
Journal:  Magn Reson Med       Date:  2011-07-14       Impact factor: 4.668

Review 10.  Parallel magnetic resonance imaging.

Authors:  David J Larkman; Rita G Nunes
Journal:  Phys Med Biol       Date:  2007-03-09       Impact factor: 3.609

View more
  15 in total

1.  Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine.

Authors:  Shu Li; Cheong Chan; Jason P Stockmann; Hemant Tagare; Ganesh Adluru; Leo K Tam; Gigi Galiana; R Todd Constable; Sebastian Kozerke; Dana C Peters
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

2.  Experimental O-space turbo spin echo imaging.

Authors:  Haifeng Wang; Leo Tam; Emre Kopanoglu; Dana C Peters; R Todd Constable; Gigi Galiana
Journal:  Magn Reson Med       Date:  2015-05-15       Impact factor: 4.668

3.  O-space with high resolution readouts outperforms radial imaging.

Authors:  Haifeng Wang; Leo Tam; Emre Kopanoglu; Dana C Peters; R Todd Constable; Gigi Galiana
Journal:  Magn Reson Imaging       Date:  2016-11-20       Impact factor: 2.546

4.  Multiecho acquisition of O-space data.

Authors:  Gigi Galiana; Dana Peters; Leo Tam; R Todd Constable
Journal:  Magn Reson Med       Date:  2014-01-23       Impact factor: 4.668

5.  Pseudo-random center placement O-space imaging for improved incoherence compressed sensing parallel MRI.

Authors:  Leo K Tam; Gigi Galiana; Jason P Stockmann; Hemant Tagare; Dana C Peters; R Todd Constable
Journal:  Magn Reson Med       Date:  2014-07-17       Impact factor: 4.668

6.  Fast rotary nonlinear spatial acquisition (FRONSAC) imaging.

Authors:  Haifeng Wang; Leo K Tam; R Todd Constable; Gigi Galiana
Journal:  Magn Reson Med       Date:  2015-05-07       Impact factor: 4.668

7.  Multi-slice MRI with the dynamic multi-coil technique.

Authors:  Christoph Juchem; Omar M Nahhass; Terence W Nixon; Robin A de Graaf
Journal:  NMR Biomed       Date:  2015-09-30       Impact factor: 4.044

8.  Radiofrequency pulse design using nonlinear gradient magnetic fields.

Authors:  Emre Kopanoglu; R Todd Constable
Journal:  Magn Reson Med       Date:  2014-09-09       Impact factor: 4.668

9.  Two-dimensional imaging in a lightweight portable MRI scanner without gradient coils.

Authors:  Clarissa Zimmerman Cooley; Jason P Stockmann; Brandon D Armstrong; Mathieu Sarracanie; Michael H Lev; Matthew S Rosen; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-03-25       Impact factor: 4.668

10.  Design of sparse Halbach magnet arrays for portable MRI using a genetic algorithm.

Authors:  Clarissa Zimmerman Cooley; Melissa W Haskell; Stephen F Cauley; Charlotte Sappo; Cristen D Lapierre; Christopher G Ha; Jason P Stockmann; Lawrence L Wald
Journal:  IEEE Trans Magn       Date:  2017-10-23       Impact factor: 1.700

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.