Literature DB >> 22579529

3D-imaging of the knee with an optimized 3D-FSE-sequence and a 15-channel knee-coil.

Mike Notohamiprodjo1, Annie Horng, Bernhard Kuschel, Dominik Paul, Guobin Li, Jose G Raya, Maximilian F Reiser, Christian Glaser.   

Abstract

OBJECTIVES: To evaluate the clinical usefulness of an optimized 3D-Fast-Spin-Echo-sequence (3D-SPACE) in combination with a 15-channel knee-coil for 3D-imaging of the knee at 3T.
METHODS: 15 volunteers and 50 consecutive patients were examined at 3 T with fat-saturated moderately T2-weighted 3D-SPACE (Voxel-size (VS): 0.6 mm×0.5 mm×0.5 mm/acquisition-time (AT) 10:44 min) using a 15-channel knee-coil. Flip angle optimization and radial k-space reordering were applied. Signal- and contrast-to-noise-ratios (SNR, CNR) were compared to non-optimized 3D-SPACE (8-channel knee-coil) and conventional 2D-FSE (VS: 0.4 mm×0.4 mm×3 mm/total AT: 12 min). Two radiologists independently rated depiction of internal knee structures and assessed detection and depiction of cartilage and meniscus abnormalities compared to conventional 2D-FSE-sequences. Sensitivity and specificity were calculated for a subgroup with arthroscopy as reference standard. Statistical analysis was performed with paired t-tests, confidence intervals and weighted-κ-coefficients.
RESULTS: SNR and CNR particularly of fluid/cartilage of optimized 3D-SPACE were significantly higher (p<0.05) than of the non-optimized 3D-sequence and conventional 2D-sequence. Blurring and image inhomogeneity were reduced in the optimized sequence. The thin slice-thickness was beneficial for depiction of problematical anatomical structures such as meniscal roots. 3D-SPACE showed significantly higher diagnostic confidence (p<0.05) for diagnosis of cartilage lesions of the femoral trochlea. Overall sensitivity and specificity of 3D-SPACE and 2D-FSE for cartilage lesions was 82.3%/80.2% and 79.4%/84.2% and 100%/86.4% and 92.3%/81.8% for meniscus lesions.
CONCLUSIONS: Optimized 3D-SPACE provides significantly higher signal and contrast compared to conventional 2D-FSE, particularly for fluid and cartilage, leading to improved diagnostic confidence, particularly in problematic areas, such as the femoral trochlea.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22579529     DOI: 10.1016/j.ejrad.2012.04.020

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  9 in total

1.  Routine clinical knee MR reports: comparison of diagnostic performance at 1.5 T and 3.0 T for assessment of the articular cartilage.

Authors:  Jacob C Mandell; Jeffrey A Rhodes; Nehal Shah; Glenn C Gaviola; Andreas H Gomoll; Stacy E Smith
Journal:  Skeletal Radiol       Date:  2017-07-17       Impact factor: 2.199

2.  [Morphological and functional cartilage imaging].

Authors:  C Rehnitz; M-A Weber
Journal:  Orthopade       Date:  2015-04       Impact factor: 1.087

3.  CAIPIRINHA accelerated SPACE enables 10-min isotropic 3D TSE MRI of the ankle for optimized visualization of curved and oblique ligaments and tendons.

Authors:  Vivek Kalia; Benjamin Fritz; Rory Johnson; Wesley D Gilson; Esther Raithel; Jan Fritz
Journal:  Eur Radiol       Date:  2017-01-23       Impact factor: 5.315

4.  Can a single isotropic 3D fast spin echo sequence replace three-plane standard proton density fat-saturated knee MRI at 1.5 T?

Authors:  B Pass; P Robinson; R Hodgson; A J Grainger
Journal:  Br J Radiol       Date:  2015-06-12       Impact factor: 3.039

5.  [Morphological and functional cartilage imaging].

Authors:  C Rehnitz; M-A Weber
Journal:  Radiologe       Date:  2014-06       Impact factor: 0.635

6.  3T MRI of the knee with optimised isotropic 3D sequences: Accurate delineation of intra-articular pathology without prolonged acquisition times.

Authors:  Osamah M Abdulaal; Louise Rainford; Peter MacMahon; Eoin Kavanagh; Marie Galligan; James Cashman; Allison McGee
Journal:  Eur Radiol       Date:  2017-04-21       Impact factor: 5.315

7.  Clinical utility of fat-suppressed 3-dimensional controlled aliasing in parallel imaging results in higher acceleration sampling perfection with application optimized contrast using different flip angle evolutions MRI of the knee in adults.

Authors:  Seungho Lee; Guen Young Lee; Sujin Kim; Yong-Beom Park; Han-Jun Lee
Journal:  Br J Radiol       Date:  2020-06-24       Impact factor: 3.039

8.  Feasibility of an accelerated 2D-multi-contrast knee MRI protocol using deep-learning image reconstruction: a prospective intraindividual comparison with a standard MRI protocol.

Authors:  Judith Herrmann; Gabriel Keller; Sebastian Gassenmaier; Dominik Nickel; Gregor Koerzdoerfer; Mahmoud Mostapha; Haidara Almansour; Saif Afat; Ahmed E Othman
Journal:  Eur Radiol       Date:  2022-04-07       Impact factor: 7.034

9.  Diagnostic performance of 3D SPACE for comprehensive knee joint assessment at 3 T.

Authors:  Pieter Van Dyck; Jan L Gielen; Filip M Vanhoenacker; Eline De Smet; Kristien Wouters; Lieven Dossche; Paul M Parizel
Journal:  Insights Imaging       Date:  2012-10-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.