OBJECTIVE: To evaluate volumetric changes of parotid glands (PGs) during intensity-modulated radiotherapy (IMRT) in head and neck cancer patients. METHODS: During IMRT all patients underwent kilovolt cone-beam CT (CBCT) scans to verify the set-up positioning in a protocol study. On each CBCT scan, the PGs were retrospectively contoured and evaluated with a dose-volume histogram. RESULTS: From February to June 2011, 10 patients were enrolled. 140 CBCT scans were registered (280 PGs): for each patient, a median of 14 CBCT scans were performed (range 14-16). At the start of radiation, the average volume for ipsilateral PGs (iPGs) was 18.77 ml (range 12.9-31.2 ml), whereas for contralateral PGs (cPGs) it was 16.63 ml (range 8.3-28.7 ml). At the last CBCT scan, the average volume loss was 43.5% and 44.0% for the iPG and cPG, respectively. When we analysed the percentage of volume loss, we observed that the volume decreased by linear regression (r(2)=0.92 for iPG; r(2)=0.91 for cPG), with an average volume loss rate of 1.5% per day for both PGs. During the third week of treatment the volume of both PGs reduced by 24-30%. CONCLUSION: Our data show that, during IMRT, the shrinkage of PGs should be taken into account. A replan could be indicated in the third week of radiotherapy.
OBJECTIVE: To evaluate volumetric changes of parotid glands (PGs) during intensity-modulated radiotherapy (IMRT) in head and neck cancerpatients. METHODS: During IMRT all patients underwent kilovolt cone-beam CT (CBCT) scans to verify the set-up positioning in a protocol study. On each CBCT scan, the PGs were retrospectively contoured and evaluated with a dose-volume histogram. RESULTS: From February to June 2011, 10 patients were enrolled. 140 CBCT scans were registered (280 PGs): for each patient, a median of 14 CBCT scans were performed (range 14-16). At the start of radiation, the average volume for ipsilateral PGs (iPGs) was 18.77 ml (range 12.9-31.2 ml), whereas for contralateral PGs (cPGs) it was 16.63 ml (range 8.3-28.7 ml). At the last CBCT scan, the average volume loss was 43.5% and 44.0% for the iPG and cPG, respectively. When we analysed the percentage of volume loss, we observed that the volume decreased by linear regression (r(2)=0.92 for iPG; r(2)=0.91 for cPG), with an average volume loss rate of 1.5% per day for both PGs. During the third week of treatment the volume of both PGs reduced by 24-30%. CONCLUSION: Our data show that, during IMRT, the shrinkage of PGs should be taken into account. A replan could be indicated in the third week of radiotherapy.
Authors: H Loo; J Fairfoul; A Chakrabarti; J C Dean; R J Benson; S J Jefferies; N G Burnet Journal: Clin Oncol (R Coll Radiol) Date: 2010-10-06 Impact factor: 4.126
Authors: Dirk Verellen; Mark De Ridder; Nadine Linthout; Koen Tournel; Guy Soete; Guy Storme Journal: Nat Rev Cancer Date: 2007-12 Impact factor: 60.716
Authors: Eric K Hansen; M Kara Bucci; Jeanne M Quivey; Vivian Weinberg; Ping Xia Journal: Int J Radiat Oncol Biol Phys Date: 2005-10-26 Impact factor: 7.038
Authors: Eliana M Vásquez Osorio; Mischa S Hoogeman; Abrahim Al-Mamgani; David N Teguh; Peter C Levendag; Ben J M Heijmen Journal: Int J Radiat Oncol Biol Phys Date: 2008-03-01 Impact factor: 7.038
Authors: R Mazzola; F Ricchetti; A Fiorentino; S Fersino; N Giaj Levra; S Naccarato; G Sicignano; S Albanese; G Di Paola; D Alterio; R Ruggieri; F Alongi Journal: Br J Radiol Date: 2014-10-28 Impact factor: 3.039
Authors: A Fiorentino; M Cozzolino; R Caivano; P Pedicini; C Chiumento; C Oliviero; S Clemente; V Fusco Journal: Clin Transl Oncol Date: 2012-10-13 Impact factor: 3.405