Literature DB >> 16256277

Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer.

Eric K Hansen1, M Kara Bucci, Jeanne M Quivey, Vivian Weinberg, Ping Xia.   

Abstract

PURPOSE: Many patients with head-and-neck (H&N) cancer have tumor shrinkage and/or weight loss during the course of radiotherapy. We conducted this retrospective study to determine the dosimetric effects of repeat computed tomography (CT) imaging and replanning during the course of intensity-modulated radiotherapy (IMRT) on both normal tissues and target volumes. METHODS AND MATERIALS: A retrospective chart review identified 13 patients with H&N cancer treated with IMRT who had repeat CT imaging and replanning during the course of radiotherapy. The first IMRT plan for each patient was generated based on the original planning CT scan acquired before the start of treatment. Because of tumor shrinkage or weight loss during radiotherapy, a second CT scan was acquired, and a new plan was generated and used to complete the course of IMRT. CT-CT fusion was used to correct patient positioning differences between the scans. By using a commercial inverse IMRT planning system, a hybrid IMRT plan was generated for each patient by applying the beam configurations of the first IMRT plan (including the intensity profile of each beam) to the anatomy of the second CT scan. The dose-volume histograms of the actual and hybrid IMRT plans were compared using analysis of variance methods for repeated measures.
RESULTS: All patients had locally advanced, nonmetastatic Stage III or IV disease, including 6 nasopharynx, 6 oropharynx, and 1 unknown primary site. All patients were treated with concurrent platinum-based chemotherapy. When replanning vs. not replanning was compared, the hybrid IMRT plans (without replanning) demonstrated reduced doses to target volumes and increased doses to critical structures. The doses to 95% (D95) of the planning target volumes of the gross tumor volume (PTVGTV) and the clinical target volume (PTVCTV) were reduced in 92% of patients, by 0.8-6.3 Gy (p=0.02) and 0.2-7.4 Gy (p=0.003), respectively. The maximum dose (Dmax) to the spinal cord increased in all patients (range, 0.2-15.4 Gy; p=0.003) and the brainstem Dmax increased in 85% of patients without replanning (range, 0.6-8.1 Gy; p=0.007).
CONCLUSIONS: Repeat CT imaging and replanning during the course of IMRT for selected patients with H&N cancer is essential to identify dosimetric changes and to ensure adequate doses to target volumes and safe doses to normal tissues. Future prospective studies with larger sample sizes will help to determine criteria for repeat CT imaging and IMRT replanning for H&N cancer patients undergoing radiotherapy.

Entities:  

Mesh:

Year:  2005        PMID: 16256277     DOI: 10.1016/j.ijrobp.2005.07.957

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  119 in total

Review 1.  Current progress in adaptive radiation therapy for head and neck cancer.

Authors:  David L Schwartz
Journal:  Curr Oncol Rep       Date:  2012-04       Impact factor: 5.075

2.  Image-based modeling of tumor shrinkage in head and neck radiation therapy.

Authors:  Ming Chao; Yaoqin Xie; Eduardo G Moros; Quynh-Thu Le; Lei Xing
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

3.  Pattern and predictors of volumetric change of parotid glands during intensity modulated radiotherapy.

Authors:  G Sanguineti; F Ricchetti; O Thomas; B Wu; T McNutt
Journal:  Br J Radiol       Date:  2013-09-12       Impact factor: 3.039

Review 4.  Clinical application of intensity-modulated radiotherapy for head and neck cancer.

Authors:  O Ballivy; R Galiana Santamaría; A Lozano Borbalas; F Guedea Edo
Journal:  Clin Transl Oncol       Date:  2008-07       Impact factor: 3.405

5.  Is it necessary to repeat CT imaging and replanning during the course of intensity-modulated radiation therapy for locoregionally advanced nasopharyngeal carcinoma?

Authors:  Chuanben Chen; Xiang Lin; Jianji Pan; Zhaodong Fei; Lisha Chen; Penggang Bai
Journal:  Jpn J Radiol       Date:  2013-06-09       Impact factor: 2.374

6.  MRI-guided radiotherapy for head and neck cancer: initial clinical experience.

Authors:  A M Chen; S Hsu; J Lamb; Y Yang; N Agazaryan; M L Steinberg; D A Low; M Cao
Journal:  Clin Transl Oncol       Date:  2017-06-13       Impact factor: 3.405

7.  Technical note: DIRART--A software suite for deformable image registration and adaptive radiotherapy research.

Authors:  Deshan Yang; Scott Brame; Issam El Naqa; Apte Aditya; Yu Wu; S Murty Goddu; Sasa Mutic; Joseph O Deasy; Daniel A Low
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

8.  Error in the parotid contour delineated using computed tomography images rather than magnetic resonance images during radiotherapy planning for nasopharyngeal carcinoma.

Authors:  Chengxin Liu; Xudong Kong; Guanzhong Gong; Tonghai Liu; Baosheng Li; Yong Yin
Journal:  Jpn J Radiol       Date:  2014-02-21       Impact factor: 2.374

9.  Cone-beam computed tomography dose monitoring during intensity-modulated radiotherapy in head and neck cancer: parotid glands.

Authors:  A Fiorentino; M Cozzolino; R Caivano; P Pedicini; C Chiumento; C Oliviero; S Clemente; V Fusco
Journal:  Clin Transl Oncol       Date:  2012-10-13       Impact factor: 3.405

10.  Recent advances in image-guided radiotherapy for head and neck carcinoma.

Authors:  Sameer K Nath; Daniel R Simpson; Brent S Rose; Ajay P Sandhu
Journal:  J Oncol       Date:  2009-07-29       Impact factor: 4.375

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.