Literature DB >> 22559332

Identification of biomechanical properties of the cornea: the ocular response analyzer.

Naim Terai1, Frederik Raiskup, Michael Haustein, Lutz E Pillunat, Eberhard Spoerl.   

Abstract

PURPOSE: Several methods have been devised for measuring geometric parameters of the cornea but, until now, the biomechanics of the cornea have been largely ignored. The relatively new Ocular Response Analyzer (ORA) provides such biomechanical information. In order to correctly interpret the underlying biomechanics of ORA data, we review reported ORA measurements and provide a compendium of factors influencing these measurements, with discussion of possible explanations for ORA measurement results.
METHODS: This review comprised a literature search using "ocular response analyzer" and "ocular response analyser" as keywords. We reviewed and compared reported results from recent ORA studies so obtained, with an eye to understanding corneal biomechanics.
RESULTS: Several ORA biomechanical parameters of the cornea - corneal hysteresis (CH) and corneal resistant factor (CRF) - characterize the viscoelastic properties of the cornea, especially those of the ground substance. The impact on CH and CRF values of various independent factors, e.g. intraocular pressure (IOP), age, central corneal thickness (CCT), and corneal swelling, are discussed. The impact on CH and CRF of treatment-related structural changes of the cornea, i.e. those occurring after refractive surgical procedures, placement of intracorneal rings, and collagen crosslinking (CXL), as well as pathological changes of the cornea, e.g. those resulting from keratoconus, edema, and glaucoma, are discussed.
CONCLUSIONS: Changes in CRF and CH may be reflective of structural changes in the ground substance of the cornea. Thus, ORA provides invaluable information for delineating biomechanical conditions pertaining to the cornea, with special regard to ocular diseases, e.g. keratoconus and glaucoma.

Entities:  

Mesh:

Year:  2012        PMID: 22559332     DOI: 10.3109/02713683.2012.669007

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  63 in total

1.  Intraocular pressure measurement with Corvis ST in comparison with applanation tonometry and Tomey non-contact tonometry.

Authors:  Jan Luebke; L Bryniok; M Neuburger; J F Jordan; D Boehringer; T Reinhard; T Wecker; A Anton
Journal:  Int Ophthalmol       Date:  2019-04-09       Impact factor: 2.031

2.  [New aspects on biomechanics of the cornea in keratoconus].

Authors:  Z Gatzioufas; B Seitz
Journal:  Ophthalmologe       Date:  2013-09       Impact factor: 1.059

3.  Cataract surgery on post radial keratotomy patients.

Authors:  Alessandro Meduri; Mario Urso; Giuseppe A Signorino; Miguel Rechichi; Cosimo Mazzotta; Stephen Kaufman
Journal:  Int J Ophthalmol       Date:  2017-07-18       Impact factor: 1.779

4.  [Early recognition of keratoconus by biomechanical characteristics of the cornea].

Authors:  D Böhringer; M Neuburger; T Reinhard
Journal:  Ophthalmologe       Date:  2014-01       Impact factor: 1.059

5.  Comparative analysis of biomechanical parameters of the corneas following Descemet membrane endothelial keratoplasty and contralateral healthy corneas.

Authors:  Natalya F Shilova; Yoav Nahum; Avital Adler; Irit Bahar; Boris E Malyugin; Natalia S Anisimova; Eitan Livny
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-06-11       Impact factor: 3.117

Review 6.  [Dynamic Scheimpflug Analyzer (Corvis ST) for measurement of corneal biomechanical parameters : A praxis-related overview].

Authors:  R Herber; N Terai; K R Pillunat; F Raiskup; L E Pillunat; E Spörl
Journal:  Ophthalmologe       Date:  2018-08       Impact factor: 1.059

7.  Comparison of Diaton transpalpebral tonometer with applanation tonometry in keratoconus.

Authors:  Robert Pl Wisse; Natalie Peeters; Saskia M Imhof; Allegonda van der Lelij
Journal:  Int J Ophthalmol       Date:  2016-03-18       Impact factor: 1.779

8.  Synergic effect of corneal hysteresis and central corneal thickness in the risk of early-stage primary open-angle glaucoma progression.

Authors:  Maria A Jiménez-Santos; Federico Saénz-Francés; Rubén Sánchez-Jean; José María Martinez-de-la Casa; Julian García-Feijoo; Luis Jañez-Escalada
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-05-07       Impact factor: 3.117

9.  Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients.

Authors:  Emine Sen; Yasemin Tutuncu; Melike Balikoglu-Yilmaz; Ufuk Elgin; Dilek Berker; Faruk Ozturk; Serdar Guler
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-13       Impact factor: 3.117

10.  Corneal hysteresis and primary open angle glaucoma.

Authors:  Dascalescu Dana; Constantin Mihaela; Iancu Raluca; Cristea Miruna; Ionescu Catalina; Cioboata Miruna; Speranta Schmitzer; Corbu Catalina
Journal:  Rom J Ophthalmol       Date:  2015 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.