Literature DB >> 22539100

The effect of slice thickness on the assessment of bone defect volumes by the Cavalieri principle using cone beam computed tomography.

Omer Said Sezgin1, Saadettin Kayıpmaz, Bunyamin Sahin.   

Abstract

The purpose of this study was to investigate the possible effects of section thickness on volume estimations obtained by cone beam computed tomography. Intraosseal cavities representing bone defects on vestibular sides of the two dry sheep mandibles were scanned by a cone beam computed tomography system. Consecutive sections at 0.2, 0.6, 1, 1.4, and 2.2 mm thickness were used to estimate the volumes of the cavities using the Cavalieri principle of stereological methods. Estimated volumes are then compared with the volumes obtained by the Archimedean principle. In 0.2-, 0.6-, and 1-mm-thick slices, the volumes estimated by the Cavalieri principle did not differ from the volumes by the Archimedean principle (p > 0.05). The 0.2 mm slice-thickness group had the highest asymptotic significance value (p = 0.6). Although the thinnest slice appears to provide the most accurate values, slice thickness up to 1 mm can be chosen for volume calculations on CBCT images.

Entities:  

Mesh:

Year:  2013        PMID: 22539100      PMCID: PMC3553367          DOI: 10.1007/s10278-012-9480-8

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  19 in total

Review 1.  The benefit of stereology for quantitative radiology.

Authors:  N Roberts; M J Puddephat; V McNulty
Journal:  Br J Radiol       Date:  2000-07       Impact factor: 3.039

2.  Unbiased estimation of the liver volume by the Cavalieri principle using magnetic resonance images.

Authors:  Bünyamin Sahin; Mehmet Emirzeoglu; Ahmet Uzun; Lütfi Incesu; Yüksel Bek; Sait Bilgic; Süleyman Kaplan
Journal:  Eur J Radiol       Date:  2003-08       Impact factor: 3.528

3.  The effects of section thickness on the estimation of liver volume by the Cavalieri principle using computed tomography images.

Authors:  Mehmet Emirzeoglu; Bunyamin Sahin; Mustafa B Selcuk; Suleyman Kaplan
Journal:  Eur J Radiol       Date:  2005-12       Impact factor: 3.528

4.  Assessment of the optimum section thickness for the estimation of liver volume using magnetic resonance images: a stereological gold standard study.

Authors:  Bunyamin Sahin; Hayati Ergur
Journal:  Eur J Radiol       Date:  2005-08-19       Impact factor: 3.528

5.  Comparison of three methods for the estimation of total intracranial volume: stereologic, planimetric, and anthropometric approaches.

Authors:  Niyazi Acer; Bunyamin Sahin; Orhan Baş; Tolga Ertekin; Mustafa Usanmaz
Journal:  Ann Plast Surg       Date:  2007-01       Impact factor: 1.539

6.  Volumetric analysis of extraction sockets using cone beam computed tomography: a pilot study on ex vivo jaw bone.

Authors:  Jimoh Olubanwo Agbaje; Reinhilde Jacobs; Frederik Maes; Katleen Michiels; Daniel van Steenberghe
Journal:  J Clin Periodontol       Date:  2007-11       Impact factor: 8.728

7.  Dependence of computed tomography volume measurements upon section thickness: an application to human dry skulls.

Authors:  Bunyamin Sahin; Michael Mazonakis; Huseyin Akan; Suleyman Kaplan; Yuksel Bek
Journal:  Clin Anat       Date:  2008-09       Impact factor: 2.414

8.  Evaluation of cross-section airway configuration of obstructive sleep apnea.

Authors:  Takumi Ogawa; Reyes Enciso; Werner H Shintaku; Glenn T Clark
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-09-01

9.  Volumetric analysis of the mandibular condyle using cone beam computed tomography.

Authors:  Mehmet Bayram; Saadettin Kayipmaz; Omer Said Sezgin; Murat Küçük
Journal:  Eur J Radiol       Date:  2011-06-15       Impact factor: 3.528

10.  Estimation of the amniotic fluid volume using the Cavalieri method on ultrasound images.

Authors:  B Sahin; T Alper; A Kökçü; E Malatyalioglu; R Kosif
Journal:  Int J Gynaecol Obstet       Date:  2003-07       Impact factor: 3.561

View more
  7 in total

1.  Comparing different planimetric methods on volumetric estimations by using cone beam computed tomography.

Authors:  Alaettin Koç; Ömer Said Sezgin; Saadettin Kayıpmaz
Journal:  Radiol Med       Date:  2020-01-08       Impact factor: 3.469

2.  Is it possible to estimate volume of bone defects formed on dry sheep mandibles more practically by secondarily reconstructing section thickness of cone beam computed tomography images?

Authors:  Alaettin Koç; Sema Kaya
Journal:  Dentomaxillofac Radiol       Date:  2020-10-15       Impact factor: 2.419

3.  Accuracy of virtual models in the assessment of maxillary defects.

Authors:  Kıvanç Kamburoğlu; Şebnem Kurşun; Cenk Kılıç; Tuncer Özen
Journal:  Imaging Sci Dent       Date:  2015-03-13

4.  Assessment of slice thickness effect on visibility of inferior alveolar canal in cone beam computed tomography images.

Authors:  Daryoush Goodarzi Pour; Banafsheh Arzi; Ahmad Reza Shamshiri
Journal:  Dent Res J (Isfahan)       Date:  2016 Nov-Dec

5.  Accuracy and Reliability of Cone-Beam Computed Tomography for Linear and Volumetric Mandibular Condyle Measurements. A Human Cadaver Study.

Authors:  Verónica García-Sanz; Carlos Bellot-Arcís; Virginia Hernández; Pedro Serrano-Sánchez; Juan Guarinos; Vanessa Paredes-Gallardo
Journal:  Sci Rep       Date:  2017-09-20       Impact factor: 4.379

6.  Radiological and Morphometric Features of Canalis Sinuosus in Russian Population: Cone-Beam Computed Tomography Study.

Authors:  Avanesov Anatoly; Yuri Sedov; Evgeniya Gvozdikova; Oleg Mordanov; Liudmila Kruchinina; Karen Avanesov; Anna Vinogradova; Sergei Golub; Dalila Khaydar; Nguyen Giao Hoang; Hadi M Darawsheh
Journal:  Int J Dent       Date:  2019-12-16

7.  Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography.

Authors:  Anuraj Singh Kochhar; Maninder Singh Sidhu; Mona Prabhakar; Ritasha Bhasin; Gulsheen Kaur Kochhar; Himanshu Dadlani; Gianrico Spagnuolo; Viral Vijay Mehta
Journal:  Dent J (Basel)       Date:  2021-01-22
  7 in total