Literature DB >> 16112829

Assessment of the optimum section thickness for the estimation of liver volume using magnetic resonance images: a stereological gold standard study.

Bunyamin Sahin1, Hayati Ergur.   

Abstract

Estimation of liver volume using magnetic resonance (MR) images has been described previously. We have, however, not found a gold standard study, which analyzes the effect of section thickness on the estimation of liver volume. In the present study, five normal cadaveric livers were scanned in the horizontal plane using a 1.5 T MR machine (Signa 1.5T SYS#GEMSOW General Electronic, Wisconsin, USA). Consecutive sections at a thickness of 10, 7.5, 5 and 2.5 mm were used to estimate the total volume of the livers by means of the Cavalieri principle. The point counting and planimetry were used for the volume estimates. With a view to evaluating the accuracy of two techniques, all the estimations were done by the same observer. The estimated volumes concur with the actual volume of the livers obtained by the fluid displacement technique (p > 0.05). However, the section thickness has an over- or under-projection effect on the estimated volume. The obtained volume estimation results were analyzed to reveal the deviation principles of the estimates based on the section thickness. The most suitable section thickness for the liver volume estimation was assessed to be 4-5 mm. There were no significant differences between the estimation results of two methods (p > 0.05). The point-counting technique did, however, take less time than planimetry for estimating liver volume from MR images. Results also showed that the effect of section thickness on volume estimates using the two approaches could not be omitted and the values obtained could be calibrated using the proposed regression formula presented in this study.

Mesh:

Year:  2005        PMID: 16112829     DOI: 10.1016/j.ejrad.2005.07.006

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  22 in total

Review 1.  The use of design-based stereology to evaluate volumes and numbers in the liver: a review with practical guidelines.

Authors:  Ricardo Marcos; Rogério A F Monteiro; Eduardo Rocha
Journal:  J Anat       Date:  2012-02-01       Impact factor: 2.610

2.  Stereological evaluation of the volume and volume fraction of newborns' brain compartment and brain in magnetic resonance images.

Authors:  Mehtap Nisari; Tolga Ertekin; Ozlem Ozçelik; Serife Cınar; Selim Doğanay; Niyazi Acer
Journal:  Surg Radiol Anat       Date:  2012-04-18       Impact factor: 1.246

3.  Comparison of three methods for the estimation of the pituitary gland volume using magnetic resonance imaging: a stereological study.

Authors:  Tolga Ertekin; Niyazi Acer; Ahmet T Turgut; Kenan Aycan; Ozlem Ozçelik; Mehmet Turgut
Journal:  Pituitary       Date:  2011-03       Impact factor: 4.107

4.  The effect of slice thickness on the assessment of bone defect volumes by the Cavalieri principle using cone beam computed tomography.

Authors:  Omer Said Sezgin; Saadettin Kayıpmaz; Bunyamin Sahin
Journal:  J Digit Imaging       Date:  2013-02       Impact factor: 4.056

5.  Comparison of point counting and planimetry methods for the assessment of cerebellar volume in human using magnetic resonance imaging: a stereological study.

Authors:  Niyazi Acer; Bunyamin Sahin; Mustafa Usanmaz; Hakki Tatoğlu; Zöhre Irmak
Journal:  Surg Radiol Anat       Date:  2008-02-22       Impact factor: 1.246

6.  Volumetric evaluation of the relations among the cerebrum, cerebellum and brain stem in young subjects: a combination of stereology and magnetic resonance imaging.

Authors:  Nihat Ekinci; Niyazi Acer; Akcan Akkaya; Seref Sankur; Taner Kabadayi; Bünyamin Sahin
Journal:  Surg Radiol Anat       Date:  2008-05-14       Impact factor: 1.246

7.  The estimation of the volume of sheep mandibular defects using cone-beam computed tomography images and a stereological method.

Authors:  S Kayipmaz; O S Sezgin; S T Saricaoglu; O Bas; B Sahin; M Küçük
Journal:  Dentomaxillofac Radiol       Date:  2011-03       Impact factor: 2.419

8.  Comparison of two methods for the estimation of subcortical volume and asymmetry using magnetic resonance imaging: a methodological study.

Authors:  Tolga Ertekin; Niyazi Acer; Semra Içer; Ahmet T Ilıca
Journal:  Surg Radiol Anat       Date:  2012-11-10       Impact factor: 1.246

9.  A stereological study on the correlation of inferior turbinate hypertrophy and paranasal sinus disease.

Authors:  Ahmet Ural; Murat Songu; Zehra Hilal Adibelli; Huseyin Candan
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-01-04       Impact factor: 2.503

10.  Comparing different planimetric methods on volumetric estimations by using cone beam computed tomography.

Authors:  Alaettin Koç; Ömer Said Sezgin; Saadettin Kayıpmaz
Journal:  Radiol Med       Date:  2020-01-08       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.