Literature DB >> 15893441

The effects of section thickness on the estimation of liver volume by the Cavalieri principle using computed tomography images.

Mehmet Emirzeoglu1, Bunyamin Sahin, Mustafa B Selcuk, Suleyman Kaplan.   

Abstract

Estimation of liver volume using routine CT scans has been described previously. We have, however, not found a gold standard study which analyzes the effect of section thickness on the estimation of liver volume using CT images. In the present study, five normal livers obtained from cadavers were scanned using a Spiral CT Scanner (Xpress/GX Toshiba, Tocigi-Ken) in the horizontal plane. Consecutive sections at a thickness of 10, 5 and 1mm were used to estimate the total volume of the livers by means of the Cavalieri principle. With a view to evaluating inter-observer differences, liver volume was estimated by three observers. The estimated volume using the classical volume estimation formula did not concur with the actual volume of the livers obtained by the fluid displacement technique. The section thickness has an over- or under-projection effect on the estimated volume. The obtained volume estimation results were, therefore, calibrated using three different approaches. The volume obtained by the calibration formulae did not differ statistically from actual liver volumes (P<0.05). There were also no significant differences between the performers' estimates (P>0.05). Results showed that the effect of section thickness on the volume estimates could not be omitted and the obtained values could be calibrated using the proposed approaches presented in this study.

Entities:  

Mesh:

Year:  2005        PMID: 15893441     DOI: 10.1016/j.ejrad.2005.04.008

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  12 in total

1.  The effect of slice thickness on the assessment of bone defect volumes by the Cavalieri principle using cone beam computed tomography.

Authors:  Omer Said Sezgin; Saadettin Kayıpmaz; Bunyamin Sahin
Journal:  J Digit Imaging       Date:  2013-02       Impact factor: 4.056

2.  The estimation of the volume of sheep mandibular defects using cone-beam computed tomography images and a stereological method.

Authors:  S Kayipmaz; O S Sezgin; S T Saricaoglu; O Bas; B Sahin; M Küçük
Journal:  Dentomaxillofac Radiol       Date:  2011-03       Impact factor: 2.419

3.  Ex vivo orbital volumetry using stereology and CT imaging: A comparison with manual planimetry.

Authors:  Georgios Bontzos; Michael Mazonakis; Efrosini Papadaki; Thomas G Maris; Styliani Blazaki; Eleni E Drakonaki; Efstathios T Detorakis
Journal:  Eur Radiol       Date:  2018-08-22       Impact factor: 5.315

4.  A stereological study on the correlation of inferior turbinate hypertrophy and paranasal sinus disease.

Authors:  Ahmet Ural; Murat Songu; Zehra Hilal Adibelli; Huseyin Candan
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-01-04       Impact factor: 2.503

5.  Computed tomography liver volumetry using 3-dimensional image data in living donor liver transplantation: effects of the slice thickness on the volume calculation.

Authors:  Masatoshi Hori; Kenji Suzuki; Mark L Epstein; Richard L Baron
Journal:  Liver Transpl       Date:  2011-12       Impact factor: 5.799

6.  Efficient stereological approaches for the volumetry of a normal or enlarged spleen from MDCT images.

Authors:  Michalis Mazonakis; John Stratakis; John Damilakis
Journal:  Eur Radiol       Date:  2015-01-13       Impact factor: 5.315

7.  Is it possible to estimate volume of bone defects formed on dry sheep mandibles more practically by secondarily reconstructing section thickness of cone beam computed tomography images?

Authors:  Alaettin Koç; Sema Kaya
Journal:  Dentomaxillofac Radiol       Date:  2020-10-15       Impact factor: 2.419

8.  Stereological estimation of left-ventricular volumetric and functional parameters from multidetector-row computed tomography data.

Authors:  Michalis Mazonakis; Konstantin Pagonidis; Thomas Schlosser; Peter Hunold; John Damilakis; Jörg Barkhausen; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2008-03-20       Impact factor: 7.034

9.  Accuracy of virtual models in the assessment of maxillary defects.

Authors:  Kıvanç Kamburoğlu; Şebnem Kurşun; Cenk Kılıç; Tuncer Özen
Journal:  Imaging Sci Dent       Date:  2015-03-13

10.  Nasal Septal Deviation and Concha Bullosa - Do They Have an Impact on Maxillary Sinus Volumes and Prevalence of Maxillary Sinusitis?

Authors:  Iwona Kucybała; Konrad Adam Janik; Szymon Ciuk; Dawid Storman; Andrzej Urbanik
Journal:  Pol J Radiol       Date:  2017-03-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.