Literature DB >> 22527980

Terumo-Triplex grafts for total arch replacement: analysis of postoperative graft performance.

Toshihiro Ohata1, Hideki Ueda, Kazuya Kobayashi, Hirotsugu Fukuda, Yuji Miyamoto.   

Abstract

We evaluated the performance of Terumo-Triplex (TRP) with a large-diameter vascular graft sealed with non-biodegradable material in 48 patients who underwent total arch replacement under selective cerebral perfusion between 2004 and 2009. TRP grafts were used in 13 patients (T group), Gelseal graft in 15 (G group), Hemashield graft in 10 (H group) and Intergard graft in 10 (I group). The total tube drainage, time to tube removal, graft dilation ratio and inflammation were evaluated postoperatively. Cardiopulmonary bypass and selective cerebral perfusion times did not differ between groups. Two patients died in hospital. The total drain drainage was significantly lower in the T group (956 ± 156 ml) than in the H (2058 ± 403 ml, p = 0.001) or I (5959 ± 1027 ml, p = 0.01) groups. The time to tube removal was significantly lower in T group and G group than H and I group (T: 3.7 ± 0.4, G: 4.1 ± 0.4, H: 8.3 ± 1.6, I: 18.6 ± 3.6 days, T vs. H, I: p = 0.07, 0.0002, G vs. H, I: p = 0.004, <0.0001). The graft dilation ratio was significantly lower in T group than G group (T: 104 ± 4 vs. 130 ± 7 %, p = 0.001). The max C-reactive protein level was significantly lower in T group (16.2 ± 4.5 mg/dl) than in the G group (19.4 ± 3.2 mg/dl, p = 0.047), H (20.4 ± 4.1 mg/dl, p = 0.048), or I (20.5 ± 4.5 mg/dl, p = 0.013) groups. Maximum body temperature was also lower in the T group (38.2 ± 0.5 °C) than in the G (38.7 ± 0.4 °C, p = 0.011), H (38.9 ± 0.6 °C, p = 0.0087), and I (39.3 ± 0.7 °C, p = 0.0005). Thus, TRP graft might attenuate inflammatory response compared to the other sealed grafts for total arch replacement in patients with aortic arch aneurysm or dissection.

Entities:  

Mesh:

Year:  2012        PMID: 22527980     DOI: 10.1007/s10047-012-0646-4

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  7 in total

1.  Knitted dacron grafts used for abdominal aortic reconstruction: sizing references.

Authors:  M Alonso-Pérez; R J Segura; S Luján; E D Vidal; J A Cachaldora; J Vidal; J Sanchez
Journal:  Vasc Surg       Date:  2001 Nov-Dec

2.  Clinical experience with a new vascular graft free from biodegradable material.

Authors:  Atsushi Tamura; Atsushi Yamaguchi; Kouichi Yuri; Kenichiro Noguchi; Kazuhiro Naito; Hiroshi Nagano; Masaya Takahashi; Hideo Adachi
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-02-21

3.  New uncoated vascular prosthesis reduces mediastinal tube drainage after thoracic aortic surgery.

Authors:  Minoru Tabata; Tomoki Shimokawa; Toshihiro Fukui; Susumu Manabe; Yasunori Sato; Shuichiro Takanashi
Journal:  Ann Thorac Surg       Date:  2011-03       Impact factor: 4.330

4.  In vivo morphology of woven, collagen-sealed Dacron prostheses in the thoracic aorta.

Authors:  U Franke; M J Jurmann; K Uthoff; A Köhler; B Jurmann; T Wahlers; H G Borst
Journal:  Ann Thorac Surg       Date:  1997-10       Impact factor: 4.330

5.  Coated prostheses are associated with prolonged inflammation in aortic surgery: a cost analysis.

Authors:  Shunya Shindo; Shinya Motohashi; Masatake Katsu; Shigeaki Kaga; Hidenori Inoue; Masahiko Matsumoto
Journal:  Artif Organs       Date:  2008-01-15       Impact factor: 3.094

6.  Replacement of the thoracic aorta with collagen-impregnated woven Dacron grafts. Early results.

Authors:  S Westaby; A Parry; N Giannopoulos; R Pillai
Journal:  J Thorac Cardiovasc Surg       Date:  1993-09       Impact factor: 5.209

7.  Usefulness of antegrade selective cerebral perfusion during aortic arch operations.

Authors:  Teruhisa Kazui; Katsushi Yamashita; Naoki Washiyama; Hitoshi Terada; Abul Hasan Muhammad Bashar; Takayasu Suzuki; Kazuhiro Ohkura
Journal:  Ann Thorac Surg       Date:  2002-11       Impact factor: 4.330

  7 in total
  3 in total

1.  Numerical analysis of blood flow distribution in 4- and 3-branch vascular grafts.

Authors:  Chikako Konoura; Takanobu Yagi; Masanori Nakamura; Kiyotaka Iwasaki; Yi Qian; Shigeo Okuda; Akihiro Yoshitake; Hideyuki Shimizu; Ryohei Yozu; Mitsuo Umezu
Journal:  J Artif Organs       Date:  2013-02-24       Impact factor: 1.731

Review 2.  Journal of Artificial Organs 2012: the year in review.

Authors:  Y Sawa; E Tatsumi; T Tsukiya; K Matsuda; K Fukunaga; A Kishida; T Masuzawa; G Matsumiya; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2013-02-28       Impact factor: 1.731

3.  Does Triplex Vascular Prosthesis Contribute to Reducing the Inflammatory Reaction after Surgical Repair of Abdominal Aortic Aneurysms?

Authors:  Naoto Fukunaga; Takehiko Matsuo; Tadaaki Koyama
Journal:  Ann Vasc Dis       Date:  2016-04-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.