Literature DB >> 21353023

New uncoated vascular prosthesis reduces mediastinal tube drainage after thoracic aortic surgery.

Minoru Tabata1, Tomoki Shimokawa, Toshihiro Fukui, Susumu Manabe, Yasunori Sato, Shuichiro Takanashi.   

Abstract

PURPOSE: A new vascular graft (Triplex [Vascutek Terumo, Tokyo, Japan]) has a three-layer structure and no biologic coating material. We assessed inflammatory reaction and mediastinal tube drainage after thoracic aortic surgery using this graft. DESCRIPTION: Between January 2009 and September 2009, 127 patients underwent open ascending aortic or arch repair. Triplex grafts (Vascutek Terumo) were used in 39 patients. After matching surgical procedures, 35 matched pairs (35 with Triplex, group A; 35 with coated graft, group B) were created. We compared postoperative inflammatory markers, amount, and duration of mediastinal drainage between the two groups. EVALUATION: There was no difference in postoperative inflammatory marker levels between the two groups. The median total amounts of mediastinal drainage were 690 mL (group A) and 1,500 mL (group B) (p < 0.001). The median durations of drainage were 67 and 128 hours, respectively (p < 0.001). Multivariate linear regression analyses showed that use of the Triplex graft is an independent predictor of the small amount and short duration of mediastinal drainage.
CONCLUSIONS: Triplex grafts reduce the amount and duration of mediastinal drainage after thoracic aortic surgery, which may promote early ambulation and fast postoperative recovery.
Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21353023     DOI: 10.1016/j.athoracsur.2010.11.030

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  7 in total

1.  Successful treatment of an infected new vascular graft.

Authors:  Susumu Ishikawa; Yasushi Katayama; Hideki Mishima; Kenji Ohnishi
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-10-07

2.  Development and physical characteristics of novel zero-porosity vascular graft "triplex(®)".

Authors:  Tetsuro Morota; Shinichi Takamoto
Journal:  Ann Vasc Dis       Date:  2013-02-28

3.  Terumo-Triplex grafts for total arch replacement: analysis of postoperative graft performance.

Authors:  Toshihiro Ohata; Hideki Ueda; Kazuya Kobayashi; Hirotsugu Fukuda; Yuji Miyamoto
Journal:  J Artif Organs       Date:  2012-04-21       Impact factor: 1.731

4.  Does Triplex Vascular Prosthesis Contribute to Reducing the Inflammatory Reaction after Surgical Repair of Abdominal Aortic Aneurysms?

Authors:  Naoto Fukunaga; Takehiko Matsuo; Tadaaki Koyama
Journal:  Ann Vasc Dis       Date:  2016-04-06

5.  Prosthetic Graft Dilation at the Aortic Arch in the Era of Hybrid Aortic Surgery.

Authors:  Daijiro Hori; Sho Kusadokoro; Toshikazu Shimizu; Naoyuki Kimura; Atsushi Yamaguchi
Journal:  Ann Vasc Dis       Date:  2020-06-25

6.  Efficacy of non-obstructive aortic angioscopy for detecting a thoracic aortic graft rupture: a case report.

Authors:  Fumio Yamana; Koichi Maeda; Yuma Hamanaka; Noriko Kodani; Keitaro Domae; Masatoshi Hata; Yoshiharu Higuchi; Yukitoshi Shirakawa; Takafumi Masai
Journal:  Surg Case Rep       Date:  2022-03-14

7.  The in vitro research of bacterial invasion of prosthetic vascular grafts: comparison of elastomer-sealed and gelatin-coated Dacron vascular grafts.

Authors:  Yuki Sasaki
Journal:  Surg Today       Date:  2013-10-20       Impact factor: 2.549

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.