Literature DB >> 21339341

Clinical experience with a new vascular graft free from biodegradable material.

Atsushi Tamura1, Atsushi Yamaguchi, Kouichi Yuri, Kenichiro Noguchi, Kazuhiro Naito, Hiroshi Nagano, Masaya Takahashi, Hideo Adachi.   

Abstract

Triplex (Terumo Co., Tokyo, Japan), a newly developed large diameter vascular graft sealed with a non-biodegradable material, is expected to reduce inflammatory reaction. We confirmed its safe implantation and assessed inflammatory reaction after thoracic aortic surgery. Between January 2009 and February 2010, 101 consecutive patients underwent thoracic aortic replacement. Triplex grafts were implanted in 40 patients, and bovine-collagen coated grafts (Hemashield, Boston Scientific, Boston, MA, USA) were implanted in 61 patients. During the postoperative course, body temperature and laboratory findings including inflammatory markers were examined. The mean operation time and amount of bleeding during operation were equivalent in the two groups. The mean body temperature and C-reactive protein in patients implanted with Triplex were significantly lower than those in patients implanted with Hemashield grafts. The mean white blood cell count tended to be at lower levels in patients implanted with Triplex grafts. No patients in both groups suffered postoperative complications associated with the prosthetic grafts. Triplex was confirmed to be safely applied for thoracic aortic surgery as well as the conventional vascular grafts and to reduce postoperative inflammatory reaction.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21339341     DOI: 10.1510/icvts.2010.262022

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  5 in total

1.  Development and physical characteristics of novel zero-porosity vascular graft "triplex(®)".

Authors:  Tetsuro Morota; Shinichi Takamoto
Journal:  Ann Vasc Dis       Date:  2013-02-28

2.  Terumo-Triplex grafts for total arch replacement: analysis of postoperative graft performance.

Authors:  Toshihiro Ohata; Hideki Ueda; Kazuya Kobayashi; Hirotsugu Fukuda; Yuji Miyamoto
Journal:  J Artif Organs       Date:  2012-04-21       Impact factor: 1.731

3.  Prosthetic Graft Dilation at the Aortic Arch in the Era of Hybrid Aortic Surgery.

Authors:  Daijiro Hori; Sho Kusadokoro; Toshikazu Shimizu; Naoyuki Kimura; Atsushi Yamaguchi
Journal:  Ann Vasc Dis       Date:  2020-06-25

4.  The in vitro research of bacterial invasion of prosthetic vascular grafts: comparison of elastomer-sealed and gelatin-coated Dacron vascular grafts.

Authors:  Yuki Sasaki
Journal:  Surg Today       Date:  2013-10-20       Impact factor: 2.549

5.  Stepwise external wrapping procedure for Stanford type A aortic dissection in extremely high-risk patients: case reports.

Authors:  Yoshihiro Suematsu; Satoshi Nishi; Daisuke Arima; Akihiro Yoshimoto
Journal:  J Cardiothorac Surg       Date:  2020-06-12       Impact factor: 1.637

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.