Literature DB >> 18201291

Coated prostheses are associated with prolonged inflammation in aortic surgery: a cost analysis.

Shunya Shindo1, Shinya Motohashi, Masatake Katsu, Shigeaki Kaga, Hidenori Inoue, Masahiko Matsumoto.   

Abstract

This prospective study was conducted to compare inflammatory responses between patients receiving coated and uncoated vascular prostheses, and to examine their effect on length of stay and cost of patients undergoing abdominal aortic aneurysmectomy. Patients undergoing elective vascular reconstruction of an abdominal aortic aneurysm were assigned randomly to coated-graft or uncoated-graft groups (n = 20, for each group). Interleukin (IL)-6, granulocyte elastase, white blood cell count, C-reactive protein (CRP), and body temperature (BT) were prospectively recorded preoperatively and on postoperative days (PODs) 1, 3, 7, and 14. In-hospital stay and hospitalized costs were also analyzed. IL-6 and CRP concentrations in the coated-graft group were higher than those in the uncoated-graft group (P = 0.01 and 0.05). BT was more frequently elevated >37 degrees C at POD 14 in the coated-graft group than in the uncoated-graft group (P =0.03). Discharge was delayed, and overall hospitalization cost was higher in the coated-graft group than in the uncoated group (17.6 vs. 13.5 days, and 2 010 000 vs. 1 780 000 yen, P = 0.006 and P = 0.002, respectively). Coated vascular prosthesis demonstrated more profound inflammatory reaction than noncoated prosthesis, postoperatively.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18201291     DOI: 10.1111/j.1525-1594.2007.00521.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  4 in total

Review 1.  Cardiovascular Bio-Engineering: Current State of the Art.

Authors:  Teresa Simon-Yarza; Isabelle Bataille; Didier Letourneur
Journal:  J Cardiovasc Transl Res       Date:  2017-03-06       Impact factor: 4.132

2.  Terumo-Triplex grafts for total arch replacement: analysis of postoperative graft performance.

Authors:  Toshihiro Ohata; Hideki Ueda; Kazuya Kobayashi; Hirotsugu Fukuda; Yuji Miyamoto
Journal:  J Artif Organs       Date:  2012-04-21       Impact factor: 1.731

3.  Does Triplex Vascular Prosthesis Contribute to Reducing the Inflammatory Reaction after Surgical Repair of Abdominal Aortic Aneurysms?

Authors:  Naoto Fukunaga; Takehiko Matsuo; Tadaaki Koyama
Journal:  Ann Vasc Dis       Date:  2016-04-06

4.  Electrospun polycaprolactone/collagen nanofibers cross-linked with 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide and genipin facilitate endothelial cell regeneration and may be a promising candidate for vascular scaffolds.

Authors:  Dian Chen; Tonghe Zhu; Wei Fu; Haibo Zhang
Journal:  Int J Nanomedicine       Date:  2019-03-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.