Invasive breast cancer: relationship between shear-wave elastographic findings and histologic prognostic factors.

Andrew Evans1, Patsy Whelehan, Kim Thomson, Denis McLean, Katrin Brauer, Colin Purdie, Lee Baker, Lee Jordan, Petra Rauchhaus, Alastair Thompson.   

Abstract

PURPOSE: To compare the histologic prognostic feature of invasive breast cancer with mean stiffness as measured with shear-wave elastography.
MATERIALS AND METHODS: This retrospective study was exempted from ethical committee review. Patient consent for use of images for research was obtained. The study group comprised 101 consecutive women (age range, 38-91 years) with solid lesions identified during routine breast ultrasonography (US) performed between April 2010 and March 2011 and subsequently confirmed at histologic examination to be invasive cancers. Four elastographic images in two orthogonal planes were obtained of each lesion, and mean stiffness values were obtained from each image. Histologic findings following surgery were used for comparison, namely histologic grade, tumor type, invasive size, vascular invasion status, and lymph node status. Relationship between mean stiffness and histologic parameters was investigated by using a general linear model and multiple regression analysis.
RESULTS: High histologic grade (P < .0001), large invasive size (P < .0001), lymph node involvement (P < .0001), tumor type (P < .0001), and vascular invasion (P = .0077) all showed statistically significant positive association with high mean stiffness values. Multiple linear regression indicated that invasive size is the strongest pathologic determinant of mean stiffness (P < .0001), with histologic grade also having significant influence (P = .022).
CONCLUSION: In this study, breast cancers with higher mean stiffness values at shear-wave elastography had poorer prognostic features.

Entities:  

Mesh:

Year:  2012        PMID: 22523322     DOI: 10.1148/radiol.12111317

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  75 in total

1.  A novel two-dimensional quantitative shear wave elastography for differentiating malignant from benign breast lesions.

Authors:  Li Tang; Hui-Xiong Xu; Xiao-Wan Bo; Bo-Ji Liu; Xiao-Long Li; Rong Wu; Dan-Dan Li; Lin Fang; Xiao-Hong Xu
Journal:  Int J Clin Exp Med       Date:  2015-07-15

2.  Diagnostic value of virtual touch tissue imaging quantification for benign and malignant breast lesions with different sizes.

Authors:  Hui Liu; Li-Xia Zhao; Guang Xu; Ming-Hua Yao; Ai-Hong Zhang; Hui-Xiong Xu; Rong Wu
Journal:  Int J Clin Exp Med       Date:  2015-08-15

3.  Potential role of shear-wave ultrasound elastography for the differential diagnosis of breast non-mass lesions: preliminary report.

Authors:  Kyung Hee Ko; Hae Kyoung Jung; So Joong Kim; Hyerin Kim; Jung Hyun Yoon
Journal:  Eur Radiol       Date:  2013-10-02       Impact factor: 5.315

4.  Shear wave elastography in the diagnosis of breast non-mass lesions: factors associated with false negative and false positive results.

Authors:  So Yoon Park; Ji Soo Choi; Boo-Kyung Han; Eun Young Ko; Eun Sook Ko
Journal:  Eur Radiol       Date:  2017-02-06       Impact factor: 5.315

5.  Differentiation of benign from malignant solid breast masses: comparison of two-dimensional and three-dimensional shear-wave elastography.

Authors:  Su Hyun Lee; Jung Min Chang; Won Hwa Kim; Min Sun Bae; Nariya Cho; Ann Yi; Hye Ryoung Koo; Seung Ja Kim; Jin You Kim; Woo Kyung Moon
Journal:  Eur Radiol       Date:  2012-10-20       Impact factor: 5.315

6.  What are the characteristics of breast cancers misclassified as benign by quantitative ultrasound shear wave elastography?

Authors:  S J Vinnicombe; P Whelehan; K Thomson; D McLean; C A Purdie; L B Jordan; S Hubbard; A J Evans
Journal:  Eur Radiol       Date:  2013-12-11       Impact factor: 5.315

7.  Tissue mimicking materials for the detection of prostate cancer using shear wave elastography: a validation study.

Authors:  Rui Cao; Zhihong Huang; Tomy Varghese; Ghulam Nabi
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

8.  Tumor stiffness measured by quantitative and qualitative shear wave elastography of breast cancer.

Authors:  Eun Jee Song; Yu-Mee Sohn; Mirinae Seo
Journal:  Br J Radiol       Date:  2018-04-09       Impact factor: 3.039

9.  Sonographic and sonoelastographic findings of a rarely seen soft tissue tumor: eccrine spiradenoma.

Authors:  Mehtap Balaban; Ilkay S Idilman; Ozlem Unal; Ersin Gurkan Dumlu; Aylin Yazgan; Ali Ipek
Journal:  J Med Ultrason (2001)       Date:  2015-05-23       Impact factor: 1.314

10.  Transrectal quantitative shear wave elastography in the detection and characterisation of prostate cancer.

Authors:  Sarfraz Ahmad; Rui Cao; Tomy Varghese; Luc Bidaut; Ghulam Nabi
Journal:  Surg Endosc       Date:  2013-03-23       Impact factor: 4.584