Literature DB >> 22505568

MRI-based attenuation correction for hybrid PET/MRI systems: a 4-class tissue segmentation technique using a combined ultrashort-echo-time/Dixon MRI sequence.

Yannick Berker1, Jochen Franke, André Salomon, Moritz Palmowski, Henk C W Donker, Yavuz Temur, Felix M Mottaghy, Christiane Kuhl, David Izquierdo-Garcia, Zahi A Fayad, Fabian Kiessling, Volkmar Schulz.   

Abstract

UNLABELLED: Accurate γ-photon attenuation correction (AC) is essential for quantitative PET/MRI as there is no simple relation between MR image intensity and attenuation coefficients. Attenuation maps (μ-maps) can be derived by segmenting MR images and assigning attenuation coefficients to the compartments. Ultrashort-echo-time (UTE) sequences have been used to separate cortical bone and air, and the Dixon technique has enabled differentiation between soft and adipose tissues. Unfortunately, sequential application of these sequences is time-consuming and complicates image registration.
METHODS: A UTE triple-echo (UTILE) MRI sequence is proposed, combining UTE sampling for bone detection and gradient echoes for Dixon water-fat separation in a radial 3-dimensional acquisition (repetition time, 4.1 ms; echo times, 0.09/1.09/2.09 ms; field strength, 3 T). Air masks are derived mainly from the phase information of the first echo; cortical bone is segmented using a dual-echo technique. Soft-tissue and adipose-tissue decomposition is achieved using a 3-point Dixon-like decomposition. Predefined linear attenuation coefficients are assigned to classified voxels to generate MRI-based μ-maps. The results of 6 patients are obtained by comparing μ-maps, reciprocal sensitivity maps, reconstructed PET images, and brain region PET activities based on either CT AC, two 3-class MRI AC techniques, or the proposed 4-class UTILE AC.
RESULTS: Using the UTILE MRI sequence, an acquisition time of 214 s was achieved for the head-and-neck region with 1.75-mm isotropic resolution, compared with 164 s for a single-echo UTE scan. MRI-based reciprocal sensitivity maps show a high correlation with those derived from CT scans (R(2) = 0.9920). The same is true for PET activities (R(2) = 0.9958). An overall voxel classification accuracy (compared with CT) of 81.1% was reached. Bone segmentation is inaccurate in complex regions such as the paranasal sinuses, but brain region activities in 48 regions across 6 patients show a high correlation after MRI-based and CT-based correction (R(2) = 0.9956), with a regression line slope of 0.960. All overall correlations are higher and brain region PET activities more accurate in terms of mean and maximum deviations for the 4-class technique than for 3-class techniques.
CONCLUSION: The UTILE MRI sequence enables the generation of MRI-based 4-class μ-maps without anatomic priors, yielding results more similar to CT-based results than can be obtained with 3-class segmentation only.

Entities:  

Mesh:

Year:  2012        PMID: 22505568     DOI: 10.2967/jnumed.111.092577

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  113 in total

1.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Multiscale segmentation of the skull in MR images for MRI-based attenuation correction of combined MR/PET.

Authors:  Xiaofeng Yang; Baowei Fei
Journal:  J Am Med Inform Assoc       Date:  2013-06-12       Impact factor: 4.497

3.  Investigation of a method for generating synthetic CT models from MRI scans of the head and neck for radiation therapy.

Authors:  Shu-Hui Hsu; Yue Cao; Ke Huang; Mary Feng; James M Balter
Journal:  Phys Med Biol       Date:  2013-11-11       Impact factor: 3.609

4.  Improvement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.

Authors:  Pieter Mollet; Vincent Keereman; Jason Bini; David Izquierdo-Garcia; Zahi A Fayad; Stefaan Vandenberghe
Journal:  J Nucl Med       Date:  2014-01-16       Impact factor: 10.057

5.  Accurate PET/MR quantification using time of flight MLAA image reconstruction.

Authors:  R Boellaard; M B M Hofman; O S Hoekstra; A A Lammertsma
Journal:  Mol Imaging Biol       Date:  2014-08       Impact factor: 3.488

Review 6.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

7.  On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners.

Authors:  Kevin T Chen; David Izquierdo-Garcia; Clare B Poynton; Daniel B Chonde; Ciprian Catana
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-29       Impact factor: 9.236

Review 8.  PET and MR imaging: the odd couple or a match made in heaven?

Authors:  Ciprian Catana; Alexander R Guimaraes; Bruce R Rosen
Journal:  J Nucl Med       Date:  2013-03-14       Impact factor: 10.057

Review 9.  MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

Authors:  David Izquierdo-Garcia; Ciprian Catana
Journal:  PET Clin       Date:  2016-01-26

10.  Evaluation of attenuation correction in cardiac PET using PET/MR.

Authors:  Jeffrey M C Lau; R Laforest; H Sotoudeh; X Nie; S Sharma; J McConathy; E Novak; A Priatna; R J Gropler; P K Woodard
Journal:  J Nucl Cardiol       Date:  2015-10-23       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.