Literature DB >> 22505325

A new method for detecting exchanging amide protons using chemical exchange rotation transfer.

Zhongliang Zu1, Vaibhav A Janve, Junzhong Xu, Mark D Does, John C Gore, Daniel F Gochberg.   

Abstract

In this study, we introduce a new method for amide proton transfer imaging based on chemical exchange rotation transfer. It avoids several artifacts that plague conventional chemical exchange saturation transfer approaches by creating label and reference scans based on varying the irradiation pulse rotation angle (π and 2π radians) instead of the frequency offset (3.5 and -3.5 ppm). Specifically, conventional analysis is sensitive to confounding contributions from magnetic field (B(0)) inhomogeneities and, more problematically, inherently asymmetric macromolecular resonances. In addition, the lipid resonance at -3.5 ppm complicates the interpretation of the reference scan and decreases the resulting contrast. Finally, partial overlap of the amide signal by nearby amines and hydroxyls obscure the results. By avoiding these issues, our new method is a promising approach for imaging endogenous protein and peptide content and mapping pH.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22505325      PMCID: PMC3625661          DOI: 10.1002/mrm.24284

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  43 in total

1.  Z-spectroscopy with Alternating-Phase Irradiation.

Authors:  Johanna Närväinen; Penny L Hubbard; Risto A Kauppinen; Gareth A Morris
Journal:  J Magn Reson       Date:  2010-09-15       Impact factor: 2.229

2.  Early experience of translating pH-weighted MRI to image human subjects at 3 Tesla.

Authors:  Phillip Zhe Sun; Thomas Benner; William A Copen; A Gregory Sorensen
Journal:  Stroke       Date:  2010-10       Impact factor: 7.914

3.  Magnetization transfer magic-angle-spinning z-spectroscopy of excised tissues.

Authors:  Reut Avni; Oren Mangoubi; Rangeet Bhattacharyya; Hadassa Degani; Lucio Frydman
Journal:  J Magn Reson       Date:  2009-03-24       Impact factor: 2.229

4.  Methods for an improved detection of the MRI-CEST effect.

Authors:  Enzo Terreno; Joseph Stancanello; Dario Longo; Daniela Delli Castelli; Luciano Milone; Honorius M H F Sanders; Maarten B Kok; Fulvio Uggeri; Silvio Aime
Journal:  Contrast Media Mol Imaging       Date:  2009 Sep-Oct       Impact factor: 3.161

5.  Origins of the ultrashort-T2 1H NMR signals in myelinated nerve: a direct measure of myelin content?

Authors:  R Adam Horch; John C Gore; Mark D Does
Journal:  Magn Reson Med       Date:  2011-05-13       Impact factor: 4.668

6.  Simplified and scalable numerical solution for describing multi-pool chemical exchange saturation transfer (CEST) MRI contrast.

Authors:  Phillip Zhe Sun
Journal:  J Magn Reson       Date:  2010-05-10       Impact factor: 2.229

7.  A concentration-independent method to measure exchange rates in PARACEST agents.

Authors:  W Thomas Dixon; Jimin Ren; Angelo J M Lubag; James Ratnakar; Elena Vinogradov; Ileana Hancu; Robert E Lenkinski; A Dean Sherry
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

8.  Chemical exchange saturation transfer (CEST): what is in a name and what isn't?

Authors:  Peter C M van Zijl; Nirbhay N Yadav
Journal:  Magn Reson Med       Date:  2011-02-17       Impact factor: 4.668

9.  Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain.

Authors:  He Zhu; Craig K Jones; Peter C M van Zijl; Peter B Barker; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

10.  Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments.

Authors:  Mina Kim; Joseph Gillen; Bennett A Landman; Jinyuan Zhou; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

View more
  53 in total

1.  Free-base porphyrins as CEST MRI contrast agents with highly upfield shifted labile protons.

Authors:  Xiaoxiao Zhang; Yaping Yuan; Sha Li; Qingbin Zeng; Qianni Guo; Na Liu; Minghui Yang; Yunhuang Yang; Maili Liu; Michael T McMahon; Xin Zhou
Journal:  Magn Reson Med       Date:  2019-04-10       Impact factor: 4.668

2.  Predicting IDH mutation status in grade II gliomas using amide proton transfer-weighted (APTw) MRI.

Authors:  Shanshan Jiang; Tianyu Zou; Charles G Eberhart; Maria A V Villalobos; Hye-Young Heo; Yi Zhang; Yu Wang; Xianlong Wang; Hao Yu; Yongxing Du; Peter C M van Zijl; Zhibo Wen; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2017-07-16       Impact factor: 4.668

3.  Inverse Z-spectrum analysis for spillover-, MT-, and T1 -corrected steady-state pulsed CEST-MRI--application to pH-weighted MRI of acute stroke.

Authors:  Moritz Zaiss; Junzhong Xu; Steffen Goerke; Imad S Khan; Robert J Singer; John C Gore; Daniel F Gochberg; Peter Bachert
Journal:  NMR Biomed       Date:  2014-01-03       Impact factor: 4.044

4.  Contributors to contrast between glioma and brain tissue in chemical exchange saturation transfer sensitive imaging at 3 Tesla.

Authors:  Rachel Scheidegger; Eric T Wong; David C Alsop
Journal:  Neuroimage       Date:  2014-05-20       Impact factor: 6.556

5.  Simultaneous pH-sensitive and oxygen-sensitive MRI of human gliomas at 3 T using multi-echo amine proton chemical exchange saturation transfer spin-and-gradient echo echo-planar imaging (CEST-SAGE-EPI).

Authors:  Robert J Harris; Jingwen Yao; Ararat Chakhoyan; Catalina Raymond; Kevin Leu; Linda M Liau; Phioanh L Nghiemphu; Albert Lai; Noriko Salamon; Whitney B Pope; Timothy F Cloughesy; Benjamin M Ellingson
Journal:  Magn Reson Med       Date:  2018-04-06       Impact factor: 4.668

Review 6.  A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging.

Authors:  Jinsuh Kim; Yin Wu; Yingkun Guo; Hairong Zheng; Phillip Zhe Sun
Journal:  Contrast Media Mol Imaging       Date:  2015-01-12       Impact factor: 3.161

7.  Separating fast and slow exchange transfer and magnetization transfer using off-resonance variable-delay multiple-pulse (VDMP) MRI.

Authors:  Lin Chen; Xiang Xu; Haifeng Zeng; Kannie W Y Chan; Nirbhay Yadav; Shuhui Cai; Kathryn J Schunke; Nauder Faraday; Peter C M van Zijl; Jiadi Xu
Journal:  Magn Reson Med       Date:  2018-02-05       Impact factor: 4.668

8.  Chemical exchange rotation transfer (CERT) on human brain at 3 Tesla.

Authors:  Eugene C Lin; Hua Li; Zhongliang Zu; Elizabeth A Louie; Christopher L Lankford; Richard D Dortch; Mark D Does; John C Gore; Daniel F Gochberg
Journal:  Magn Reson Med       Date:  2018-05-25       Impact factor: 4.668

Review 9.  Magnetization Transfer Contrast and Chemical Exchange Saturation Transfer MRI. Features and analysis of the field-dependent saturation spectrum.

Authors:  Peter C M van Zijl; Wilfred W Lam; Jiadi Xu; Linda Knutsson; Greg J Stanisz
Journal:  Neuroimage       Date:  2017-04-21       Impact factor: 6.556

10.  Relayed nuclear Overhauser enhancement sensitivity to membrane Cho phospholipids.

Authors:  Zhongliang Zu; Eugene C Lin; Elizabeth A Louie; Junzhong Xu; Hua Li; Jingping Xie; Christopher L Lankford; Eduard Y Chekmenev; Scott D Swanson; Mark D Does; John C Gore; Daniel F Gochberg
Journal:  Magn Reson Med       Date:  2020-04-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.