Literature DB >> 19839029

Methods for an improved detection of the MRI-CEST effect.

Enzo Terreno1, Joseph Stancanello, Dario Longo, Daniela Delli Castelli, Luciano Milone, Honorius M H F Sanders, Maarten B Kok, Fulvio Uggeri, Silvio Aime.   

Abstract

CEST imaging is a recently introduced MRI contrast modality based on the use of endogenous or exogenous molecules whose exchangeable proton pools transfer saturated magnetization to bulk water, thus creating negative contrast. One of the critical issues for further development of these agents is represented by their limited sensitivity in vivo. The aim of this work is to improve the detection of CEST agents by exploring new approaches through which the saturation transfer (ST) effect can be enhanced. The performance of the proposed methods has been tested in vitro and in vivo using highly sensitive and highly shifted lipoCEST agents, and the results were compared with the standard ST evaluation mode. The acquired Z-spectra were interpolated locally and voxel-by-voxel by smoothing splines. Besides expressing the ST in the standard mode, we explore two methods, enhanced and integral ST, which better exploit all the information contained in the Z-spectrum. By combining different modes for ST assessment a significant improvement in the detection of the lipoCEST agents, both in vitro and in vivo, has been found. The results obtained from the application of the proposed methods outline the importance of post-processing analysis for highlighting the CEST-MRI contrast.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19839029     DOI: 10.1002/cmmi.290

Source DB:  PubMed          Journal:  Contrast Media Mol Imaging        ISSN: 1555-4309            Impact factor:   3.161


  28 in total

1.  Noninvasive imaging of infection after treatment with tumor-homing bacteria using Chemical Exchange Saturation Transfer (CEST) MRI.

Authors:  Guanshu Liu; Chetan Bettegowda; Yuan Qiao; Verena Staedtke; Kannie W Y Chan; Renyuan Bai; Yuguo Li; Gregory J Riggins; Kenneth W Kinzler; Jeff W M Bulte; Michael T McMahon; Assaf A Gilad; Bert Vogelstein; Shibin Zhou; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

Review 2.  Rational chemical design of the next generation of molecular imaging probes based on physics and biology: mixing modalities, colors and signals.

Authors:  Hisataka Kobayashi; Michelle R Longmire; Mikako Ogawa; Peter L Choyke
Journal:  Chem Soc Rev       Date:  2011-05-23       Impact factor: 54.564

3.  MRI-CEST assessment of tumour perfusion using X-ray iodinated agents: comparison with a conventional Gd-based agent.

Authors:  Annasofia Anemone; Lorena Consolino; Dario Livio Longo
Journal:  Eur Radiol       Date:  2016-08-29       Impact factor: 5.315

4.  CEST phase mapping using a length and offset varied saturation (LOVARS) scheme.

Authors:  Xiaolei Song; Assaf A Gilad; Suresh Joel; Guanshu Liu; Amnon Bar-Shir; Yajie Liang; Michael Gorelik; James J Pekar; Peter C M van Zijl; Jeff W M Bulte; Michael T McMahon
Journal:  Magn Reson Med       Date:  2012-01-13       Impact factor: 4.668

5.  Improved pH measurements with a single PARACEST MRI contrast agent.

Authors:  Vipul R Sheth; Guanshu Liu; Yuguo Li; Mark D Pagel
Journal:  Contrast Media Mol Imaging       Date:  2012 Jan-Feb       Impact factor: 3.161

6.  Responsive paramagnetic chemical exchange saturation transfer MRI contrast agents.

Authors:  Mark D Pagel
Journal:  Imaging Med       Date:  2011

7.  A new method for detecting exchanging amide protons using chemical exchange rotation transfer.

Authors:  Zhongliang Zu; Vaibhav A Janve; Junzhong Xu; Mark D Does; John C Gore; Daniel F Gochberg
Journal:  Magn Reson Med       Date:  2012-04-13       Impact factor: 4.668

8.  Insight into the quantitative metrics of chemical exchange saturation transfer (CEST) imaging.

Authors:  Hye-Young Heo; Dong-Hoon Lee; Yi Zhang; Xuna Zhao; Shanshan Jiang; Min Chen; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2016-05-12       Impact factor: 4.668

Review 9.  Polymeric micelles in anticancer therapy: targeting, imaging and triggered release.

Authors:  Chris Oerlemans; Wouter Bult; Mariska Bos; Gert Storm; J Frank W Nijsen; Wim E Hennink
Journal:  Pharm Res       Date:  2010-08-20       Impact factor: 4.200

Review 10.  Application of chemical exchange saturation transfer (CEST) MRI for endogenous contrast at 7 Tesla.

Authors:  Adrienne N Dula; Seth A Smith; John C Gore
Journal:  J Neuroimaging       Date:  2013-02-12       Impact factor: 2.486

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.