Saurabh Singh 1 , Rishabh Surana 1 , Alok Rai 1 , Divyansh Sharma 1 . Show Affiliations »
Abstract
BACKGROUND: Tension band wiring supposedly is the most commonly used technique for displaced patella fractures, but is not effective in comminuted fractures and osteoporotic bones. It often leads to loosening of wires, dislocation of fracture, hardware problem and failure of osteosynthesis, resulting in knee stiffness and post-traumatic osteoarthritis. The aim of the study is to evaluate clinical outcome in patients with acute patella fractures (< 3 week) treated with unidirectional angle fixed low-profile titanium patella locking plate. MATERIALS AND METHODS: Twenty patients who presented with displaced patella fractures, aged between 18-70 years were included in the study. All fractures were reduced and fixed with unidirectional angle fixed stable low-profile titanium patella locking plate. Knee Range of motion and Knee Outcome Survey Activities of Daily Living Scale (KOS-ADL) was used to evaluate the outcome. RESULTS: We were able to achieve union in 19 out of 20 patients. One patient with comminuted patella fracture had failure of fixation, which was revised. Mean flexion at final follow-up was 124° (110°-130°) and none of the patients had extensor lag. The final radiograph revealed complete union in all patients. CONCLUSION: This technique offers an option of fixation in comminuted patella fracture and in osteoporotic individuals. It provides mechanical stability for fracture fixation resulting in anatomical reduction, good functional outcome, lower incidence of symptomatic implant or failure of osteosynthesis. © Indian Orthopaedics Association 2020.
BACKGROUND: Tension band wiring supposedly is the most commonly used technique for displaced patella fractures, but is not effective in comminuted fractures and osteoporotic bones. It often leads to loosening of wires, dislocation of fracture, hardware problem and failure of osteosynthesis, resulting in knee stiffness and post-traumatic osteoarthritis. The aim of the study is to evaluate clinical outcome in patients with acute patella fractures (< 3 week) treated with unidirectional angle fixed low-profile titanium patella locking plate. MATERIALS AND METHODS: Twenty patients who presented with displaced patella fractures, aged between 18-70 years were included in the study. All fractures were reduced and fixed with unidirectional angle fixed stable low-profile titanium patella locking plate. Knee Range of motion and Knee Outcome Survey Activities of Daily Living Scale (KOS-ADL) was used to evaluate the outcome. RESULTS: We were able to achieve union in 19 out of 20 patients. One patient with comminuted patella fracture had failure of fixation, which was revised. Mean flexion at final follow-up was 124° (110°-130°) and none of the patients had extensor lag. The final radiograph revealed complete union in all patients. CONCLUSION: This technique offers an option of fixation in comminuted patella fracture and in osteoporotic individuals. It provides mechanical stability for fracture fixation resulting in anatomical reduction, good functional outcome, lower incidence of symptomatic implant or failure of osteosynthesis. © Indian Orthopaedics Association 2020.
Entities: Chemical
Keywords:
Comminuted; Locking plate; Osteoporotic; Osteosynthesis; Patella fracture
Year: 2020
PMID: 33995869 PMCID: PMC8081821 DOI: 10.1007/s43465-020-00302-4
Source DB: PubMed Journal: Indian J Orthop ISSN: 0019-5413 Impact factor: 1.251