Literature DB >> 22489022

Reduced field-of-view excitation using second-order gradients and spatial-spectral radiofrequency pulses.

Chao Ma1, Dan Xu, Kevin F King, Zhi-Pei Liang.   

Abstract

The performance of multidimensional spatially selective radiofrequency (RF) pulses is often limited by their long duration. In this article, high-order, nonlinear gradients are exploited to reduce multidimensional RF pulse length. Specifically, by leveraging the multidimensional spatial dependence of second-order gradients, a two-dimensional spatial-spectral RF pulse is designed to achieve three-dimensional spatial selectivity, i.e., to excite a circular region-of-interest in a thin slice for reduced field-of-view imaging. Compared to conventional methods that use three-dimensional RF pulses and linear gradients, the proposed method requires only two-dimensional RF pulses, and thus can significantly shorten the RF pulses and/or improve excitation accuracy. The proposed method has been validated through Bloch equation simulations and phantom experiments on a commercial 3.0T MRI scanner.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22489022      PMCID: PMC3406253          DOI: 10.1002/mrm.24259

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  MRI geometric distortion: a simple approach to correcting the effects of non-linear gradient fields.

Authors:  S Langlois; M Desvignes; J M Constans; M Revenu
Journal:  J Magn Reson Imaging       Date:  1999-06       Impact factor: 4.813

2.  Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities.

Authors:  Bradley P Sutton; Douglas C Noll; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2003-02       Impact factor: 10.048

3.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

4.  New spatial localization method using pulsed high-order field gradients (SHOT: Selection with High-Order gradienT).

Authors:  C H Oh; S K Hilal; Z H Cho; I K Mun
Journal:  Magn Reson Med       Date:  1991-03       Impact factor: 4.668

5.  A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities.

Authors:  H Chang; J M Fitzpatrick
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

6.  Simultaneous spatial and spectral selective excitation.

Authors:  C H Meyer; J M Pauly; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1990-08       Impact factor: 4.668

7.  Fast slice-selective radio-frequency excitation pulses for mitigating B+1 inhomogeneity in the human brain at 7 Tesla.

Authors:  Adam C Zelinski; Lawrence L Wald; Kawin Setsompop; Vijayanand Alagappan; Borjan A Gagoski; Vivek K Goyal; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

8.  Joint design of spoke trajectories and RF pulses for parallel excitation.

Authors:  Chao Ma; Dan Xu; Kevin F King; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2010-11-05       Impact factor: 4.668

9.  Magnetic field modeling with a set of individual localized coils.

Authors:  Christoph Juchem; Terence W Nixon; Scott McIntyre; Douglas L Rothman; Robin A de Graaf
Journal:  J Magn Reson       Date:  2010-03-11       Impact factor: 2.229

10.  A new 3D localization technique using quadratic field gradients.

Authors:  E X Wu; G Johnson; S K Hilal; Z H Cho
Journal:  Magn Reson Med       Date:  1994-08       Impact factor: 4.668

View more
  5 in total

1.  Elliptical localization with pulsed second-order fields (ECLIPSE) for robust lipid suppression in proton MRSI.

Authors:  Robin A de Graaf; Peter B Brown; Henk M De Feyter; Scott McIntyre; Terence W Nixon
Journal:  NMR Biomed       Date:  2018-07-09       Impact factor: 4.044

2.  Reduced field of view imaging using a static second-order gradient for functional MRI applications.

Authors:  Haisam Islam; Gary H Glover
Journal:  Magn Reson Med       Date:  2015-03-25       Impact factor: 4.668

Review 3.  Diffusion and quantification of diffusion of prostate cancer.

Authors:  Yoshiko Ueno; Tsutomu Tamada; Keitaro Sofue; Takamichi Murakami
Journal:  Br J Radiol       Date:  2021-09-19       Impact factor: 3.039

4.  Mitigation of B1+ inhomogeneity using spatially selective excitation with jointly designed quadratic spatial encoding magnetic fields and RF shimming.

Authors:  Yi-Cheng Hsu; Riccardo Lattanzi; Ying-Hua Chu; Martijn A Cloos; Daniel K Sodickson; Fa-Hsuan Lin
Journal:  Magn Reson Med       Date:  2016-10-02       Impact factor: 4.668

5.  Radiofrequency pulse design using nonlinear gradient magnetic fields.

Authors:  Emre Kopanoglu; R Todd Constable
Journal:  Magn Reson Med       Date:  2014-09-09       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.