PURPOSE: To determine the agreement between scanning slit topography (Orbscan II, Bausch & Lomb) and Scheimpflug imaging (Pentacam, Oculus) in corneal elevation, corneal curvature, and anterior chamber depth (ACD) measurements before and after laser refractive surgery for myopia and to compare the postoperative changes seen with these devices.
SETTING: Noor Vision Correction Center, Tehran, Iran.
METHODS: In a prospective observational case-series study, 23 consecutive myopic patients having laser refractive surgery were examined with the Orbscan II and Pentacam preoperatively and 6 weeks postoperatively. Readings of ACD, anterior (A-) and posterior (P-) best-fit sphere (BFS) size, central elevation (CE), maximum elevation (ME), axial power in the 3.0 mm zone (AX3) and 5.0 mm zone (AX5), and tangential power in these zones (TG3 and TG5, respectively) were collected and used in the analyses.
RESULTS: Statistically significant interdevice differences were found preoperatively for all parameters except P-TG3 (P = .014) and in operated eyes for ACD, anterior parameters of A-AX3 and A-AX5, and all posterior corneal parameters. In posterior corneal measurements, Orbscan II demonstrated significant postoperative changes in all parameters except P-AX5 (P = .004) and P-TG5 (P = .034), although none of the differences was statistically significant with the Pentacam. The devices measured similar postoperative changes in anterior curvature parameters and in P-AX5 and P-TG5; all other changes were significantly different.
CONCLUSIONS: Compared to the Pentacam, the Orbscan II yielded larger posterior elevation values before and after surgery and significant postoperative changes in P-CE and P-ME. Further studies can determine which device gives more accurate images of the cornea and redefine screening criteria.

Entities:  

Mesh:

Year:  2007        PMID: 17466859     DOI: 10.1016/j.jcrs.2007.01.019

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  19 in total

1.  The change in internal aberrations following myopic corneal laser refractive surgery.

Authors:  Colm McAlinden; Jonathan E Moore
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-07-31       Impact factor: 3.117

2.  Comparison of central corneal thickness measurements by Orbscan II and Pentacam after corneal refractive surgery.

Authors:  Jumpei Matsuda; Osamu Hieda; Shigeru Kinoshita
Journal:  Jpn J Ophthalmol       Date:  2008-09-05       Impact factor: 2.447

3.  Clinical Evaluation and Validation of the Dutch Crosslinking for Keratoconus Score.

Authors:  Robert P L Wisse; Rob W P Simons; Martijn J B van der Vossen; Marc B Muijzer; Nienke Soeters; Rudy M M A Nuijts; Daniel A Godefrooij
Journal:  JAMA Ophthalmol       Date:  2019-06-01       Impact factor: 7.389

Review 4.  Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review.

Authors:  Alberto Domínguez-Vicent; Cari Pérez-Vives; Teresa Ferrer-Blasco; Santiago García-Lázaro; Robert Montés-Micó
Journal:  Int J Ophthalmol       Date:  2016-07-18       Impact factor: 1.779

5.  Scanning-slit topography in patients with keratoconus.

Authors:  László Módis; Gábor Németh; Eszter Szalai; Zsuzsa Flaskó; Berthold Seitz
Journal:  Int J Ophthalmol       Date:  2017-11-18       Impact factor: 1.779

6.  Effects of pterygium surgery on front and back corneal surfaces and anterior segment parameters.

Authors:  Ahmad Kheirkhah; Hamid Safi; Rahman Nazari; Reza Kaghazkanani; Hassan Hashemi; Mahmoud Jabbarvand Behrouz
Journal:  Int Ophthalmol       Date:  2012-04-07       Impact factor: 2.031

7.  Day to Day Clinically Relevant Corneal Elevation, Thickness, and Curvature Parameters Using the Orbscan II Scanning Slit Topographer and the Pentacam Scheimpflug Imaging Device.

Authors:  Hassan Hashemi; Shiva Mehravaran
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

8.  Posterior corneal curvature assessment after Epi-LASIK for myopia: comparison of Orbscan II and Pentacam imaging.

Authors:  Yong-Soo Byun; So-Hyang Chung; Young-Geun Park; Choun-Ki Joo
Journal:  Korean J Ophthalmol       Date:  2012-01-14

9.  No change in anterior chamber dimensions after femtosecond LASIK for hyperopia.

Authors:  Xiaodong Zhou; Tao Li; Zhi Chen; Lingling Niu; Xingtao Zhou; Zimei Zhou
Journal:  Eye Contact Lens       Date:  2015-05       Impact factor: 2.018

10.  Posterior corneal curvature changes following Refractive Small Incision Lenticule Extraction.

Authors:  Sri Ganesh; Utsav Patel; Sheetal Brar
Journal:  Clin Ophthalmol       Date:  2015-07-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.