Agreement between Pentacam and videokeratography in corneal power assessment.

Giacomo Savini1, Piero Barboni, Michele Carbonelli, Kenneth J Hoffer.   

Abstract

PURPOSE: To investigate agreement between a rotating Scheimpflug camera (Pentacam, Oculus Optikgeräte GmbH) and two corneal topographers (TMS-2 Topography System, Tomey; and Keratron Scout, Optikon 2000 SpA) in measuring the corneal power of normal eyes.
METHODS: The mean corneal powers calculated by simulated keratometry (SimK) with each topographer were compared to those provided by the Pentacam in 71 patients. Specifically, the corneal power values of the Pentacam included in this analysis were the SimK (calculated using the measured anterior corneal radius and standard keratometric index of 1.3375) and the True net power (calculated using the anterior and posterior corneal curvatures and Gaussian optics formula for thick lenses, where the actual refractive index of the air, cornea, and aqueous humor are entered). Bland-Altman plots were used to investigate agreement and analysis of variance (ANOVA) was performed to detect statistical differences.
RESULTS: Although ANOVA did not disclose a statistically significant difference among the mean SimK values (TMS-2: 43.20 +/- 1.51 diopters [D], Keratron Scout: 43.29 +/-1.48 D, Pentacam: 43.25 +/- 1.53 D), the 95% limits of agreement between the TMS-2 and Pentacam and between the Keratron Scout and Pentacam were wide (-1.05 to +0.94 D and -0.95 to +1.02 D, respectively). Agreement was even poorer when considering the mean True net power (42.00 +/- 1.54 D), which was significantly lower than the mean Pentacam SimK (P < .001).
CONCLUSIONS: Although corneal topography and the Pentacam provide similar SimK values, their data should not be used interchangeably as only moderate agreement exists between them. Corneal power values calculated by the True net power are significantly lower than any SimK and cannot be entered into intraocular lens power formulas.

Entities:  

Mesh:

Year:  2009        PMID: 19603621     DOI: 10.3928/1081597X-20090512-07

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  18 in total

1.  Assessment of total corneal power after myopic corneal refractive surgery in Chinese eyes.

Authors:  Yanjun Hua; Chao Pan; Qinmei Wang
Journal:  Int Ophthalmol       Date:  2019-03-01       Impact factor: 2.031

2.  OPD-Scan III: a repeatability and inter-device agreement study of a multifunctional device in emmetropia, ametropia, and keratoconus.

Authors:  Soheila Asgari; Hassan Hashemi; Ebrahim Jafarzadehpur; Alireza Mohamadi; Farhad Rezvan; Akbar Fotouhi
Journal:  Int Ophthalmol       Date:  2016-02-08       Impact factor: 2.031

3.  Effects of pterygium surgery on front and back corneal surfaces and anterior segment parameters.

Authors:  Ahmad Kheirkhah; Hamid Safi; Rahman Nazari; Reza Kaghazkanani; Hassan Hashemi; Mahmoud Jabbarvand Behrouz
Journal:  Int Ophthalmol       Date:  2012-04-07       Impact factor: 2.031

4.  Peripheral corneal relaxing incisions based on anterior keratometry from Scheimpflug tomography versus Placido topography during standard cataract surgery.

Authors:  Mayank A Nanavaty; Marizol Dizon; Shruti Malde; Danillo Favor; Damian B Lake
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-12-05       Impact factor: 3.117

5.  Corneal topography with high-speed swept source OCT in clinical examination.

Authors:  Karol Karnowski; Bartlomiej J Kaluzny; Maciej Szkulmowski; Michalina Gora; Maciej Wojtkowski
Journal:  Biomed Opt Express       Date:  2011-08-29       Impact factor: 3.732

6.  Keratometric index obtained by Fourier-domain optical coherence tomography.

Authors:  Yanjun Hua; Aleksander Stojanovic; Tor Paaske Utheim; Xiangjun Chen; Sten Ræder; Jinhai Huang; Qinmei Wang
Journal:  PLoS One       Date:  2015-04-17       Impact factor: 3.240

7.  Comparison of the Corneal Power Measurements with the TMS4-Topographer, Pentacam HR, IOL Master, and Javal Keratometer.

Authors:  Zahra Dehnavi; Mehdi Khabazkhoob; Ali Mirzajani; Mahmood Jabbarvand; Abbasali Yekta; Ebrahim Jafarzadehpur
Journal:  Middle East Afr J Ophthalmol       Date:  2015 Apr-Jun

8.  Precision and agreement of corneal power measurements obtained using a new corneal topographer OphthaTOP.

Authors:  Jinhai Huang; Giacomo Savini; Hao Chen; Fangjun Bao; Yuanguang Li; Haisi Chen; Weicong Lu; Ye Yu; Qinmei Wang
Journal:  PLoS One       Date:  2015-01-05       Impact factor: 3.240

9.  A comprehensive assessment of the precision and agreement of anterior corneal power measurements obtained using 8 different devices.

Authors:  Qinmei Wang; Giacomo Savini; Kenneth J Hoffer; Zhen Xu; Yifan Feng; Daizong Wen; Yanjun Hua; Feng Yang; Chao Pan; Jinhai Huang
Journal:  PLoS One       Date:  2012-09-25       Impact factor: 3.240

10.  Evaluation of anterior segment parameters and possible influencing factors in normal subjects using a dual Scheimpflug analyzer.

Authors:  Xiaogang Wang; Jing Dong; Qiang Wu
Journal:  PLoS One       Date:  2014-05-16       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.