PURPOSE: Field of view and voxel resolution of cone beam computed tomography (CBCT) might affect the diagnostic capability. This study was performed to compare between the standard and HiRes zoom modes in the diagnosis of external root resorption (ERR) using CBCT. MATERIALS AND METHODS: Sixty three small cavities (0.25 mm depth and 0.5 mm diameter) were simulated on the buccal, lingual, and proximal surfaces at three different levels of 16 roots of teeth. After covering the root with nail varnish, the roots were inserted in the sockets and the model was placed in a water-containing lacuna. CBCT scans were taken in both standard and HiRes zoom modes using NewTom VG (QR srl Company, Verona, Italy). Then, an observer assessed the images to determine the presence or absence of the cavities. This process was repeated by increasing the size and depth of cavities to 0.5 mm depth and 1 mm diameter. Data were analyzed by McNemar test. The sensitivity, specificity, positive predictive value, negative predictive value, and likelihood ratio in evaluation of the simulated cavities were calculated. RESULTS: There was a significant difference between the two imaging modes in diagnosing the shallow cavities (p=0.02).The sensitivity of the standard zoom in detecting the shallow cavities was lower than that of the HiRes zoom. The likelihood ratio of the HiRes zoom was higher in the diagnosis of both cavity types. CONCLUSION: This study suggested that a smaller voxel size in the HiRes zoom mode of CBCT is preferred for diagnosis of ERR.
PURPOSE: Field of view and voxel resolution of cone beam computed tomography (CBCT) might affect the diagnostic capability. This study was performed to compare between the standard and HiRes zoom modes in the diagnosis of external root resorption (ERR) using CBCT. MATERIALS AND METHODS: Sixty three small cavities (0.25 mm depth and 0.5 mm diameter) were simulated on the buccal, lingual, and proximal surfaces at three different levels of 16 roots of teeth. After covering the root with nail varnish, the roots were inserted in the sockets and the model was placed in a water-containing lacuna. CBCT scans were taken in both standard and HiRes zoom modes using NewTom VG (QR srl Company, Verona, Italy). Then, an observer assessed the images to determine the presence or absence of the cavities. This process was repeated by increasing the size and depth of cavities to 0.5 mm depth and 1 mm diameter. Data were analyzed by McNemar test. The sensitivity, specificity, positive predictive value, negative predictive value, and likelihood ratio in evaluation of the simulated cavities were calculated. RESULTS: There was a significant difference between the two imaging modes in diagnosing the shallow cavities (p=0.02).The sensitivity of the standard zoom in detecting the shallow cavities was lower than that of the HiRes zoom. The likelihood ratio of the HiRes zoom was higher in the diagnosis of both cavity types. CONCLUSION: This study suggested that a smaller voxel size in the HiRes zoom mode of CBCT is preferred for diagnosis of ERR.
Authors: V P D Westphalen; I Gomes de Moraes; F H Westphalen; W D Martins; P H Couto Souza Journal: Dentomaxillofac Radiol Date: 2004-07 Impact factor: 2.419
Authors: Gabriela Salatino Liedke; Heloísa Emília Dias da Silveira; Heraldo Luis Dias da Silveira; Vinícius Dutra; José Antônio Poli de Figueiredo Journal: J Endod Date: 2009-02 Impact factor: 4.171
Authors: Carlos Estrela; Mike Reis Bueno; Ana Helena Gonçalves De Alencar; Rinaldo Mattar; José Valladares Neto; Bruno Correa Azevedo; Cyntia Rodrigues De Araújo Estrela Journal: J Endod Date: 2009-11 Impact factor: 4.171
Authors: Liliane Rosas Gomes; Marcelo Regis Gomes; João Roberto Gonçalves; Antônio Carlos O Ruellas; Larry M Wolford; Beatriz Paniagua; Erika Benavides; Lúcia Helena Soares Cevidanes Journal: Oral Surg Oral Med Oral Pathol Oral Radiol Date: 2015-10-20
Authors: Darren Forst; Simrit Nijjar; Carlos Flores-Mir; Jason Carey; Marc Secanell; Manuel Lagravere Journal: Prog Orthod Date: 2014-12-23 Impact factor: 2.750